cs.LGNov 9, 2026

RadRef: A Reference-Free Metric for Radiology Report Generation

Authors: Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin, Chirag Agarwal

Organizations: University of Virginia, Charlottesville, VA, USA

Abstract

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves 73.1%73.1\% agreement with radiologist rankings among non-tied same-radiograph report pairs, with 61.8%61.8\% pair coverage and 64.3%64.3\% tie-inclusive agreement. Its non-tied agreement is close to GREEN (73.9%73.9\%) and RadFact (72.6%72.6\%), with its strongest relative results on omissions. We further evaluate 100100 model-generated and 100100 radiologist-authored reports from 100100 MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's τb=0.295τ_b = 0.295, compared with 0.3860.386 between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with τb=0.32τ_b = 0.32 on ReXVal and 0.290.29 in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

Figures & tables

Appendix figures & tables19 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 16, 2026

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.
Sep 23, 2026

Can Jev Judge Radiology Reports? Evaluating a System One Model for Clinical Factuality

An AI-generated radiology report can resemble a physician's report while omitting an abnormality, adding an unsupported finding, or reversing its presence. Measuring these factual differences is essential for evaluating report generators. We study Jev, a System One decision model, as a simple, low-cost judge of agreement with physician-written reference reports. Our evaluator checks whether each statement is supported by the other report and combines these judgments in both directions to capture unsupported claims and omissions. A single-question configuration reaches Kendall correlations of 0.573 on RadEvalX and 0.398 on RadEvalExpert with expert error counts, outperforming an open natural language inference judge under matched decomposition and aggregation. One support question per statement retains similar expert agreement to seven while using 43-45% fewer judgment input tokens. At the documented API price, judgments cost under three cents per hundred report pairs, excluding local decomposition. In a separate controlled-error test, Jev detects false negation with an AUROC of 0.977. Local RadMatch achieves stronger agreement on clinically significant errors in both expert datasets and on total errors in the shared RadEvalExpert subset. Finding-count and error-scope analyses show that benchmark agreement reflects report size and error definitions as well as medical error detection. These results support Jev as a practical judgment component for measuring factual differences in generated radiology reports and identify where more elaborate evaluation remains valuable.
Jun 13, 2026

ReportQA: QA-Based Radiology Report Evaluation

Radiology report evaluation is essential for advancing automated report generation. Natural language generation metrics have limited clinical relevance. Clinical efficacy (CE) metrics evaluate important medical findings, but focus mainly on presence and cover only a limited set of entities. Due to heavy reliance on manual annotations, it is difficult for CE metrics to extend clinical entities or attributes. In clinical practice, radiology reports serve as a medium for information transfer. Clinicians use them to perform downstream diagnostic tasks without directly inspecting images. Based on this insight, we propose ReportQA, a clinical-related and flexible radiology report evaluation framework, supporting detailed quantitative analysis of radiology report generation systems. We first collect datasets covering multiple imaging modalities and anatomical regions. We then construct knowledge trees of clinical entities and attributes with radiologist guidance, and use large language models (LLMs) to extract structured information from raw reports. Next, we generate QA pairs from predefined templates and apply quality control through self-filtering and report-based filtering. During evaluation, the report is treated as context, and an LLM acts as a judge model to answer the QA pairs. Based on the resulting QA accuracy, we introduce QAScore metric. Compared with existing metrics, QAScore shows better alignment with radiologist judgments. Experiments on multiple state-of-the-art vision-language models reveal that current report-based inference paradigms struggle to learn fine-grained clinical representations and exhibit strong negative prior biases. In contrast, question-driven inference provides a more effective alternative. For reproducibility and extensibility, we release the knowledge trees, structured reports, and QA pairs, along with the pipeline code for QA construction and evaluation.