cs.CVNov 7, 2026

3D Segmentation in the Clinic: A Grand Challenge

Authors: Bram van Ginneken, Tobias Heimann, Martin Styner

Organizations: Image Sciences Institute, University Medical Center Utrecht, The Netherlands · Medical and Biological Informatics, German Cancer Research Center, Heidelberg, Germany · Departments of Psychiatry and Computer Science, University of North Carolina at Chapel Hill, USA

Abstract

This paper describes the set-up of a segmentation competition for automatic and semi-automatic extraction of the liver from computed tomography scans and the caudate nucleus from brain MRI data. This competition was held in the form of a workshop at the 2007 Medical Image Computing and Computer Assisted Intervention conference. The rationale for organizing the competition is discussed, the training and test data sets for both segmentation tasks are described and the scoring system used to evaluate the segmentation is presented.

Figures & tables

Explore similar work

May 15, 2026

TriALS: Triphasic-Aided Liver Lesion Segmentation Benchmark in Non-Contrast CT

Automated segmentation of liver lesions on non-contrast computed tomography (NCCT) is clinically important but fundamentally challenging, particularly in low-resource settings across Africa and Asia where contrast agents are frequently unavailable. Progress has been limited by the absence of annotated NCCT benchmarks. Here we describe the TriALS challenge for automated liver lesion segmentation under contrast-limited conditions, supported by a multi-centre dataset of 150 cases with four-phase CT acquisitions (600 volumes) from Egyptian and Chinese institutions. Algorithms were evaluated on 70 cases from three institutions, including an independent external cohort. The top-performing method achieved a mean venous-phase Dice of 0.754, consistent with human-level performance, yet dropped to 0.57 on NCCT. On external validation, the leading method outperformed off-the-shelf models by up to 28% in Dice on NCCT. Algorithm performance was most strongly predicted by training data scale and pre-training strategy. A cross-year comparison exposed a persistent perceptual barrier on NCCT that scaling pre-training alone cannot overcome. Data, annotations, and code are available at https://github.com/xmed-lab/TriALS.
Jul 30, 2026

A Unified Benchmark of Deep Learning Models for Multi-task 3D Brain Tumor Segmentation from Magnetic Resonance Imaging

Automatic brain tumor segmentation from magnetic resonance imaging (MRI) has become a fundamental task in computer-assisted diagnosis, treatment planning, and disease monitoring. Although numerous deep learning architectures have recently been proposed, objective comparisons remain challenging because published studies often employ different datasets, preprocessing strategies, training protocols, and evaluation procedures. This work presents a unified experimental benchmark for comparing representative convolutional neural networks (CNNs), Transformer-based models, and recent State Space Model (SSM) architectures under homogeneous experimental conditions. Five state-of-the-art three-dimensional segmentation models, including 3D U-Net, SegResNet, Swin UNETR, SegMamba, and SegMambaV2, are evaluated on two brain tumor segmentation datasets representing distinct clinical scenarios: intracranial meningioma segmentation (BraTS 2023) and post-treatment glioma segmentation (BraTS 2024). All architectures are trained using identical preprocessing, data augmentation, optimization strategies, and evaluation protocols to ensure a fair comparison. Performance is assessed using segmentation accuracy metrics together with computational cost indicators, including inference time and the size of each model. The results provide practical insights into the trade-offs between segmentation accuracy and computational efficiency, highlighting the suitability of different architectural paradigms for challenging three-dimensional brain tumor segmentation tasks.
Sep 27, 2026

Parameter-Efficient 3D Segmentation of Liver and Liver tumors: Depthwise factorization Scales Better Than Dense Convolution with Spatial Dimensionality

Three-dimensional dense convolutional networks are the strongest performers on volumetric medical image segmentation, but their parameter counts scale poorly: moving a dense k x k convolution to k x k x k multiplies its weights by k. We observe that depthwise separable factorization does not share this penalty. Because the cubic kernel term applies only to the depthwise stage while the pointwise projection, which dominates the parameter count, is unchanged, the same architecture grows by 5 % from 2D to 3D where a dense convolutional U-Net grows by 200 %. We exploit this asymmetry to build a 3D U-Net with 536,990 parameters, 24x fewer than an identical dense 3D U-Net. On MSD Task03 Liver (the Medical Segmentation Decathlon liver task, derived from LiTS), evaluated per case under five-fold cross-validation over all 131 public volumes, the model reaches a tumor Dice of 0.577 (95% CI [0.518, 0.633]) and a liver Dice of 0.947 (95% CI [0.941, 0.952]). Its liver Dice exceeds previously reported performance. Its tumor Dice exceeds their low-resolution configuration (0.4701) by 0.107 and their 2D configuration (0.5394), at approximately one twenty-fourth of the parameters and roughly half the in-plane resolution. Trained under identical conditions on a common held-out split, it exceeds a dense 3D U-Net on liver by +0.031 Dice (paired p = 0.006) and on tumor by +0.041 (95 % CI [+0.005, +0.081], paired p = 0.056), suggesting the factorization also acts as a regularizer in the small-data regime characteristic of medical imaging. We further show, on both LiTS and a 2D endoscopy benchmark, that a large fraction of the network's learnable spatial filters can be replaced by fixed shifts at no cost in accuracy, but that replacing all of them is measurably worse, the placement of spatial capacity matters more than its total amount.