Enhancing Balance and Posture in Material Handling Tasks with a Wearable Robotic Tail
Authors: Eisa Anwar, Sajeeva Abeywardena, Stuart C. Miller, Ildar Farkhatdinov
Organizations: Faculty of Natural, Mathematical and Engineering Sciences, King’s College London, London, UK. · School of Electronic Engineering and Computer Science, Queen Mary University of London, London, UK. · School of Mechanical Engineering Sciences, University of Surrey, UK. · William Harvey Research Institute, Queen Mary University of London, London, UK. · School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
Frequent heavy lifting is linked to musculoskeletal strain, with lower back pain affecting up to 40% of manual labourers. Inspired by animals using tails for balance, we developed a wearable robotic tail as a dynamic counterbalance. Ten participants performed an imitated shelf loading/unloading task across three conditions: active tail, passive tail, and no tail. Kinematics, centre of pressure, and muscle activation (gastrocnemius, erector spinae, tibialis anterior, biceps brachii) were measured. Compared with no tail, the active tail achieved >20 mm reduction in centre of pressure peak displacement, 4.3 degree reduction in trunk motion, and >9% and >20% reductions in erector spinae and gastrocnemius activity, respectively. The passive tail produced smaller reductions, suggesting passive counterbalancing helps while active movement augments it further. Biceps brachii activation increased with the active versus passive tail. The ankle kinematics and tibialis anterior activation were unchanged. These findings support wearable robotic tails for improving balance during material handling.
Figures & tables
Figure 1: Robotic tail The custom built wearable robot tail worn by a user during object handling task.
Figure 2: Centre of Pressure (CoP) Analysis. ( A ) CoP change for one participant for the placement and retrieval trials for all conditions of the experiment. The blue, green, and orange lines represent the active tail (ACT), passive tail (PAS), and without tail (WOUT) conditions respectively, while the static standing (STND) trial is shown in yellow. The grey lines at the top and bottom of the figure mark the boundaries of the BoS (i.e., the front and back of the feet). ( B ) Peak displacement and RoM of the sagittal CoP for all participants. Each participant is represented by a single colour, and each point represents the average of all their repetitions for a single condition. The percentage changes of the statistically significant results are stated, and asterisks indicate the significance level: *( p<0.05 ), **( p<0.01 ), ***( p<0.001 ).
Figure 3: Trunk and ankle inclination (i.e. flexion/extension). ( A ) Single participant for the placement and retrieval trials for all conditions of the experiment. The single yellow line represents the static standing baseline result and the three other colours with multiple repetitions represent the three different conditions. ( B ) Trunk and ankle inclination for all participants. Each participant is represented by a single colour, and each point represents the average of all their repetitions for a single condition. Dotted lines link a single participant across their experimental conditions. The percentage values of the statistically significant results are shown under respective graphs.
Figure 4: Muscle Activity Data. ( A ) Muscle activity of one participant for all conditions and repetitions. The left four graphs are for each of the four recorded muscles for the placement task and the right four graphs are for the retrieval task. ( B ) Muscle activity for all participants for all conditions. Each condition’s repetitions are averaged for each individual point. The data is split into four rows with two columns. The left graphs are for placement and the right graphs are for retrieval tasks. Each row corresponds to one of the four muscles tested: biceps brachii (BB), erector spinae (ES), gastrocnemius (GS) and tibialis anterior (TA). Each section of the three graphs consists of peak activity, average activity and iEMG result.
Figure 5: Experimental Setup. ( A ) The setup of the experiment and the sensors used. The light blue circles are motion tracking markers, the darker blue rectangles are electromyography sensors (EMG), and the dark blue line the figure is standing on is a force plate. ( B ) The experimental procedure consisting of two tasks. ( C ) The experiment was carried out in three conditions: with the tail powered and active (ACT), with the tail unpowered and passive (PAS), and without the tail (WOUT).
The decline of human balance control due to aging and pathological conditions increases fall risk, a major concern in geriatric care and rehabilitation. Gait training is essential for balance recovery, enhancing walking ability and postural control. However, existing overground robotic gait trainers have limitations: body weight support systems are bulky and impractical for daily use, while end-effector-based systems often compromise transparency, altering natural gait dynamics. This paper presents the Dynamic Robotic Balance Assistant (DRBA), a novel gait trainer providing assist-as-needed body weight and balance support for various training scenarios. DRBA integrates a 3-degree-of-freedom (3-DoF) robotic arm for pelvic support with flexible motion, a compact sit-to-stand assistance module, and user-following and fall detection algorithms to ensure minimal interference and responsive support. Experimental results demonstrated high transparency, with minimal impact on natural gait dynamics. A patient trial with nine elderly patients with varying medical conditions and balance impairments (ranging from severe to mild) further validated DRBA's effectiveness. The results showed that DRBA-assisted training increased step length and walking speed compared to therapist-assisted gait training. Additionally, DRBA enabled users to perform tasks beyond their unaided ability, expanding rehabilitation possibilities. These findings highlight DRBA's potential to enhance rehabilitation outcomes by facilitating higher training intensity and enabling task-oriented exercises.
Yifan Wang, Li Li, Youlong Wang +9
School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798 Singapore
Supernumerary robotic limbs (SLs) have the potential to transform a wide range of human activities, yet their usability remains limited by key technical challenges, particularly in ensuring safety and achieving versatile control. Here, we address the critical problem of maintaining balance in the human-SLs system, a prerequisite for safe and comfortable augmentation tasks. Unlike previous approaches that developed SLs specifically for stability support, we propose a general framework for preserving balance with SLs designed for generic use. Our hierarchical three-layer architecture consists of: (i) a prediction layer that estimates human trunk and center of mass (CoM) dynamics, (ii) a planning layer that generates optimal CoM trajectories to counteract trunk movements and computes the corresponding SL control inputs, and (iii) a control layer that executes these inputs on the SL hardware. We evaluated the framework with ten participants performing forward and lateral bending tasks. The results show a clear reduction in stance instability, demonstrating the framework's effectiveness in enhancing balance. This work paves the path towards safe and versatile human-SLs interactions. [This paper has been submitted for publication to IEEE.]
Older adults are particularly susceptible to falls following perturbations during standing, such as forward loss of balance. Back support devices that assist trunk extension may help mitigate fall risk by preventing excessive trunk flexion. Previous studies have investigated heavy back support devices; however, these systems often introduced adverse effects on stability due to their added mass, which shifted the body's natural center of mass unfavorably. In contrast, lightweight passive devices have shown limited benefits, as they can generate only modest assistive forces during the relatively small trunk flexion associated with forward balance loss. In this study, we evaluated the effects of a lightweight semi-active soft back support device on postural stability following standing perturbations. Our device combines an active element (a pneumatic artificial muscle) in parallel with a passive elastic band. The active element rapidly provides assistive force following a perturbation, overcoming the limitations of passive devices. Experiments conducted with five healthy individuals demonstrated that the semi-active device significantly reduced whole-body angular momentum and increased the margin of stability, indicating improved balance recovery performance. These results highlight the promise of semi-active soft wearable robots as an effective and lightweight strategy for fall prevention during standing perturbations.
Rohan Khatavkar, Jiefeng Sun, Hyunglae Lee