cs.LGNov 16, 2026

TIBECG: Temporal Information Bottleneck for Lead-Specific Demographic Privacy in ECG Waveform Release

Authors: Tsai-Min Chen, Jun Seita

Organizations: Research Center for Information Technology Innovation, Academia Sinica, Taipei, Taiwan · RIKEN Center for Interdisciplinary Theoretical and Mathematical Sciences

Abstract

Transmitting an electrocardiogram (ECG) waveform can expose demographic information beyond an intended diagnostic task. We evaluate TIBECG, an architectural temporal information bottleneck, on individual leads extracted from hospital twelve-lead recordings. A 2,302,337-parameter processor varies its latent length while retaining the same nine-score consistency objective, without age or sex labels in protector fitting. Across 6,386 recordings, ten folds, 12 leads and 21 lengths, retrospective selections retained at least 95% of each lead's clean macro-F1. Their weaker age/sex interval gain exceeded the best eligible conventional transformation on all leads, by a median 22.08 percentage points. The implemented sampling-rate comparison shows that direct downsampling usually suppresses demographic inference more strongly but at a larger loss of diagnostic utility, whereas TIBECG favors utility preservation. Selection stability also varies by lead. Lower latent Kullback-Leibler (KL) divergence does not reliably rank residual sex leakage at a fixed length. These findings support lead-specific evaluation of waveform processing, not validated consumer deployment or expert-readable reconstruction. When the waveform-input diagnostic classifier is hosted as part of a proprietary cloud service rather than deployed on the device, waveform transmission is required to obtain its scores.

Explore similar work

Oct 9, 2026

ECGGuard: Deep Watermarking of Electrocardiogram Signals With Error-Correcting Codes

Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, leaving patient metadata vulnerable to loss. Digital watermarking can embed this metadata in the signal, but conventional methods fail under time shifts, and high waveform similarity does not guarantee the same downstream diagnosis. We present \rev{ECGGuard}, a deep watermarking framework for single-lead ECG. A fully convolutional generator embeds the payload without signal quantization, a detector decodes the message frame by frame and checks for watermark presence, and during training a frozen arrhythmia classifier penalizes changes that would alter its predictions. Because high bit accuracy does not ensure whole-message recovery, the payload is protected by extended Hamming codes, \rev{a validation-selected channel ordering}, and soft-decision decoding. On the MIT-BIH Arrhythmia Database, \rev{averaged over three training runs, ECGGuard} keeps bit accuracy above \rev{98%} under time shifts of 10 to 50 samples, where transform-domain baselines drop to chance. The coded 16-bit payload is recovered exactly in \rev{99.95%} of clean segments\rev{, in over 96%} under time shifts, 10% sample deletion, or 10% packet loss\rev{, and in 99.1% for unseen subjects}. \rev{For the guiding classifier, the diagnostic loss limits the drop in ventricular-beat sensitivity to 1.6 percentage points on the test records (35.0 without it) and to 12.2 points for unseen subjects (67.0 without it); the drop grows to 10.3 points for independently trained classifiers, and the protection does not transfer to an external database.} \rev{ECGGuard} has 0.56 million parameters and needs about \rev{19}~ms per segment on a desktop CPU.
Jul 7, 2026

REAN: Reconstruction-aware ECG Anonymization Based on Privacy--Utility Orthogonality

A shared electrocardiogram (ECG) is itself a biometric fingerprint that can re-identify a patient and reveal personal information. Recent ECG anonymizers transform the signal before sharing to reduce privacy leakage. However, existing methods still face a privacy--utility trade-off, in which preserving privacy often compromises utility while preserving utility reveals personal information. We propose REAN (REconstruction-aware ECG ANonymizer), a raw ECG signal anonymizer, to address this privacy--utility trade-off. REAN reconstructs the signal using a 1-D U-Net trained with losses from frozen privacy and utility classifiers to reduce privacy leakage while preserving utility. The privacy and utility gradients are near-orthogonal (≈\approx93.8∘^\circ), so reducing privacy leakage leaves utility almost unchanged. On four public PhysioNet databases, REAN achieves the strongest privacy--utility balance among raw ECG signal baselines. It drives re-identification to chance (0.96→\to0.00), keeps arrhythmia macro-AUROC at the clean level (Clean 0.9982 vs.\ REAN 0.9991), and maintains re-identification protection under unseen privacy-classifier architectures.
Mar 18, 2026

Pathology-Aware Multi-View Contrastive Learning for Patient-Independent ECG Reconstruction

Reconstructing a 12-lead electrocardiogram (ECG) from a reduced lead set is an ill-posed inverse problem due to anatomical variability. Standard deep learning methods often ignore underlying cardiac pathology losing vital morphology in precordial leads. We propose Pathology-Aware Multi-View Contrastive Learning, a framework that regularizes the latent space through a pathological manifold. Our architecture integrates high-fidelity time-domain waveforms with pathology-aware embeddings learned via supervised contrastive alignment. By maximizing mutual information between latent representations and clinical labels, the framework learns to filter anatomical "nuisance" variables. On the PTB-XL dataset, our method achieves approx. 76% reduction in RMSE compared to state-of-the-art model in patient-independent setting. Cross-dataset evaluation on the PTB Diagnostic Database confirms superior generalization, bridging the gap between hardware portability and diagnostic-grade reconstruction.