A prescription medicine in the United States comes with labeling written for prescribers, and many medicines also carry a text written for patients: a Medication Guide or a patient package insert. The two texts describe the same medicine for two readers, yet public resources rarely hold them side by side. I present PlainPairs, an open corpus built from the openFDA drug label files. Version 0.1.0 holds 35,177 prescription labels that carry a patient text, 21,416 distinct patient texts, 250,829 patient-text segments matched to prescriber sections through their regulatory headings, reading-level measures on both sides, and rule-based counts of plain-language wording. A second source, the National Cancer Institute's cancer information summaries, adds 756 summaries in health-professional and patient versions, in English and Spanish. Measured on the structure of the label, the median Medication Guide reads at grade 8.7 by Flesch-Kincaid and at grade 11.1 by SMOG. The same guides measured on the flattened text that the bulk files serve read about two grades higher, a difference that comes from lost list and heading boundaries. Patient texts address the reader in 41 of every 100 sentences, against 0.2 in prescriber sections. A blind hand check of 100 pairs supports the heading-based alignment for seven of ten heading types. The corpus, its code and its documents are public, and the release keeps texts that show a company copyright mark out of the text tables.
Figures & tables
Resource
Expert side and plain side
Size
Language
PLABA ( Attal et al., 2023 )
PubMed abstracts; adaptations written for the corpus
750 abstracts, 7,643 sentence pairs
English
Med-EASi ( Basu et al., 2023 )
Short expert texts; simple versions with edit annotations
1,979 pairs
English
Cochrane summaries ( Devaraj et al., 2021 )
Review abstracts; the reviews’ plain-language summaries
about 4,459 pairs
English
CELLS ( Guo et al., 2024 )
Journal abstracts; author lay summaries
62,886 pairs
English
eLife and PLOS ( Goldsack et al., 2022 )
Journal articles; lay summaries
about 32,000 pairs
English
MSD Manual ( Cao et al., 2020 )
Professional and consumer versions of one manual
675 aligned test pairs
English
Table 1: Resources that pair expert and lay medical text, as their papers or data cards describe them.
Source
Used for
Date
openFDA drug label export
every label and its text
13 Nov 2026
openFDA NDC directory export
the flag listed_in_ndc_directory
13 Nov 2026
DailyMed full release, human prescription labels
text structure of current labels
13 Nov 2026
DailyMed list of served labels
the flag served_by_dailymed
15 Nov 2026
National Cancer Institute summary pages
the nci configuration
15 Nov 2026
Table 2: Sources of version 0.1.0 and the dates they were read.
Labels
Labels in the export
264,748
In a prescription format, with a Medication Guide or a patient package insert
35,177
newer prescription format / older format
25,796 / 9,381
with a Medication Guide / with a patient package insert / with both
22,872 / 12,519 / 214
with Instructions for Use
2,059
with the source’s product block ( openfda )
15,022
Table 3: From the export of 13 November 2026 to the corpus.
Figure 1: The build pipeline of version 0.1.0.
Configuration
Table
Layer
Rows
MB
current
labels
record
19,778
20.2
patient_texts
record
12,857
2.5
section_pairs
record
143,885
5.1
codes
record
221,072
2.9
text_prescriber
text
260,290
242.6
text_patient
text
33,003
41.4
Table 4: Files of version 0.1.0.
Patient segment, under the heading on how to take the medicine
“Take [medicine] exactly as your healthcare provider tells you. Take it one time each day, with or without food. Do not change your dose or stop taking [medicine] without talking to your healthcare provider.”
Prescriber section, Dosage and Administration
“The recommended dosage is 10 mg orally once daily, with or without food. The dosage may be increased to 20 mg once daily after 4 weeks, based on clinical response and tolerability.”
We introduce PlainMedScale, a topic-aligned medical corpus spanning four levels of comprehensibility in German and English, drawn from MSD (professional and consumer), Gesund.Bund, Apotheken Umschau Einfache Sprache, and the NHS. The four tiers correspond to distinct communicative functions --- reference, explanation, decision support, and access --- and move beyond the binary expert--lay contrast of prior corpora. In two pilot studies enabled by the alignments, we show that many readability metrics established on two registers fail to generalize across the full gradient, and that a SOTA open-weight LLM prompted for Plain Language still partially preserves the difficulty of its input. Code (https://github.com/GS-Uni-Heidelberg/PlainMedScale) and data (https://doi.org/10.5281/zenodo.21728290) are made available.
Bruno Brocai, Ilaria Papagno, Mayumi Ohta
Heidelberg University German Linguistics · Heidelberg University Translation Studies · Heidelberg University SFB 1671
Every medication comes with two types of medical facts: indications, which describe what conditions the drug treats (benefits), and contraindications, which describe who must avoid it to prevent serious harm (safety limits). Although contraindications are critical for patient safety and FDA regulations require listing them as rigorously as indications, we find that contraindications are far less documented than indications in general prose. In this paper, we measure how often these texts contain both facts across 574 drugs from PrimeKG by comparing a drug's indications against its own contraindications. Across Wikipedia articles and PubMed abstracts, we find that reference prose names a drug's benefits about twice as often as its safety limits (within-drug odds ratio 2.19). We call this documentation gap LABEL (Literature Asymmetry between Efficacy and Limits). Language models mirror this gap. As we scale Qwen2.5 from 0.5B to 14B, accuracy on indications rises by 18.3 points, whereas accuracy on contraindications remains flat near random guessing. However, when we provide models with a retrieved passage that states the answer, they use safety facts just as effectively as benefits. Furthermore, routing safety questions to official FDA labels boosts accuracy by 15.8 points whenever the label states the fact. Overall, our findings show that models fail on medication safety not because they cannot reason about risk, but because free-text corpora lack safety facts. Clinical AI systems should therefore route medication-safety questions to official regulatory labels and structured databases rather than relying on general public records. Code and data are available at https://github.com/SMRayeed/LABEL.
Medical Vision-Language Models (Med-VLMs) achieve strong expert-level performance, yet their ability to generate patient-accessible descriptions remains underexplored. With the 21st Century Cures Act now mandating immediate patient access to diagnostic imaging results, evaluating whether Med-VLMs can bridge this Expert-Lay Gap is both urgent and clinically consequential for patient education and shared decision-making. To this end, we introduce MedLayXPlain, the first large-scale multimodal benchmark and evaluation framework for Medical Lay Language Generation (MLLG). MedLayXPlain-122K provides 122,789 region-grounded samples across 8 imaging modalities from 12 publicly available source datasets, each comprising a medical image with paired expert and lay captions anchored in a three-level Unified Medical Language System (UMLS) ontology hierarchy spanning 7 semantic groups, 43 semantic types, and 2,411 medical concepts. Lay captions are constructed via Hierarchical Ontology-Verified Refinement (HOVER), a three-step pipeline combining patient-centric vocabulary mapping, LLM-based constrained rewriting, and cross-model visual verification to enforce semantic equivalence while preventing hallucination. We further introduce MedLayEval, a lightweight 3B evaluator distilled from a 27B verifier that scores expert-lay alignment across five clinically grounded attributes, addressing the poor correlation between standard NLG metrics and clinical judgment. Benchmarking 33 VLMs on MedLayXPlain-122K reveals a systematic Expert-Lay Gap: medical VLMs achieve strong expert captioning but suffer significant lay-register degradation, while general-purpose VLMs produce more accessible language yet lack clinical precision, confirming that neither current paradigm adequately serves patient-facing communication.
Han Jang, Junhyeok Lee, Songsoo Kim +4
1Seoul National University · 2Seoul National University Hospital · 3Seoul National University College of Medicine +1