cs.CVNov 9, 2026

Calibrated Alarm Thresholds for Compact Fire and Smoke Detectors

Authors: Vikas Sandireddy

Organizations: California, USA

Abstract

Compact object detectors such as YOLOv8n are a common choice for camera-based fire and smoke detection on low-power devices. These detectors are usually evaluated with box-level metrics such as mean average precision, and their outputs are turned into decisions with a fixed confidence threshold such as 0.25 or 0.5. A fire monitoring system, however, makes one decision per image: raise an alarm or not. In this paper we evaluate two publicly available compact detectors on the D-Fire test set at the image level. We compare three simple rules for turning box detections into one alarm score per image, and we use a split conformal procedure to choose the alarm threshold from held-out images so that the expected fraction of missed fire and smoke images stays below a chosen target. We find that the same fixed threshold leads to very different miss rates for the two detectors, 17.3 and 8.4 percent at a threshold of 0.5, while the calibrated threshold meets miss-rate targets of 10, 5 and 1 percent for both detectors and all three rules. At a 5 percent target, the false alarm rate on images without fire or smoke stays between 1.2 and 3.0 percent. We also find that smoke-only images stay below the target even when the overall target is met, and we describe the main failure cases.

Figures & tables

Explore similar work

Mar 25, 2026

Towards automatic smoke detector inspection: Recognition of the smoke detectors in industrial facilities and preparation for future drone integration

Fire safety consists of a complex pipeline, and it is a very important topic of concern. One of its frontal parts are the smoke detectors, which are supposed to provide an alarm prior to a massive fire appears. As they are often difficult to reach due to high ceilings or problematic locations, an automatic inspection system would be very beneficial as it could allow faster revisions, prevent workers from dangerous work in heights, and make the whole process cheaper. In this study, we present the smoke detector recognition part of the automatic inspection system, which could easily be integrated to the drone system. As part of our research, we compare two popular convolutional-based object detectors YOLOv11 and SSD widely used on embedded devices together with the state-of-the-art transformer-based RT-DETRv2 with the backbones of different sizes. Due to a complicated way of collecting a sufficient amount of data for training in the real-world environment, we also compare several training strategies using the real and semi-synthetic data together with various augmentation methods. To achieve a robust testing, all models were evaluated on two test datasets with an expected and difficult appearance of the smoke detectors including motion blur, small resolution, or not complete objects. The best performing detector is the YOLOv11n, which reaches the average [email protected] score of 0.884. Our code, pretrained models and dataset are publicly available.
Mar 10, 2026

Intelligent Spatial Estimation for Fire Hazards in Engineering Sites: An Enhanced YOLOv8-Powered Proximity Analysis Framework

This study proposes an enhanced dual-model YOLOv8 framework for intelligent fire detection and proximity-aware risk assessment, extending conventional vision-based monitoring beyond simple detection to actionable hazard prioritization. The system is trained on a dataset of 9,860 annotated images to segment fire and smoke across complex environments. The framework combines a primary YOLOv8 instance segmentation model for fire and smoke detection with a secondary object detection model pretrained on the COCO dataset to identify surrounding entities such as people, vehicles, and infrastructure. By integrating the outputs of both models, the system computes pixel-based distances between detected fire regions and nearby objects and converts these values into approximate real-world measurements using a pixel-to-meter scaling approach. This proximity information is incorporated into a risk assessment mechanism that combines fire evidence, object vulnerability, and distance-based exposure to produce a quantitative risk score and alert level. The proposed framework achieves strong performance, with precision, recall, and F1 scores exceeding 90% and [email protected] above 91%. The system generates annotated visual outputs showing fire locations, detected objects, estimated distances, and contextual risk information to support situational awareness. Implemented using open-source tools within the Google Colab environment, the framework is lightweight and suitable for deployment in industrial and resource-constrained settings.
Sep 5, 2026

Distilling Vision-Language Models for On-Device Fire Understanding

Vision-language models (VLMs) offer a promising alternative to conventional fire detection systems by reasoning about the semantic context of a scene and thus reducing false alarms, yet their large model size makes deployment on embedded fire sensors impractical. In this paper, we study how domain-specialized VLMs can be compressed for fully on-device deployment without losing the safety-critical behavior required for fire detection. We develop a teacher-student knowledge distillation framework in which large VLMs fine-tuned for fire understanding can be distilled into lightweight students. Experiments across multiple VLM families and model scales show that compact students preserve most of their teachers' fire-understanding capability. We further deploy the distilled models on our commercial Detectium fire detection sensor and jointly evaluate reasoning accuracy, latency, and memory usage. The results show that compression and deployment affect not only accuracy but also model failure modes, with Qwen2.5-0.5B providing the strongest overall deployment trade-off. Our findings provide broader guidance for deploying domain-specialized VLMs in resource-constrained, safety-critical settings.