cs.AINov 19, 2026

COVERAGE-TRACE: Source-Side Counterfactual Tracing for Detecting Omissions in LLM Summaries

Authors: Ali Karkehabadi, Jamshid Hassanpour, Rafael E. Banchs

Organizations: University of California, Davis · Intapp · Georgia Institute of Technology · San Jose State University

Abstract

Omissions are difficult to verify because missing information leaves no output span to inspect: a summary may be factually supported while still excluding a decision, qualification, quantity, or condition needed to preserve the source's meaning. We introduce COVERAGE-TRACE, a source-side counterfactual framework that evaluates omission as dependence on a designated atomic source fact. It replaces only the target fact with type-matched alternatives, holds the candidate summary fixed, and measures the resulting change in its teacher-forced, length-normalized likelihood. A summary covering the target should respond more strongly than one omitting it, while aggregation across multiple counterfactuals reduces sensitivity to replacement choice. We evaluate COVERAGE-TRACE on 80 matched covered--omitted QMSum pairs spanning several fact types and four open-weight models. Multi-CF achieves 0.764--0.825 AUROC, compared with 0.640 for the strongest evaluated text-only baseline. On Falcon-7B, targeted interventions achieve 0.779 AUROC, whereas shuffling counterfactual assignments reduces performance to 0.533; target deletion is effective while unrelated deletion is not. However, adjustment for meaning-preserving paraphrases reduces AUROC to 0.591--0.624. COVERAGE-TRACE therefore provides a practical, complementary signal of target-specific source--summary dependence, but not a wording-invariant semantic coverage probability. These results establish source-side intervention as a promising approach to omission detection while identifying semantic invariance as the central remaining challenge.

Figures & tables

Explore similar work

Nov 14, 2026

OmitEHR: Scalable Omission Detection in LLM-Generated Clinical Summaries

Health systems increasingly rely on large language models (LLMs) to draft summaries of patient medical records, yet evaluations now find omissions, the absence of clinically important information, to be the most common failure mode. Detecting omissions in an LLM-generated summary requires knowing which facts in the record are salient, a signal that existing methods hand-specify, ignore, or recompute at inference with costly LLM judges. We present OmitEHR, a reference-free omission detector that learns clinical salience from historical clinician-written summaries predating widespread LLM use. OmitEHR learns to predict which source-note sentences clinicians include in their summaries, then surfaces high-salience sentences not covered by an LLM-generated summary as candidate omissions. We apply OmitEHR to brief hospital course (BHC) summarization using 5,000 admissions from a large academic medical center. On held-out admissions, OmitEHR outperformed all evaluated baselines at predicting salient source sentences, including a prompted LLM judge. The full omission detection pipeline took 17.7 to 19.5 seconds and cost $0.03 to $0.13 per summary depending on the base model, 1.6 to 1.7 times faster and 5.6 to 6.7 times cheaper than scoring every source sentence with an LLM judge. In a blinded review of 25 admissions, two board-certified clinicians confirmed a mean of 5.6 clinically meaningful omissions per summary surfaced by OmitEHR, compared with 3.3 for a full LLM pipeline, counting candidates confirmed by at least one clinician. The efficiency and validity of OmitEHR make it a practical tool for health systems to flag omissions before a summary reaches the clinician.
Jul 24, 2026

Where Facts Go Missing: A Layerwise Taxonomy and Per-Layer Attribution of Information Omission in Air-Gapped LLMAgent Pipelines

Air-gapped and on-premises language-model agents can silently omit decision-critical facts at any boundary between source ingestion and final answer generation. We present a nine-layer taxonomy (L0-L8), an instrumented attribution harness, and a conditional omission waterfall that distinguishes deterministic software loss from behavioral non-retrieval. We analyze 75,476 controlled synthetic trials spanning five open-weight model configurations and two inference engines, together with a separate 372-trial real-agent pilot covering FHIR, PubMed, and SEC-EDGAR sources with LangChain and ADK orchestration. The weighted synthetic benchmark yields an omission rate of 0.574 (95% CI: 0.571-0.578); deliberately injected deterministic faults at L0-L3 account for 73.4% of weighted loss under the benchmark allocation. Increasing context length is most strongly associated with omission (odds ratio 7.43, 95% CI: 5.44-10.15). Completed server-profile analyses associate q4 KV cache and scaled RoPE with higher omission. In the real-agent pilot, 57.8% of traces are unsuccessful overall and 50.9% remain unsuccessful after excluding execution errors. These results establish pipeline-level attribution in a controlled stress test, but benchmark allocations, confounded model comparisons, and heuristic behavioral labels do not measure production prevalence or causal architectural effects.
Jun 8, 2026

CARE: A Conformal Safety Layer for Medical Summarization

Large language models (LLMs) are increasingly used for medical summarization but can omit medically important information and introduce unsupported claims. Existing error-detection methods produce heuristic or uncalibrated scores, providing no formal control over missed errors and no principled way to trade off safety against clinician review burden. We introduce Conformal Assessment for Risk Evaluation (CARE), a post-hoc risk-control layer that adds calibrated omission and hallucination annotations without retraining the summarizer. CARE uses scalar conformal risk control (CRC) to bound the probability that a document contains an unflagged hallucinated sentence, and Learn-Then-Test fixed-sequence testing (LTT-FST) to control the expected fraction of true omissions left unsurfaced for review. Omission surfacing depends jointly on sentence importance and summary coverage, a two-dimensional threshold-selection problem; we show that calibrating one gate and then imposing an uncalibrated second gate can invalidate risk control. Across five medical summarization tasks, mean held-out violation over 100 random calibration/test resplits remains at or below the target for both controllers. At α=0.15α=0.15, LTT-FST achieves the lowest review workload on three of five datasets among omission baselines held to the same confidence guarantee. Review workload varies by task and is highest for long, high-compression documents. On 46 clinician-annotated documents, the calibrated hallucination controller flags 88% of clinician-identified hallucinated sentences. In a preliminary study of 75 clinician reviews, assisted review-time omission coverage increased from 50.4% to 79.0% without increasing review time. Overall, CARE provides a principled framework for targeted, risk-controlled review of LLM-generated medical summaries.