cs.CVNov 18, 2026

Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET

Authors: Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg, Bo Zhou

Organizations: Department of Radiology, Northwestern University, Chicago, IL 60611 USA · Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL 60208 USA · Division of Cardiology, Department of Medicine, Northwestern University, Chicago, IL 60611 USA

Abstract

Positron emission tomography (PET) provides quantitative information on myocardial perfusion. In dynamic PET, tracer kinetics are tracked through a series of reconstructed time frames. Reliable attenuation correction is essential for accurate measurements. Clinical attenuation maps (μμ-maps) are typically derived from computed tomography (CT), which adds radiation exposure and may introduce PET-CT misregistration due to respiratory and cardiac motion. Moreover, supervised CT-free methods rely on paired non-attenuation-corrected (NAC) PET and CT data, which are scarce, whereas large-scale unpaired CT data are more readily available. To address these challenges, we propose Large-scale Unpaired CT-Informed Diffusion (LUCID), a framework that transfers anatomical priors learned from 10,000 chest CT volumes in the public CT-RATE dataset to μμ-map synthesis for dynamic cardiac 82^{82}Rb PET. First, a convolutional neural network (CNN) predicts an initial μμ-map from each NAC PET frame. Second, the CT-pretrained diffusion backbone refines a low-noise perturbation of the CNN prediction through a single denoising step, conditioned on the corresponding NAC PET frame via ControlNet. Finally, frame-wise predictions are averaged voxel-wise to obtain the final μμ-map. We further introduce the voxel-wise temporal standard deviation (TSD) to quantify inter-frame variability without requiring a reference μμ-map. We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency. Ablation studies showed that refinement with a diffusion backbone pretrained on in-house CT data from the training patients was less accurate than the CNN prediction alone, highlighting the importance of large-scale CT pretraining.

Figures & tables

Explore similar work

Mar 8, 2026

DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising

Rb-82 dynamic cardiac PET imaging is widely used for the clinical diagnosis of coronary artery disease (CAD), but its short half-life results in high noise levels that degrade dynamic frame quality and parametric imaging. The lack of paired clean-noisy training data, rapid tracer kinetics, and frame-dependent noise variations further limit the effectiveness of existing deep learning denoising methods. We propose DECADE (A Temporally-Consistent Unsupervised Diffusion model for Enhanced Rb-82 CArdiac PET DEnoising), an unsupervised diffusion framework that generalizes across early- to late-phase dynamic frames. DECADE incorporates temporal consistency during both training and iterative sampling, using noisy frames as guidance to preserve quantitative accuracy. The method was trained and evaluated on datasets acquired from Siemens Vision 450 and Siemens Biograph Vision Quadra scanners. On the Vision 450 dataset, DECADE consistently produced high-quality dynamic and parametric images with reduced noise while preserving myocardial blood flow (MBF) and myocardial flow reserve (MFR). On the Quadra dataset, using 15%-count images as input and full-count images as reference, DECADE outperformed UNet-based and other diffusion models in image quality and K1/MBF quantification. The proposed framework enables effective unsupervised denoising of Rb-82 dynamic cardiac PET without paired training data, supporting clearer visualization while maintaining quantitative integrity.
Aug 22, 2026

Region-Weighted Losses and Model Fusion for Cross-Modal PET Attenuation Correction

We describe our approach to the Big Cross-Modal Attenuation Correction (BIC-MAC) challenge, which asks for a pseudo-CT in Hounsfield Units to be synthesized from Non-Attenuation-Corrected PET (NAC-PET), DIXON MRI and a topogram, and scores both the pseudo-CT and the Attenuation-Corrected PET (AC-PET) reconstructed from it. Three ideas carried our improvements over the organizers' 3D U-Net baseline. The loss matters more than the architecture: we compute the L1L_1 error in the Carney attenuation-coefficient (μμ) space that the CT metric itself uses, weighted by anatomical region. Only once that loss was in place did the unregistered DIXON MRI work as extra input channels. A fixed convex combination of two independently trained models then beat both of its members on three of the four metrics and ranks first overall on the public validation leaderboard.
Jul 1, 2026

AnF-DiffPET: Anatomy- and Frequency-Guided Diffusion for PET/CT Denoising

Positron emission tomography (PET) provides essential functional information for disease assessment, however reducing injected activity or acquisition time produces low-dose (LD) PET with stronger count dependent noise and less reliable uptake quantification. Diffusion models offer a promising solution for PET denoising by progressively recovering high-dose (HD) PET images from LD inputs. However, LD-to-HD PET denoising is still challenging due to insufficient anatomical guidance, unstable multi-scale feature propagation, and uncertain frequency domain uptake recovery. We propose AnF-DiffPET, an anatomy- and frequency-guided diffusion framework for computed tomography (CT) conditioned LD PET denoising. The framework integrates Anatomical-Frequency Guidance (AFG), Multi-Scale Cross-Transformer Reconstruction (MSCTR), and Frequency-Contrastive Hard Mining (FCHM) to enhance anatomy aware feature modulation and frequency domain consistency during denoising. Experimental results across four PET/CT datasets show that the proposed method improves image fidelity, anatomical consistency, and quantitative fidelity over representative CNN-based, GAN-based, transformer-based, and diffusion-based methods. The code and trained models will be publicly released upon acceptance.