cs.LGNov 7, 2026

Interpretable Cyber-Physical Attack Detection in Smart Grids: A Leakage-Controlled Multi-Testbed Evaluation of Fusion, Robustness, and Observability Limits

Authors: Muhammad Ridwanul Hoque, Sarah Sharif, Reza Saeed Kandezy, Yaser Banad

Organizations: Intelligent Neuromorphic and Quantum Understanding for Innovative Research and Engineering (INQUIRE) Laboratory, Norman, 73019, Oklahoma, U.S.A. · School of Electrical and Computer Engineering, University of Oklahoma, Norman, 73019, Oklahoma, U.S.A.

Abstract

Cyber-physical smart-grid detectors are typically treated as black boxes and validated exclusively on clean, temporally shuffled datasets, which risk overly optimistic performance claims. This work presents a multi-testbed evaluation study built around an interpretable, time-windowed fusion Random Forest, adopting the pessimistic result whenever evaluation protocols disagree. (i) On a public paired cyber-physical dataset, shuffled cross-validation is optimistic: macro-F1 falls from 0.96 to 0.88 +/- 0.06 under rolling-origin temporal evaluation. A topology-free graph convolutional network (GCN) serving as a control confirms that this lightweight model is competitive on these splits. (ii) The adaptive and adaptive-joint feature-space attacks, which are infeasible as realistic grid manipulations, degrade macro-F1 to 0.67 and 0.34, respectively. Adversarial training and randomized smoothing partially restore performance, and a physics-constrained evolution-strategy evasion on the IEEE 14-Bus testbed shows the same vulnerability pattern. (iii) On real IEC-104 traffic, the cyber view reliably catches structural attacks (recall of 0.87 to 0.98) but largely fails on semantic value manipulation (recall of 0.11 to 0.35). An observability taxonomy on the IEEE 14-Bus system reveals that stealthy false data injection defeats all three observation views. (iv) On a full AC weighted least-squares state-estimation testbed, a forecasting-aided temporal test is evaded by slow ramps precisely where a rate-invariant physics-manifold test sustains detection at a common 5% false-alarm target. A full end-to-end evaluation on IEEE 118-Bus confirms the ordering but bounds its strength: the manifold test detects every trial down to 0.05 degree/step and 0.48 at 0.02 degree/step, against 0.14 for the temporal test. All code and benchmarks are released.

Figures & tables

Appendix figures & tables5 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. Cyber-Physical Anomaly Detection in IoT-Enabled Smart Grids Using Machine Learning and Metaheuristic Feature Optimization

    May 21, 2026Adis Alihodžić, Eva Tuba, Milan TubaCyber-Physical SystemsCybersecurity

  2. Stealthy, High-Impact False Data Injection Attacks in Smart Grid Using Physics-Constrained GAN with Limited System Knowledge

    Nov 11, 2026Md. Mainul Islam, Hasan Kurban, Abdulrahman Takiddin +3power system state estimationFalse Data Injection Attacks