eess.SPNov 19, 2026

Lightweight Low-Frequency Non-Intrusive Load Monitoring via Karhunen-Loève Feature Distillation and Temporal Convolutional Networks

Authors: Sanka Peeris, Pandula Thennakoon, Praveen Sumanasekara, Roshan Godaliyadda, Parakrama Ekanayake, Janaka Ekanayake

Organizations: Multidisciplinary AI Research Centre (MARC), University of Peradeniya, Peradeniya 20400, Sri Lanka · Rice University, Houston, TX 77005 USA, and also with Farbe Technologies, Sri Lanka · University of Michigan, Ann Arbor, MI 48109 USA, and also with the Multidisciplinary AI Research Centre (MARC), University of Peradeniya, Peradeniya 20400, Sri Lanka · Multidisciplinary AI Research Centre (MARC), University of Peradeniya, Peradeniya 20400, Sri Lanka and the Department of Electrical and Electronic Engineering, University of Peradeniya, Peradeniya 20400, Sri Lanka

Abstract

Non-Intrusive Load Monitoring (NILM) is a critical enabler for demand-side management which allows for smart grid optimization. A deployment-ready NILM solution necessitates three key features: accurate disaggregation, low-frequency sampling, and low computational cost. This paper proposes a lightweight, edge-oriented NILM framework that combines activity-boundary-aware synthetic data augmentation with Karhunen-Loève Transform (KLT) feature extraction and a Temporal Convolutional Network (TCN). The augmentation stage extracts and recombines complete or near-complete appliance activation segments so that the model can be trained without new fully labeled household aggregates. The KLT filter bank extracts decorrelated, appliance-informed temporal features which are then fed into a compact TCN along with the original aggregate for energy disaggregation. Evaluations on two standard NILM datasets, UK-DALE and REDD, at 10-s sampling and with leave-one-house-out testing, demonstrate that the proposed architecture achieves comparable or superior disaggregation accuracy relative to NILMFormer, BERT4NILM, BiLSTM, and BiGRU. The computational footprint of the framework is 31,009 parameters, the fewest of the five models compared, and on a single CPU thread it needs 2.78 ms per 1000 samples, 84-95% less than the baselines. These results demonstrate a favorable accuracy-efficiency tradeoff for low-frequency smart-meter NILM.

Figures & tables

Explore similar work

CardsList
  1. Lightweight and Scalable Transfer Learning Framework for Load Disaggregation

    Mar 5, 2026L. E. Garcia-Marrero, G. Petrone, E. MonmassonNon-Intrusive Load MonitoringTransfer Learning

  2. Ask for Any Appliance: A Prompt-Programmable Foundation Model for Non-Intrusive Load Monitoring

    Sep 19, 2026Xudong Wang, Jiacheng Cui, Junyu Xue +2Non-Intrusive Load MonitoringTime-Series Foundation Models

  3. Energy Injection Identification enabled Disaggregation with Deep Multi-Task Learning

    Aug 20, 2025Xudong Wang, Guoming Tang, Junyu Xue +3Non-Intrusive Load MonitoringMulti-Task Learning