Organizations: Industry 4.0 Convergence Bionics Engineering, Department of Biomedical Engineering, Pukyong National University, Busan 48513, Republic of Korea. · Smart Gym-Based Translational Research Center for Active Senior’s Healthcare, Pukyong National University, Busan 48513, Republic of Korea. · Digital Healthcare Research Center, Institute of Information Technology and Convergence, Pukyong National University, Busan 48513, Republic of Korea. · Ohlabs Corp., Busan, Republic of Korea.

Abstract

Image registration underpins measurement across scanning, camera, and microscopy imaging, yet a fundamental question is rarely posed: when is the sample-to-position map recoverable at all, and when does any estimator that reports a position necessarily fabricate one? We show that in reference-perturbed sampled imaging, where samples are localized through a perturbed reference, position fidelity (where samples land) and phase fidelity (which reference index becomes each block's origin) are logically independent: no policy acting on position information alone can guarantee phase fidelity. We derive a tight resolution threshold separating recoverable from provably-unidentifiable registration, and a recovery framework that certifies identifiable regions--recovering them exactly--while abstaining on provably-unidentifiable regions rather than hallucinating structure. On a deployed scanning system we measure a direction-bimodal registration offset consistent with the theory. Against classical and learned restoration baselines, certificate-free offset estimators fabricate structure on the unidentifiable regime, whereas the certified method abstains rather than fabricating. Finally, the certified-abstention mechanism carries across scanning, rolling-shutter, and cryo-electron-microscopy imaging--declining rather than fabricating on the regime it flags--though how completely it abstains and how tightly it bounds kept-region risk stay modality-specific (at extreme SNR the cryo-EM certificate abstains only partially): a structural-versus-statistical boundary in registration reliability.

Figures & tables

Explore similar work

Sep 25, 2026

Image Reconstruction from Phase with Untrained Neural Priors

Fourier phase encodes important spatial image structure, but recovering an image without measured spectral magnitude requires additional constraints and leaves absolute intensity ambiguous. We propose a projection-based two-stage framework that combines Fourier-phase and spatial-support constraints with an image-specific neural prior. The first stage alternates constraint enforcement with regularized neural-prior updates, while the second performs phase/support refinement alone with guaranteed convergence. We evaluate two neural-prior implementations on the same 77 microscopy images and compare them with a constraint-only baseline. After 500 final refinement passes, the best-performing variant achieves 31.41 dB pooled PSNR, 35.75 dB mean PSNR, and 0.9531 mean SSIM, improving pooled PSNR by 1.51~dB and reducing pooled MSE by 29.3% relative to the baseline. The results demonstrate the benefit of combining neural guidance with explicit constraint refinement at the evaluated iteration budget, while showing that lower phase residual alone does not guarantee greater reconstruction accuracy.
Sep 23, 2026

Recursive Uncertainty-Gated Image Registration for Learning-based Algorithms

Conventional image registration algorithms are robust to domain shifts and achieve low errors, but they are slow and computationally expensive. Deep-learning methods are efficient at inference-time, but face challenges in out-of-domain samples. We propose Recursive Uncertainty-Gated Image Registration (RUGI), an algorithm for iteratively refining deformation fields predicted by learning-based registration models. At each iteration, the registration model predicts an incremental deformation, and a gating map modulates the update. Refinements are hence concentrated in regions that remain difficult to register. We explore two gating strategies: a learned uncertainty-based approach and an image residual error approach. We evaluate RUGI on cardiac MRI and echocardiography datasets and show consistent improvements over single-step inference. Ablation experiments demonstrate that iterative refinement alone improves registration, but informative spatial gating provides a significant additional benefit. The error-gated variant of RUGI can also be applied directly to existing pretrained models; applied to VoxelMorph, TransMorph, and CycleMorph, it yields MSE reductions of 27-37% with no modification to the original training procedure. The improvements in registration performance are reflected in decreased errors in ejection fraction estimation relative to ground truths. These results demonstrate that spatially selective iterative refinement provides an effective strategy to improve registration accuracy at inference-time.
Jul 16, 2026

Hough-SIFT: Robust Image Registration for Linear Structures via Hough Space

Image registration is essential in applications such as electronic image stabilization. Scale-Invariant Feature Transform (SIFT), a widely used local keypoint detector and descriptor, typically provides accurate registration; however, it often fails in scenes with strong linear structures (e.g., shutters), where local features become ambiguous. We propose Hough-SIFT, a robust registration method that performs SIFT descriptor matching in Hough space. In this domain, linear structures form distinctive peaks that restore descriptor discriminability. Experiments demonstrate that Hough-SIFT is robust in linear scenes where SIFT frequently fails, while maintaining accuracy comparable to SIFT in normal scenes.