Absolute 3D human pose estimation (HPE) aims to recover both a person's body pose and their global position in 3D space. Privacy-preserving millimeter-wave (mmWave) radar provides distance and direction measurement capabilities, but its sparse point clouds make HPE under-constrained. Low-resolution thermal imaging can provide complementary observations of body direction and structure. However, our evaluation shows that a strong feature-level fusion baseline loses much of its localization and HPE advantage when generalizing to unseen subjects, with radial localization becoming less accurate than a radar-only baseline. Motivated by this finding, we introduce mmTherm, a lightweight framework that explicitly incorporates the complementary geometric properties of thermal imaging and mmWave radar. It combines body structure and joint directions estimated from thermal images with range information from radar to localize the body and reconstruct its 3D pose. Experiments on OctoNet show that mmTherm reduces cross-user absolute joint error by 33% and root localization error by 38% relative to the strongest corresponding baselines, while requiring substantially fewer parameters and less computation at inference.
Figures & tables
Figure 1: Complementary geometry for absolute 3D HPE. (a) Radar provides range information through sparse and noisy point clouds. (b) Thermal images provide coarse body structure and direction; orange planes illustrate depth ambiguity. (c) mmTherm explicitly combines thermal direction and radar range evidence for pose reconstruction.
Figure 2: Overview of mmTherm. Stage 1 combines thermal geometry with radar observations to localize the root. Using the predicted root and body box, Stage 2 estimates joint directions from thermal images and joint ranges through thermal-guided radar attention. These estimates form an initial 3D pose, which is then refined by a spatiotemporal network.
Figure 3: Qualitative HPE results on unseen users. Each column uses the same frame across methods. Dashed skeletons are ground-truth poses. Values indicate absolute MPJPE in mm. The best result in each column is bold.
In-domain
Cross-user
Method
ABS
Root
RA
ABS
Root
RA
mmDiff [ 8 ]
–
–
126.5
–
–
135.6
WiCompass [ 16 ]
173.1
149.6
103.2
265.5
249.3
148.5
Wave2Body [ 15 ]
129.4
96.8
91.6
187.1
153.9
129.3
MIRaSeg-Pose [ 22 ]
80.4
62.7
63.7
178.1
156.4
111.1
mmTherm (ours)
80.2
57.3
66.2
118.7
95.1
98.8
Table 1: 3D HPE errors on OctoNet (mm, lower is better). ABS: absolute MPJPE; Root: root position error; RA: root-aligned MPJPE.
Figure 4: Robustness evaluation. (a) The top 20% of recordings by the clutter ranking; black ticks show full-test errors. (b) Absolute MPJPE after radar point removal.
Figure 5: Missing-return diagnostic . (a) Root-aligned error by radar point count within 0.2 m of reference joints. (b) Root-aligned error by body part. Error bars: 95% recording-bootstrap intervals.
In-domain
Cross-user
Method
Lat.
Range
3D
Lat.
Range
3D
Wave2Body
75.6
47.2
96.1
131.7
60.6
154.0
MIRaSeg-Pose
32.9
47.3
62.8
78.5
123.7
156.2
mmTherm
36.4
36.9
57.0
67.0
55.7
95.0
Table 2: Final root localization errors across methods on 20k sampled test frames (mm, lower is better).
Stage 1 variant
Lateral
Range
3D
Radar only
123.0
59.9
145.1
Feature fusion
84.2
56.9
110.7
Full fusion
71.3
56.4
99.9
Table 3: Comparison of Stage 1 root fusion strategies on unseen users (mm, lower is better).
In-domain
Cross-user
Stage 2 variant
ABS
Root
RA
ABS
Root
RA
Full model
80.2
57.3
66.2
118.7
95.1
98.8
w/o S2 radar points
100.3
74.1
87.1
143.6
104.1
126.3
w/o temperatures
99.2
64.6
84.6
140.4
107.8
116.6
w/o geometric init.
83.1
62.0
65.5
127.8
98.2
101.0
Table 4: Stage 2 ablations (mm, lower is better). Removing temperatures preserves the thermal box and calibrated rays.
School of Computer Science, Peking University · University of Pittsburgh · Key Laboratory of High Confidence Software Technologies, Ministry of Education (PKU)
CCS Graduate School of Mobility, Korea Advanced Institute of Science and Technology, Daejeon 34051, South Korea · Robotics Program, Korea Advanced Institute of Science and Technology, Daejeon 34141, South Korea