cs.CVNov 18, 2026

SCOUT: Risk-Guided Foundation-Model Escalation for Robust Tissue Detection in Whole-Slide Images

Authors: Cristian Tommasino, Antonio M. Rinaldi

Organizations: Department of Electrical Engineering and Information Technology (DIETI), University of Naples Federico II, Naples, Italy

Abstract

Reliable tissue detection is essential for whole-slide image analysis, yet high average segmentation accuracy can conceal failures involving pale tissue, small fragments, and heterogeneous staining. Pathology foundation models offer transferable representations, but exhaustive inference is computationally demanding and may introduce false-positive tissue predictions. We propose SCOUT (Selective Correction of Uncertain Tissue), a risk-guided cascade that selectively refines an initial thumbnail-based tissue mask. A lightweight audit network estimates the spatial distribution of segmentation errors and prioritizes candidate regions for processing by a frozen pathology foundation model. An asymmetric consensus rule integrates the resulting predictions with the initial mask to recover missed tissue while limiting false positives. A calibrated slide-level review score additionally controls the marginal rate of unflagged case-group failures under the calibration assumptions. Evaluation on a public multi-source, multi-stain benchmark shows that SCOUT reduces the proportion of case groups requiring mask correction from 38.1% for the best released detector to 18.6%, with particularly pronounced improvements in immunohistochemistry. Source-held-out experiments demonstrate better generalization than a segmentation network trained on the same annotations, while selective inference achieves an observed failure rate no higher than processing all candidate regions. Downstream, lymph-node classification with SCOUT masks is non-inferior to that obtained with two of the three released detectors evaluated. A variant built on an openly licensed foundation model is publicly released as an installable Python package with trained weights. These results support risk-guided foundation-model inference as an effective approach to tissue detection across heterogeneous histopathology data.

Figures & tables

Explore similar work

Sep 1, 2026

FTU-Seek: Foundation Model-Guided Hard-Negative Learning for Sparse Functional Tissue Unit Segmentation

Functional tissue units (FTUs), including tertiary lymphoid structures (TLSs), blood vessels, and glands, encode localized immune, vascular, and epithelial organization in histopathology. Accurate quantification of these structures is important for studying tissue architecture and disease-associated tissue organization. However, FTUs are frequently sparse, heterogeneous, and surrounded by large amounts of morphologically similar background tissue, making automated segmentation in whole-slide images (WSIs) challenging. We therefore developed FTU-Seek, a pathology foundation model-guided framework that treats morphology-aware negative-patch selection as a key component of sparse FTU segmentation. FTU-Seek uses frozen multi-depth features from the UNI pathology foundation model to train a patch-level classifier that distinguishes FTU-containing from FTU-absent tissue. Target-absent patches are subsequently ranked according to their predicted target-containing probabilities, and the highest-scoring hard negatives are selected through a static TopKK strategy to construct compact segmentation training sets. The framework was evaluated using five-fold cross-validation and internal test cohorts across TLS, blood-vessel, and gland segmentation tasks, with an additional independent 30-WSI held-out cohort for TLS. Positive-only, all-tissue, random-negative, and matched random TopKK sampling strategies served as comparators. Segmentation-derived phenotypes were further explored in external TCGA cohorts.
Sep 30, 2026

The Effect of Tissue Detection on False Positives of Diffusion-Based Artifact Detection in Histopathology

One-class artifact detectors for whole-slide images learn normal tissue from a clean training pool and flag departures from it. The pool is built by a preprocessing pipeline whose tissue-detection step is usually treated as neutral. We tested whether it is. On 16 annotated slides from The Cancer Genome Atlas, we rebuilt the clean pool of a diffusion-based detector with different tissue detection methods and compared the resulting models in a four-fold cross-validation. Per-slide saturation-Otsu detection excluded normal tissue, chiefly tissue with large clear spaces such as adipose tissue and alveolar parenchyma, and on slides with thick marker ink kept the ink while excluding ordinary tissue. Replacing it with entropy-based detection reduced the false-positive fraction on held-out clean slides from 0.102 to 0.016, in every fold and with a second training seed, without loss of sensitivity; the gain came from the composition of the pool, not its size. Across three tissue detection methods, false positives followed the fraction of such clear-space tissue in the pool, a statistic that needs no labels or training (0.103, 0.016 and 0.009). The effect did not carry over at the same size to a nearest-neighbour detector on foundation-model features. On an external cohort, the curated pool lowered clean-control false positives by about 20%, far less than on the development slides, and the remaining cross-center loss was not explained by stain differences. For one-class quality control, tissue detection decides what the model learns as normal and should be chosen and reported accordingly.
Apr 28, 2026

Validation of Whole-Slide Foundation Models for Image Retrieval in TCGA Data

Foundation models are reshaping computational histopathology, yet their value for whole-slide image retrieval relative to strong patch-based and supervised aggregation baselines remains unclear. We benchmarked ten pipelines on 9,387 diagnostic slides spanning 17 organs and 60 diagnoses from The Cancer Genome Atlas (TCGA) using patient-level leave-one-patient-out evaluation. Methods included four pre-trained slide foundation models, a supervised attention-based multiple instance learning (ABMIL) aggregator on patch embeddings, and patch-level retrieval across five sampling densities. Performance varied more across organs and diagnoses than across architectures. Although the slide foundation model TITAN achieved the strongest overall results, its advantage was modest; ABMIL and patch-based methods reached comparable Top-1 and Top-3 accuracy, with no model consistently dominant. Morphologically distinctive entities approached ceiling performance, while rare, heterogeneous, and closely related subtypes remained challenging. Misclassifications aligned with organs exhibiting known inter-observer variability, suggesting an intrinsic ceiling for morphology-only retrieval. Performance was driven primarily by patch-level feature representations, with limited benefit from slide-level aggregation, indicating aggregation may be unnecessary in many settings. These findings argue against a universally optimal architecture and instead support organ-resolved benchmarking, diagnosis-aware or ensemble strategies, stronger feature representations, and multimodal retrieval frameworks. Notably, even the best model achieved only ≈68%±21%\approx 68\% \pm 21\% retrieval accuracy on TCGA, and some subtypes showed 0%0\% accuracy across all methods, highlighting fundamental limitations of morphology-based representations and the need for substantial progress before reliable clinical deployment.