eess.SPNov 19, 2026

Lightweight Low-Frequency Non-Intrusive Load Monitoring via Karhunen-Loève Feature Distillation and Temporal Convolutional Networks

Authors: Sanka Peeris, Pandula Thennakoon, Praveen Sumanasekara, Roshan Godaliyadda, Parakrama Ekanayake, Janaka Ekanayake

Organizations: Multidisciplinary AI Research Centre (MARC), University of Peradeniya, Peradeniya 20400, Sri Lanka · Rice University, Houston, TX 77005 USA, and also with Farbe Technologies, Sri Lanka · University of Michigan, Ann Arbor, MI 48109 USA, and also with the Multidisciplinary AI Research Centre (MARC), University of Peradeniya, Peradeniya 20400, Sri Lanka · Multidisciplinary AI Research Centre (MARC), University of Peradeniya, Peradeniya 20400, Sri Lanka and the Department of Electrical and Electronic Engineering, University of Peradeniya, Peradeniya 20400, Sri Lanka

Abstract

Non-Intrusive Load Monitoring (NILM) is a critical enabler for demand-side management which allows for smart grid optimization. A deployment-ready NILM solution necessitates three key features: accurate disaggregation, low-frequency sampling, and low computational cost. This paper proposes a lightweight, edge-oriented NILM framework that combines activity-boundary-aware synthetic data augmentation with Karhunen-Loève Transform (KLT) feature extraction and a Temporal Convolutional Network (TCN). The augmentation stage extracts and recombines complete or near-complete appliance activation segments so that the model can be trained without new fully labeled household aggregates. The KLT filter bank extracts decorrelated, appliance-informed temporal features which are then fed into a compact TCN along with the original aggregate for energy disaggregation. Evaluations on two standard NILM datasets, UK-DALE and REDD, at 10-s sampling and with leave-one-house-out testing, demonstrate that the proposed architecture achieves comparable or superior disaggregation accuracy relative to NILMFormer, BERT4NILM, BiLSTM, and BiGRU. The computational footprint of the framework is 31,009 parameters, the fewest of the five models compared, and on a single CPU thread it needs 2.78 ms per 1000 samples, 84-95% less than the baselines. These results demonstrate a favorable accuracy-efficiency tradeoff for low-frequency smart-meter NILM.

Figures & tables

Explore similar work

Mar 5, 2026

Lightweight and Scalable Transfer Learning Framework for Load Disaggregation

Non-Intrusive Load Monitoring (NILM) aims to estimate appliance-level consumption from aggregate electrical signals recorded at a single measurement point. In recent years, the field has increasingly adopted deep learning approaches; however, cross-domain generalization remains a persistent challenge due to variations in appliance characteristics, usage patterns, and background loads across homes. Transfer learning provides a practical paradigm to adapt models with limited target data. However, existing methods often assume a fixed appliance set, lack flexibility for evolving real-world deployments, remain unsuitable for edge devices, or scale poorly for real-time operation. This paper proposes RefQuery, a scalable multi-appliance, multi-task NILM framework that conditions disaggregation on compact appliance fingerprints, allowing one shared model to serve many appliances without a fixed output set. RefQuery keeps a pretrained disaggregation network fully frozen and adapts to a target home by learning only a per-appliance embedding during a lightweight backpropagation stage. Experiments on three public datasets demonstrate that RefQuery delivers a strong accuracy-efficiency trade-off against single-appliance and multi-appliance baselines, including modern Transformer-based methods. These results support RefQuery as a practical path toward scalable, real-time NILM on resource-constrained edge devices.
Sep 19, 2026

Ask for Any Appliance: A Prompt-Programmable Foundation Model for Non-Intrusive Load Monitoring

Non-intrusive load monitoring (NILM) estimates appliance-level consumption from a whole-home meter, but appliance-specific models and fixed output inventories make coverage costly to extend. We present FM4NILM (Foundation Model for NILM), a single prompt-programmable model that estimates a requested appliance's power trajectory from aggregate measurements, a natural-language description, and optional activation exemplars. A lightweight cadence-aware transformer is pretrained by masked reconstruction on 645k sequences from seven public corpora spanning 1-60 s sampling intervals, then aligned with appliance requests using observation-masked losses for partially labeled households. A Bernoulli-lognormal decoder separates activity detection from conditional power estimation. On held-out households and time periods from REDD, UK-DALE, and REFIT, one frozen text-prompted model serves twelve appliance-corpus requests, achieving 0.556 event F1, 0.625 AUPRC, and the lowest active-window MAE (251.8 W) among seven appliance-specific baselines. Streaming score aggregation raises event F1 to 0.582 with a 60 s aggregation delay. In a separate category-held-out evaluation, adding ten activation exemplars raises microwave AUPRC from 0.132 to 0.214 without parameter updates. Input-intervention ablations probe the model's dependence on appliance requests and aggregate measurements. These results demonstrate competitive disaggregation with one shared model and support extending appliance coverage through prompts and examples rather than additional specialist networks.
Aug 20, 2025

Energy Injection Identification enabled Disaggregation with Deep Multi-Task Learning

Non-Intrusive Load Monitoring (NILM) offers a cost-effective method to obtain fine-grained appliance-level energy consumption in smart homes and building applications. However, the increasing adoption of behind-the-meter (BTM) energy sources such as solar panels and battery storage poses new challenges for conventional NILM methods that rely solely on at-the-meter data. The energy injected from the BTM sources can obscure the power signatures of individual appliances, leading to a significant decrease in NILM performance. To address this challenge, we present DualNILM, a deep multi-task learning framework designed for the dual tasks of appliance state recognition and injected energy identification. Using a Transformer-based architecture that integrates sequence-to-point and sequence-to-sequence strategies, DualNILM effectively captures multiscale temporal dependencies in the aggregate power consumption patterns, allowing for accurate appliance state recognition and energy injection identification. Extensive evaluation on self-collected and synthesized datasets demonstrates that DualNILM maintains an excellent performance for dual tasks in NILM, much outperforming conventional methods. Our work underscores the framework's potential for robust energy disaggregation in modern energy systems with renewable penetration. Synthetic photovoltaic augmented datasets with realistic injection simulation methodology are open-sourced at https://github.com/MathAdventurer/PV-Augmented-NILM-Datasets.