cs.LGNov 1, 2026

Robust Remote ECG Monitoring under Energy Constraints: Anomaly Filtering versus Predictive Uncertainty

Authors: Mustafa Fuad Rifet Ibrahim, Maurice Meijer, Alexander Schlaefer, Peer Stelldinger

Organizations: CTO System Innovation, NXP Semiconductors Germany GmbH, Beiersdorfstraße 12, Hamburg, 22529, Germany · Institute of Medical Technology and Intelligent Systems, Hamburg University of Technology, Am Schwarzenberg-Campus 1, Hamburg, 21073, Germany · Faculty of Computer Science and Digital Society, Hamburg University of Applied Sciences, Berliner Tor 5, Hamburg, 20099, Germany · Business Line Secure Connected Edge, NXP Semiconductors, High Tech Campus 60, Eindhoven, 5656, The Netherlands

Abstract

Machine learning for remote electrocardiogram monitoring must handle noise and diseases absent from training under tight resource constraints. We investigate whether upstream unsupervised anomaly detection can improve monitoring decisions more efficiently than classifier-derived uncertainty. We evaluate five detectors on PTB-XL and BUT QDB and compare a two-stage filter-classifier system with Monte Carlo Dropout and deep ensembles under unseen-disease and noise conditions. Performance is averaged over five training seeds. We measure single-pass energy, latency, and graph memory on a microcontroller's central processing unit (CPU) and neural processing unit (NPU). Per-score neural network costs account for repeated evaluations but exclude scoring outside deployed graphs. Energy equations relate filtering and rejection to avoided classifier execution. Across four disease scenarios, Deep Support Vector Data Description (Deep SVDD) achieves the highest mean area under the receiver operating characteristic curve within all tested finite CPU energy budgets. On the NPU, it leads at 1 mJ, while Monte Carlo Dropout has slightly higher means at 10 and 100 mJ. With a narrow CPU classifier, the Deep SVDD two-stage system increases the fraction of correctly classified or correctly rejected inputs by 15.0-19.4 percentage points over classification without rejection. Estimated energy per input is 1.93-6.99 mJ, compared with 52.53 mJ for Monte Carlo Dropout and 8.76-17.51 mJ for deep ensembles, at each method's retrospectively selected test accuracy peak. These results support upstream filtering for efficient remote monitoring, while independent validation and complete-system measurements remain necessary.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jun 10, 2026

Privacy-Preserving Federated Autoencoder for ECG Anomaly Detection on Edge Devices

Continuous electrocardiography (ECG) monitoring could surface rhythm abnormalities before they escalate into cardiovascular events. However, a deployable system must satisfy three requirements simultaneously: legal-grade privacy (GDPR, HIPAA), real-time inference on constrained edge hardware, and detection quality under non-IID cross-hospital data. We design and evaluate an end-to-end federated system addressing all three for unsupervised 12-lead ECG anomaly detection on PTB-XL dataset, combining three autoencoder families (VanillaAE, ConvAE, VAE), Flower-based federated averaging (FedAvg) across ten simulated hospitals, client-side differentially private SGD (DP-SGD) with a Rényi-DP accountant, and 8-bit integer (INT8) post-training quantization with Raspberry Pi 4 benchmarking. Our main contributions are: an empirical characterization of how these mechanisms compose, practical DP-specific recommendations, and technical and security insights for a clinically sensitive setting. Federated learning matches or exceeds the centralized baseline across all architectures (ConvAE federated area under the ROC curve, AUROC, 0.7820.782), and an ε\varepsilon sweep identifies ε=4\varepsilon=4 as the recommended clinical operating point. INT8 quantization roughly halves model size and cuts Pi 4 latency by up to 4444% with <0.12<0.12% AUROC loss. Crucially, DP and quantization penalties are empirically independent, so practitioners need not trade a strong privacy guarantee for a compact edge footprint. To our knowledge, this is the first system combining federated learning, formal (ε,δ)(\varepsilon,δ)-DP, unsupervised reconstruction-based detection, and quantized AArch64 deployment.
Feb 18, 2026

UCTECG-Net: Uncertainty-aware Convolution Transformer ECG Network for Arrhythmia Detection

Deep learning has improved automated electrocardiogram (ECG) classification, but limited insight into prediction reliability hinders its use in safety-critical settings. This paper proposes UCTECG-Net, an uncertainty-aware hybrid architecture that combines one-dimensional convolutions and Transformer encoders to process raw ECG signals and their spectrograms jointly. Evaluated on the MIT-BIH Arrhythmia and PTB Diagnostic datasets, UCTECG-Net outperforms LSTM, CNN1D, and Transformer baselines in terms of accuracy, precision, recall and F1 score, achieving up to 98.58% accuracy on MIT-BIH and 99.14% on PTB. To assess predictive reliability, we integrate three uncertainty quantification methods (Monte Carlo Dropout, Deep Ensembles, and Ensemble Monte Carlo Dropout) into all models and analyze their behavior using an uncertainty-aware confusion matrix and derived metrics. The results show that UCTECG-Net, particularly with Ensemble or EMCD, provides more reliable and better-aligned uncertainty estimates than competing architectures, offering a stronger basis for risk-aware ECG decision support.
Jun 13, 2026

ECG-LDC: A Hardware-Efficient Low-Dimensional Computing Framework for ECG Arrhythmia Classification

Continuous cardiac monitoring in wearable devices demands classifiers that are simultaneously accurate, energy-efficient, and deployable on resource-constrained hardware. While deep neural network approaches have demonstrated high classification accuracy for electrocardiogram (ECG) arrhythmia detection, their substantial parameter counts and reliance on multiply-accumulate-intensive operations make them impractical for low-cost edge platforms. In this work, we propose ECG-LDC, a hardware-software co-design framework that adapts Low-Dimensional Computing (LDC) for real-time ECG arrhythmia classification. ECG-LDC employs a dual-encoder architecture with dedicated value and feature codebooks to independently encode morphological waveform features and RR-interval temporal features, enabling effective capture of both intra-beat and inter-beat cardiac dynamics. The framework encompasses data preprocessing, model training, and a hardware accelerator architecture prototyped on the Pynq-Z2 platform. Implemented using binary representations and XOR/XNOR-based operations, ECG-LDC achieves 97.18%97.18\% accuracy with a memory footprint of only 3.86 kB3.86\ \text{kB}. ECG-LDC sacrifices approximately 1.8%1.8\% accuracy versus SOTA TinyML classifiers but achieves 1111~570× 570\times reduction in memory usage; among FPGA-based five-class arrhythmia classifiers, it delivers the highest accuracy with up to 2.4×2.4\times fewer LUTs and zero DSP block utilization, affirming its suitability for real-time arrhythmia detection on resource-constrained wearable platforms.