cs.CVNov 1, 2026

Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers

Authors: Sebastian Endt, Fatih Özkan, Marion I. Menzel

Organizations: AImotion Bavaria, Technische Hochschule Ingolstadt, Ingolstadt, Germany · TUM School of Computation, Information and Technology, Technical University of Munich, Germany · TUM School of Natural Sciences, Technical University of Munich, Germany

Abstract

T1-T2 correlation MRI has strong potential to quantify microstructural compartments without imposing a biological model. Traditionally, full T1-T2 spectra per voxel are reconstructed with an ill-conditioned and time-consuming Inverse Laplace Transform. We propose to view this challenge as an object detection task: A Detection Transformer (DETR) takes 64 TI/TE signals and directly predicts a set of compartments specified by T1, T2, and signal fraction. We achieve a mean average precision mAP@10 of 76.8% on simulated data, outperforming both our previous model design (53.8%) and regularized NNLS (66.1%). We show that our DETR approach outperforms NNLS in almost every setting across compartment count, compartmental signal fraction, and SNR. Reconstruction is orders of magnitude faster than NNLS. The results are fully reproducible from our public code: github.com/SebastianEndtTHI/t1t2-detr

Figures & tables

Explore similar work

Sep 30, 2026

Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers

Fiber orientation and compartmental microstructure are central to the characterization of white matter tissue in diffusion MRI, yet existing methods either resolve fiber orientations without quantifying microstructure, or quantify microstructure while assuming a fixed number of compartments and a single fiber direction. Nonparametric approaches that recover both require tensor-valued diffusion encoding and computationally expensive Monte-Carlo inversion of an ill-posed inverse Laplace transform. We propose to reframe this problem as an object detection-like task, adopting the Detection Transformer (DETR) architecture to jointly predict mean diffusivity (MD), fractional anisotropy (FA), main fiber direction, and signal fraction for a variable number of compartments per voxel from standard multi-shell diffusion MRI with linear encoding. Hungarian matching during training resolves permutation invariance across compartments. We introduce mean Average Precision as a reproducible benchmark metric. Evaluated on synthetic test data with up to five compartments per voxel, our model achieves R2=0.95R^2=0.95 for MD, R2=0.88R^2=0.88 for FA, and a median angular error of 4.2°, with performance scaling naturally with compartmental signal fraction.
Apr 1, 2026

Automated Detection of Multiple Sclerosis Lesions on 7-tesla MRI Using U-net and Transformer-based Segmentation

Ultra-high field 7-tesla (7T) MRI improves visualization of multiple sclerosis (MS) white matter lesions (WML) but differs sufficiently in contrast and artifacts from 1.5-3T imaging - suggesting that widely used automated segmentation tools may not translate directly. We analyzed 7T FLAIR scans and generated reference WML masks from Lesion Segmentation Tool (LST) outputs followed by expert manual revision. As external comparators, we applied LST-LPA and the more recent LST-AI ensemble, both originally developed on lower-field data. We then trained 3D UNETR and SegFormer transformer-based models on 7T FLAIR at multiple resolutions (0.5x0.5x0.5^3, 1.0x1.0x1.0^3, and 1.5x1.5x2.0^3) and evaluated all methods using voxel-wise and lesion-wise metrics from the BraTS 2023 framework. On the held-out test set at native 0.5x0.5x0.5^3 resolution, 7T-trained transformers achieved competitive overlap with LST-AI while recovering additional small lesions that were missed by classical methods, at the cost of some boundary variability and occasional artifact-related false positives. On a held-out 7 T test set, our best transformer model (SegFormer) achieved a voxel-wise Dice of 0.61 and lesion-wise Dice of 0.20, improving on the classical LST-LPA tool (Dice 0.39, lesion-wise Dice 0.02). Performance decreased for models trained on downsampled images, underscoring the value of native 7T resolution for small-lesion detection. By releasing our 7T-trained models, we aim to provide a reproducible, ready-to-use resource for automated lesion quantification in ultra-high field MS research (https://github.com/maynord/7T-MS-lesion-segmentation).
Oct 19, 2026

MoSAIK: Motion Search with Artificial Intelligence in K-space

Object: Motion artefacts remain a major limitation of routine two-dimensional T2-weighted turbo spin-echo (TSE) brain MRI, reducing diagnostic confidence and often necessitating repeated acquisitions. MoSAIK (Motion Search with AI in K-space) retrospectively estimates in-plane rigid-body motion directly from standard multi-coil TSE k-space. Without a motion-free reference, external navigators, or additional acquisitions, MoSAIK infers motion from k-space self-consistency violations and incorporates predicted parameters into model-based, motion-aware reconstruction rather than synthesizing corrected images. Materials and Methods: Selected complex coil data were represented as log-magnitude and phase channels. A decoupled convolutional embedding and Transformer encoder estimated phase-encoding-line-indexed rotation and two-dimensional translations. Training used motion-free clinical acquisitions with simulated motion; four held-out subjects were evaluated. Component-wise errors assessed estimation; SSIM and PSNR in silico and entropy focus criterion (EFC) in vivo assessed reconstruction. Results: Motion estimation errors were low for both rotation (MSE << 0.2 deg2^2) and translation (MSE << 0.2 pixels2^2), with Pearson correlations of approximately 0.96 and 0.94, respectively. In every in-vivo acquisition, more than 75% of slices showed information gain relative to uncorrected reconstructions. MoSAIK reduced visible artefacts while preserving anatomical detail. Discussion: Transformer-based k-space motion-trajectory estimation enables fast retrospective correction of standard clinical TSE brain MRI.