TACTUS: A Robotic Palpation System for Spatially Heterogeneous Hardness Mapping of Woody Breast Myopathy
Organizations: Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR, USA, 72701. · Department of Food Science, University of Arkansas, Fayetteville, AR, USA, 72701. · Department of Poultry Science, University of Arkansas, Fayetteville, AR, USA, 72701.
Abstract
Woody breast (WB) myopathy is a spatially heterogeneous fibro-degenerative condition of the broiler Pectoralis major muscle. Existing mechanical reference methods rely on single-point or sequential compression measurements, limiting characterization of spatial hardness variability. This study presents TACTUS (Tactile Adaptive Conformal 3D Uniform Sensing), an automated tactile array that generates thickness-normalized, three-dimensional hardness maps at 20 anatomically distributed locations within approximately 30 s. TACTUS integrates 20 independently motorized tactuators with force-sensing resistors and encoder-driven linear actuators, alongside a LiDAR depth camera for surface profiling and adaptive compression. The system was evaluated using 100 broiler breast fillets across four WB severity classes (Normal, Mild, Moderate, Severe). TACTUS identified significant force differences among severity classes (ANOVA, p < 0.001), with the strongest differentiation in the cranial region and a significant caudal effect not detected by texture-analyzer measurements. Fillet-level TACTUS force showed moderate but significant correlation with texture-analyzer measurements (Pearson r = 0.441, p < 0.001). Semivariogram, local change entropy, and heterogeneity analyses revealed increasing and anatomically structured hardness variability with WB severity. These findings demonstrate TACTUS as an automated, operator-independent platform for spatially resolved mechanical characterization and ground-truth generation to support hyperspectral and near-infrared spectroscopy-based WB classification systems.
Figures & tables
| System/Study | Domain | Sensing Modality | Array Size | Spatial Map/Depth Sensing | Key Application | Limitation vs. TACTUS |
|---|---|---|---|---|---|---|
| GelSight [ 17 ] | Robotics | 2D vision-based gel contact | Single contact | Y/N | Surface texture and force | Dense optical tactile imaging without independent force sensing or thickness normalization. |
| BioTac [ 23 ] | Surgical robotics | Fluid pressure + vibration | Single contact | N/N | Fingertip haptics | Single point only; no spatial map |
| Parajuli et al. [ 6 ] | Food (poultry) | Manual CF probe (sequential) | Manual grid | Y/N | WB hardness mapping | Slow; manual; operator-dependent; no automation |
| Ma et al. [ 19 ] | Agriculture (fruit) | Visuo-tactile (camera + marker) | Single sensor | Within patch | Peach firmness | Single contact; no distributed array; not conformal to fillet |
| Liu et al. [ 20 ] | Medical | Flexible piezoresistive array for 2D | 8 8 | Y/N | Soft tissue palpation | No thickness normalization; no depth integration |
| Conde et al. [ 24 ] | Food quality | Impact force-deformation | Single point | N/N | Cheese firmness | Single point; not spatially resolved; no depth normalization |
| Parameter | Specification | Relevance to TACTUS |
|---|---|---|
| Model / SKU | DFRobot SEN0616 (Gravity thin-film pressure sensor) | Low-cost analog thin-film FSR |
| Sensing principle | Piezoresistive thin film; resistance decreases as applied force increases | Transduced to voltage, read by ADC |
| Measurement range | 30 g – 1.5 kg ( 0.29 – 14.7 N) | Manufacturer range; empirically calibrated to fillet compression force (Section II-E) |
| Overall dimensions | 57.5 22 mm | Compact; bonded beneath the 1 1 cm square probe tip |
| Sensor diameter & thickness | 5 mm & 0.4 mm | Ultra-low profile; mounts flush under probe tip |
| Operating voltage | 3.3 – 5 V | Powered from the Arduino 5 V rail |
| Class | n | Mean | SD | Median | 95% CI |
|---|---|---|---|---|---|
| Normal | 179 | 4.25 | 4.75 | 2.75 | [2.88, 4.61] |
| Mild | 315 | 4.40 | 4.54 | 3.30 | [3.37, 4.61] |
| Moderate | 180 | 7.18 | 5.54 | 5.35 | [5.60, 7.56] |
| Severe | 225 | 7.57 | 5.85 | 5.80 | [6.03, 8.06] |
| Class | n | Mean | SD | Median | 95% CI |
|---|---|---|---|---|---|
| Normal | 200 | 5.30 | 3.22 | 4.48 | [4.35, 5.55] |
| Mild | 413 | 5.16 | 3.43 | 4.37 | [4.44, 5.23] |
| Moderate | 308 | 6.94 | 3.65 | 7.28 | [6.72, 8.28] |
| Severe | 382 | 6.67 | 3.55 | 7.01 | [6.84, 8.34] |
| Category | n pairs a | Spearman |
|---|---|---|
| Normal | 605 | 0.060 |
| Mild | 1229 | 0.135 ∗∗∗ |
| Moderate | 1114 | 0.100 ∗∗ |
| Severe | 1503 | 0.166 ∗∗∗ |
| Category | Bins | Median | Raw entropy (bits) | Evenness (0–1) |
|---|---|---|---|---|
| Normal | 6 | 1.70 | 2.38 a | 0.92 a |
| Mild | 6 | 1.01 | 1.95 b | 0.76 b |
| Moderate | 6 | 2.61 | 2.29 ac | 0.89 ac |
| Severe | 6 | 2.71 | 2.52 c | 0.98 c |