cs.RONov 13, 2026

AI-guided robotic in situ fabrication of curvature- and tissue-adaptive wireless bioelectronics

Authors: Hiroyuki Tetsuka, Jiaju Ma, Naomi Kumano, Minoru Hirano

Organizations: Bioinspired Systems Research-Domain, Toyota Central R&D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192, Japan

Abstract

Personalized bioelectronic devices for wound therapy require not only conformal fabrication on complex body surfaces but also functional adaptation of their electrical characteristics to individual wound geometries. Here, we present an AI-guided robotic in situ printing platform for fabricating wireless wound electrotherapy devices directly on transparent wound dressings. The system integrates a 3D vision camera, a six-degree-of-freedom robotic arm, direct-ink-writing, and geometry-aware RF design optimization. AI-based wound segmentation is used to determine wound dimensions and local surface curvature, while the reconstructed three-dimensional geometry is incorporated into the electromagnetic design of the receiving coil and interdigitated electrodes. In contrast to conventional approaches that use surface geometry only for trajectory generation, the proposed method accounts for both anatomical curvature and tissue dielectric loading to compensate for geometry-induced shifts in resonant behavior. A printable silver ink was characterized in terms of rheology, dimensional reproducibility, electrical resistance, and electromechanical stability, and was used to fabricate multilayer wireless devices directly on curved polyurethane dressings. Wireless power transfer, impedance characteristics, and electric-field delivery were evaluated experimentally and numerically. Finally, robotic in situ fabrication was demonstrated on an anthropomorphic tissue-equivalent forearm phantom, where the measured dielectric properties of the phantom were incorporated into the RF optimization, enabling resonant operation near the target frequency of 25 MHz. This work establishes a perception-to-design-to-fabrication framework for geometry-adaptive wireless bioelectronics and provides a technological foundation for future physical-AI-enabled manufacturing of personalized on-body electrotherapy devices.

Explore similar work

Mar 26, 2026

Wireless bioelectronic control architectures for biohybrid robotic systems

Wireless bioelectronic interfaces are increasingly used to control tissue-engineered biohybrid robotic systems. However, a unifying engineering framework linking device design to system-level control remains underdeveloped. Here, we propose that wireless control in biohybrid robotics can be formulated as a coupled co-design problem of integrating signal delivery, spatial selectivity, scalability, and interface stability. We analyze three representative control strategies, wireless electrical stimulation, wireless optoelectronic stimulation, and neuromuscular integration, which operates within a distinct regime with characteristic trade-offs. Across these modalities, the tissue-device interface emerges as a key constraint, governing the interplay between electromagnetic coupling, circuit performance, and biomechanical response. Based on this framework, we outline practical design principles spanning electromagnetic field distribution, circuit architecture, and actuator mechanics. We further propose a transition from open-loop stimulation to closed-loop biohybrid autonomy enabled by organoid-integrated bioelectronics and bidirectional microelectrode interfaces. This work establishes a system-level perspective on wireless bioelectronic control and provides design guidelines for developing stable, scalable, and autonomous biohybrid robotic systems.
Aug 24, 2026

Electrospun Fields: 3D Nano-Fiber Material Computation as Design Method

We present a robotic electrospinning platform and design method for depositing nanofiber membranes onto non-planar, three-dimensional conductive geometries. Conventional electrospinning relies on fixed emitters and planar grounded collectors, which restricts deposition to flat substrates: on concave geometries, field shielding prevents fibers from reaching recessed regions, and material bridges across elevated features instead. We address this with a custom end-effector integrated with a six-axis UR20 arm. The tool carries a localized stepper-driven syringe pump that maintains consistent polymer flow independent of orientation, and routes high-voltage DC (up to 25 kV) directly to a robot-mounted needle, turning the arm into a mobile emitter with full kinematic control over position, orientation, working distance, and traversal velocity. Toolpaths that continuously reorient the emitter along surface normals give access to concave topologies unreachable by fixed-axis systems. We characterize the resulting deposition behavior in two parts. A catalog of four bio-compatible polymer systems (PEO, PVA, keratin-PEO, silk-PEO) establishes the operating envelope, reporting deposition speed, jet stability, fiber size, alignment, and durability for each. A taxonomy of 3D-printed conductive scaffolds spanning geometric primitives, hybrid compositions, and square, triangular, and hexagonal lattices links collector geometry to fiber alignment, density, and cross-void bridging. We also demonstrate programmable grounding, in which selectively energized pins in an array steer deposition without changing physical geometry. Assembly instructions and toolpath-generation code are released as an open-source repository.
Mar 10, 2026

Receptogenesis in a Vascularized Robotic Embodiment

Equipping robotic systems with the capacity to generate ex novo\textit{ex novo} hardware during operation extends physical adaptability. Unlike modular systems that rely on discrete component integration pre- or post-deployment, we envision physical adaptation through continuous in-body development via hardware synthesis. Drawing inspiration from circulatory systems that redistribute mass and function in biological organisms, we utilize fluidics to restructure the material interface, a capability currently unmatched in robotics. Here, we realize this proof-of-concept hardware generation through a vascularized robotic composite designed for programmable material synthesis, demonstrated via receptogenesis - the on-demand construction of sensors. By coordinating the fluidic transport of precursors with external localized UV irradiation, we drove an in situ\textit{in situ} photopolymerization that chemically reconstructed the vasculature from the inside out. This reaction converted precursors with photolatent initiator into a solid dispersion of UV-sensitive polypyrrole in PETG, establishing a sensing modality validated by a characteristic decrease in electrical impedance. The newly synthesized sensor closed a local control loop in real time to regulate wing flapping in a moth-inspired robotic demonstrator. Our work is a proof-of-concept materials basis for ex novo\textit{ex novo} hardware generation in a vascularized composite - a step towards situated robots adapting to environmental cues.