cs.RONov 6, 2026

Robust Readout of Cross-Point Resistive Arrays via Time-Domain Optimization

Authors: Taro Tako, Hiroshi Kaminaga, Taisuke Kobayashi

Organizations: National Institute of Informatics (NII) and with The Graduate University for Advanced Studies (SOKENDAI), 2-1-2 Hitotsubashi, Chiyoda-ku, Tokyo, 101-8430, Japan · CNRS-AIST JRL (Joint Robotics Laboratory), IRL 3218, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan

Abstract

Cross-point resistive arrays are attractive for high-density tactile sensing because they reduce wiring complexity. However, conventional frequency-based readout methods can become inaccurate in robotic sensing environments, where long interconnects and measurement and environmental noise degrade the observed signals. We propose a time-domain optimization method for robust readout of cross-point resistive arrays. The method determines resistance values by fitting a time-domain observation model to the measured waveform over the interval, rather than relying solely on spectral amplitudes. By exploiting the full waveform, the proposed method improves robustness under noisy observation conditions. In simulations of a 16 x 16 array, the proposed method reduced the mean readout error by 20% compared with the baseline method. Furthermore, validation over 1,000 trials showed that the proposed method achieves more robust estimation than the conventional method, reducing the mean error and standard deviation by 24.6% and 77.6%, respectively. The improvement was also confirmed in cross-point array simulations with resistance distributions emulating tactile sensor responses.

Figures & tables

Explore similar work

Jun 9, 2026

HiPi: Reproducible High-Fidelity Piezoresistive Sensors for Robotic Manipulation

Piezoresistive tactile sensors are attractive for robotic manipulation because they are thin, lightweight, low-cost, and scalable to dense large-area sensing. However, existing systems still face a practical trade-off: recent reproducible designs emphasize accessibility and ease of reproduction, whereas high-fidelity readout architectures remain more difficult to fabricate, assemble, and deploy. We present HiPi, a reproducible high-fidelity piezoresistive sensing system for robotic manipulation. Building on a low-crosstalk readout principle, HiPi redesigns the complete hardware stack around reproducibility, deployability, and multi-sensor scalability. The system includes a compact readout PCB compatible with commercial PCB fabrication and assembly services, eliminating manual soldering; a smaller and lower-cost STM32-based MCU module; an optimized communication pipeline that achieves 220 Hz readout in a bimanual setup with four dense tactile arrays (2048 taxels in total); and FPCB-based conductive layers that simplify sensor fabrication and stacking. Experiments with structured 3D-printed contact patterns show that HiPi preserves contact geometry substantially better than a reproducible baseline, improving the average IoU from 0.428 to 0.797 and the average Dice score from 0.539 to 0.886. These results suggest that HiPi bridges an important gap between reproducible fabrication and high-fidelity readout, making dense piezoresistive tactile sensing more practical for bimanual manipulation and multi-fingered robotic systems.
May 2, 2026

High-Speed, Scalable Sensor Readout for Dexterous Robotic Hands via Shift-Register Multiplexing

Dexterous robotic hands require high-speed multimodal sensing across many degrees of freedom, yet existing readout architectures often impose trade-offs between sensor count, wiring complexity, and sampling bandwidth. This paper presents a scalable analog sensor readout architecture based on a serial-in parallel-out (SIPO) shift-register principle. The proposed architecture supports versatile integration of heterogeneous analog-output sensors, scalable expansion using only three signal lines between sensor modules, and fast, configurable sampling. We validate the approach on a tendon-driven robotic hand integrating 16 joint sensor modules and one four-channel tactile sensor module, enabling acquisition of 20 sensor channels at a full-scan rate of 1 kHz, with stable operation up to 1.5 kHz. Joint sensor characterization showed a maximum slope absolute percentage error (APE) of 0.446% and sub-degree estimation error, indicating that the proposed readout system preserves sensing performance. For tactile sensing, LSTM-based models enabled real-time force estimation and contact-location classification at 1 kHz. System-level experiments showed that the joint sensors provided more accurate feedback than motor-based estimation during interaction. Closed-loop experiments further demonstrated improved joint trajectory tracking using joint-sensor feedback and force-controlled object pinching using tactile feedback. The proposed architecture offers a practical path toward sensorized robotic hands for dexterous manipulation.
Nov 17, 2026

LuxTac: A Flexible, Scalable, and Open-Source Optical Taxel Array with Distributed Three-Axis Force Sensing for Tactile Robot Learning

Low-cost tactile arrays have made touch a practical input for robot learning, but piezoresistive designs sense only pressure, while camera-based sensors that also resolve shear are too bulky to tile over a gripper. To solve this problem, we present LuxTac, a flexible, scalable optical taxel array, about 3.5 mm thick and built from off-the-shelf parts. Each taxel is a digital RGBC light-to-digital converter under a translucent white silicone layer capped by an opaque black film, so the back-scattered LED light falls monotonically with local indentation depth. The same board accepts two interchangeable gel cartridges: a plain one for normal sensing, and one with colored walls that encodes the local shear in the color of the returned light, with no camera, magnets, or bump overlay, making LuxTac, to our knowledge, the first optical taxel array to resolve shear at individual taxels. Characterized with an automated CNC indenter and a six-axis force/torque sensor, the normal cartridge responds linearly to force (R2R^2 = 0.999) from 104 mN to at least 5.8 N, with 2.0% repeatability, 5.9% hysteresis, and a taxel-to-taxel variation of 6-10% after normalization. With the shear cartridge, per-taxel models estimate the three-axis force at every taxel; across three indenter shapes and nine held-out sessions, the summed estimates reach R2R^2 = 0.96/0.96/0.92 in x/y/z, each taxel's estimate 0.92/0.93/0.94, and the median shear-direction error is 4.8 degrees. Adding LuxTac pressure readings to an Action Chunking Transformer policy substantially improves peg-in-hole success over a vision-only baseline. Design files, code, and videos are available at https://luxtac.github.io.