cs.CLNov 17, 2026

Compact and Decodable Electrocardiogram Text for Large Language Models

Authors: Elif Dorukbaşı, İlker Türker

Organizations: Department of Computer Engineering Faculty of Computer and Information Sciences Karabük University, Karabük, Türkiye

Abstract

When a twelve-lead electrocardiogram is written as text for a large language model, the number of tokens has to be balanced against the information lost through compression. This paper presents a deterministic encoding that writes eight independent leads as amplitude letters and exact time gaps and recovers the remaining four limb leads algebraically. The key points are selected with a cardiac-cycle-dependent tolerance, the amplitudes are parameterized by a 26-letter logarithmic codebook learned from a training set, and a 10-step tolerance schedule keeps all records within a fixed token budget. The encoding was applied to 21,388 records from the public PTB-XL database and evaluated using an exact decode-and-re-encode round trip, waveform reconstruction error, and a paired comparison of convolutional classifiers trained with 5 different seeds on signals from the original and decoded databases. All records were contained in 4,080 tokens (average: 2,866 tokens, 64.3% fewer than a per-sample transcription), and all stored lead strings were exactly reproduced. The average correlation between the decoded and reference signals was 0.982. The macro-averaged area under the receiver operating characteristic curve was 0.9167 for the reference signals and 0.9157 for the decoded signals (paired difference -0.0010; 95% patient-level bootstrap interval, -0.0028 to 0.0007), within the pre-specified non-inferiority margin of -0.010; this is not a confirmatory result, because the test fold had been used during encoder development. The diagnostic content of a compact text can therefore be preserved, while the language model's ability to read the text is yet another matter.

Figures & tables

Explore similar work

Jan 5, 2026

ELF: A Family of Encoder-Free ECG-Language Models

ECG-Language Models (ELMs) extend recent advances in Multimodal Large Language Models (MLLMs) to automated ECG interpretation. However, most existing ELMs inherit Vision-Language Model (VLM) design choices and rely on pretrained ECG encoders, introducing substantial architectural and training complexity. Inspired by encoder-free VLMs, we introduce ELF, a family of three encoder-free ELMs that remain competitive with, and often outperform, prior state-of-the-art ELMs across two datasets despite substantially simpler architectures and training pipelines. All code and data are available at github.com/ELM-Research/ECG-Language-Models.
Nov 13, 2026

LEAP-LLM: Preserving lead-time structure for question-conditioned ECG interpretation

The electrocardiogram (ECG) records cardiac electrical activity across multiple leads and is used for detecting cardiac abnormalities. Recent ECG-language models enable large language models (LLMs) to interpret cardiac signals and answer clinically relevant questions. However, existing ECG-language models typically encode the ECG independently of the clinical question, forcing the ECG representation to retain broad and potentially irrelevant signal information. Moreover, these models often aggregate information across leads which can obscure lead-specific details needed for a particular question. To tackle these limitations, we introduce LEAP-LLM, an ECG-LLM architecture for Lead-aware ECG Alignment with Prompt conditioning. LEAP-LLM uses the clinical question to guide ECG feature extraction while preserving explicit lead and temporal structure. Task-trained instruction representations distill information from the question and guide two complementary branches. The Lead branch captures question-relevant temporal patterns within each ECG lead, while the Temporal branch summarizes relevant information across leads at each temporal position. Together, they provide the LLM with compact, question-relevant ECG information while preserving lead and temporal structure. LEAP-LLM reduces modality-token count by 89.0% and prefill FLOPs by 7.2x on average relative to other ECG-LLMs baselines. Across four ECG benchmarks, LEAP-LLM achieves better performance, including a 3.4-percentage-point improvement in G12EC over the strongest prior ECG-specific method. We further show that the model adaptively emphasizes the clinically relevant anatomical lead groups for different cardiac abnormalities, with lead importance patterns consistent with established diagnostic knowledge, providing interpretable evidence that the predictions are supported by clinically meaningful ECG structure.
Aug 31, 2026

Beat-Synchronous Tokenization for ECG Transformers

Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split heartbeat structures across token boundaries. We study beat-synchronous tokenization as a physiologically grounded alternative, comparing fixed patches with three beat-aligned strategies: resampled beats, adaptive pooled beats, and resampled beats augmented with R--R interval information. Experiments span two settings: 10-second 12-lead diagnostic classification on PTB-XL after MIMIC-IV-ECG masked pretraining, and 60-second single-lead rhythm classification on Icentia11k after patient-level contrastive pretraining. On PTB-XL, resampled beat tokens achieve the highest mean macro Area Under the ROC Curve (AUROC; 0.8945) and nearly match the best fixed-patch macro Area Under the Precision-Recall Curve (AUPRC; 0.7414), reducing average sequence length from 100 to 11.2 tokens. On Icentia11k, beat-synchronous tokenizers obtain comparable AUPRC to fixed patching with better stability across runs. These results suggest morphology-preserving beat tokenization is a compact, competitive alternative to fixed temporal patching.