cs.LGNov 1, 2026

METER: Matched-Event Calibration for Short-Event EEG Microstate Transition Analysis

Authors: Abdul Basit, Eklavya Tomar, Muhammad Shafique

Organizations: eBRAIN Lab, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates. · Dubai College, Dubai, United Arab Emirates.

Abstract

Short cognitive events contain unequal and often sparse transition evidence, so raw EEG microstate distances can reflect finite sampling rather than neural reconfiguration. We introduce METER (Matched-Event Transition Estimation against a Reference), a participant-relative framework that separates marginal occupancy from conditional next-state choice and evaluates each event against duration-conditioned events from a fixed participant-specific reference bank. METER-Jump integrates uncertainty in sparse target and reference transition tables, returning a randomized event rank for testing and a continuous standardized coordinate for association analysis. Using a reproducible three-state representation selected by spatial criteria, we evaluated METER with participant-fitted simulations, estimator ablations, map perturbations, and preprocessing sensitivities. Event-level false-positive rates were 0.044-0.056 across four heterogeneous null mechanisms. By contrast, global cutoffs learned under the participant-fitted null and transferred unchanged to other regimes produced false-positive rates from 0.004 under rare transitions to 0.234 under map perturbation; duration-conditioned ranks remained near 0.05. Detection probability was approximately 0.69 with fixed maps but fell to 0.22 after bootstrap-derived map-assignment perturbation. In 4,175 natural-reading events from 18 participants, no linguistic association survived multiplicity correction in the primary 30-ms analysis, although a 20-ms sensitivity changed one within-stream max-TT decision. METER therefore calibrates finite-event departures conditional on a defined microstate sequence, while map assignment, filtering, temporal smoothing, and reference construction remain separate sources of measurement uncertainty.

Figures & tables

Explore similar work

May 19, 2026

Atoms of Thought: Universal EEG Representation Learning with Microstates

Learning universal representations from electroencephalogram (EEG) signals is a cutting-edge approach in the field of neuroinformatics and brain-computer interfaces (BCIs). Conventionally, EEG is treated as a multivariate temporal signal, where time- or frequency-domain features are extracted for representation learning. This paper investigates a simple yet effective EEG representation, i.e., microstates. Microstates represent the building blocks of brain activity patterns at a microscopic time scale. We build a universal microstate tokenizer from a large medical EEG dataset by clustering continuous EEG signals into sequences of discrete microstates. The microstate tokenizer is then adopted universally across a series of downstream tasks, including sleep staging, emotion recognition, and motor imagery classification. Experimental results show that EEG representation learning with microstates outperforms traditional time-domain and frequency-domain features under different models and across different tasks. Further analysis shows that microstates offer greater interpretability and scalability, thereby opening up applications in both cognitive neuroscience and clinical research.
Sep 26, 2026

Measurement-Gated Provenance Attenuation for Frozen EEG Representations

Frozen EEG representations retain acquisition signatures as well as neural activity. Source predictability alone does not identify what should be removed: it can reflect measurement effects or genuine biological and population differences, which should not be erased. We propose Measurement-Gated Provenance Attenuation (MGPA), built on one principle: measurement evidence determines where correction may act, and preserved information determines what it should aim for. Paired measurement contrasts define a gate outside which nothing changes; inside it, the source score is moved to the value the preserved coordinates already predict: for a fixed affine score, this keeps the same information as any target set by those coordinates and needs the least expected squared movement. Closed-form and critic-guided iterative constructions apply it without source identity or encoder retraining. Three studies test the principle at increasing distance from its assumptions. Under controlled reference changes, where the source-task association is known, MGPA brings source to near chance with task performance unchanged, whereas erasing what predicts source (LEACE) lowers frozen-task AUROC from .753 to .656 while barely touching source; ablations attribute the attenuation to the gate's directions and 2.7x less movement to the conditional target. Across recordings from different devices and electrodes, iterative correction lowers source accessibility while preserving or improving task performance. Finally, one iterative map selected on one task and reused unchanged on existing heads for two others raises their worst-association AUROC (lowest over device-label shifts) by .057 and .019 over LEACE, at a cost to those heads while the training association holds. A reusable correction shows its value in how an existing predictor behaves once acquisition cues stop being reliable, not only in what a probe can read.
May 11, 2026

DANCE: Detect and Classify Events in EEG

Event identification in continuous neural recordings is a critical task in neuroscience. Decoding in EEG is dominated by classifying windows aligned to known event onsets. However, while available in controlled experiments, such onsets are absent in continuous real-world monitoring. Here, we introduce DANCE, a deep learning pipeline that frames neural decoding as a set-prediction problem and jointly detects and classifies events directly from raw, unaligned signals. Evaluated separately on ten datasets curated from the literature with a wide variety of event types (ranging from milliseconds to minutes in duration), our model outperforms existing methods on a broad range of cognitive, clinical and BCI tasks. This single architecture establishes a new state of the art in the competitive task of seizure monitoring and matches the accuracy of onset-informed models for BCI tasks. Overall, our method marks a step towards end-to-end asynchronous neural decoding models