eess.IVNov 11, 2026

Hybrid quantum learning for imbalanced blood-cell classification: domain adaptation and classifier design

Authors: Gabriele D'Angeli, Cyrill Aebischer, Eryk Schiller, Gianluca Nicchiotti, Su Fong Chien, Jérôme Extermann, Enrico Pomarico

Organizations: Department of Physics, University of Geneva, Geneva, Switzerland · Geneva School of Engineering, Architecture and Landscape (HEPIA), HES-SO University of Applied Sciences and Arts Western Switzerland, Geneva, Switzerland · School of Engineering and Architecture of Fribourg (HEIA-FR), HES-SO University of Applied Sciences and Arts Western Switzerland, Fribourg, Switzerland · Axon Logic, Multidisciplinary Research and Innovation Centre, Athens, Greece

Abstract

Limited annotated data, class imbalance, and morphological similarity make white blood cell classification challenging. We benchmark hybrid variational quantum classifier heads against an affine baseline on 821 microscopy images across seven morphological classes. Using ImageNet-initialised ResNet34 backbones and repeated stratified five-fold cross-validation, we first compare direct transfer with intermediate adaptation on MLL23, a larger peripheral blood cell microscopy dataset. To guide the head comparison, we explore different encoding strategies, variational depth, and the number of independent circuit blocks. We then compare the classifier performance using the affine head and two hybrid heads across multiple random seeds, under a shared training and evaluation protocol. For this comparison, all backbones share the same MLL23-adapted initialisation. Intermediate adaptation increases mean macro-F1 across all four affine-head fine-tuning configurations. The largest gain occurs with a frozen backbone, where macro-F1 rises from 0.6850.685 to 0.7860.786, a relative improvement of approximately 14.7%14.7\%. The shallow two-block hybrid head achieves a mean pooled out-of-fold macro-F1 of 0.865±0.0100.865 \pm 0.010, compared with 0.879±0.0080.879 \pm 0.008 for the affine head. The corresponding balanced accuracies are 0.886±0.0080.886 \pm 0.008 and 0.889±0.0100.889 \pm 0.010, respectively. In the architectural exploration, the two-block hybrid head achieves the highest macro-F1 and balanced accuracy among the evaluated hybrid configurations, while the effect of encoding varies across the considered metrics. Our results help guide the design and evaluation of hybrid classifier heads for imbalanced microscopy by linking architectural choices to overall performance and class-specific precision-recall trade-offs.

Figures & tables

Appendix figures & tables8 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. Enhancing Blood Cells Classification using Hybrid Quantum Neural Networks

    May 22, 2026Guilherme Cruz, Nouhaila Innan, Alberto Marchisio +2Hybrid Quantum-Classical MLMedical Image Classification

  2. Synergizing Deep Learning and Biological Heuristics for Extreme Long-Tail White Blood Cell Classification

    Mar 17, 2026Duc T. Nguyen, Hoang-Long Nguyen, Huy-Hieu PhamWhite Blood Cell ClassificationMedical Image Classification

  3. Ensemble of Small Classifiers For Imbalanced White Blood Cell Classification

    Mar 21, 2026Siddharth Srivastava, Adam Smith, Scott Brooks +2White Blood Cell ClassificationMedical Image Classification