eess.IVNov 19, 2026

Physics-Informed Deep Learning for Shear Wave Speed Estimation in MR Elastography

Authors: Stefan Martin, Jakob Schattenfroh, Patrick Schuenke, Felix Frederik Zimmermann, Ingolf Sack, Christoph Kolbitsch, Andreas Kofler

Organizations: Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany · Charité - Universitätsmedizin Berlin, Germany

Abstract

Objective: Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique for mapping biomechanical properties of in vivo tissue, including shear wave speed (SWS), but involves intrinsically slow data acquisition and an ill-posed wave inversion. Instead of relying on handcrafted image priors, we propose a data-driven approach jointly combining image reconstruction and MRE inversion for robust SWS estimation from undersampled k-space data. Methods: Our physics-informed reconstruction framework comprises two blocks: a model-based neural network (NN)-regularized reconstruction module and a phase-gradient inversion (k-MDEV) calculating SWS from the reconstructed images. Concatenating both blocks yields an end-to-end trainable method to estimate SWS directly from measured k-space data. We evaluated the method on retrospectively highly undersampled brain MRE data and compared it to a total variation (TV) minimization-based approach. We assessed the impact of end-to-end training (qualitative images and SWS maps as targets) versus pre-training (qualitative images as targets) and applied the method also to in vivo data. Results: Our approach significantly reduces NRMSE by 30% compared to TV. End-to-end training improves SWS estimation over separate image reconstruction and SWS calculation. Conclusion: Accurate SWS quantification is possible at acceleration factors up to 19. Our method significantly outperforms TV, highlighting the need for data-driven regularization in this challenging MR problem. Further, our approach successfully generalizes to in vivo data. Significance: We present the first end-to-end trainable MRE reconstruction method for estimating SWS maps directly from k-space. NN-based reconstruction can enable rapid stiffness mapping for dynamic studies, functional imaging, and real-time clinical feedback.

Figures & tables

Explore similar work

Jan 17, 2026

Accelerated MR Elastography Using Learned Neural Network Representation

To develop a deep-learning method for achieving fast high-resolution MR elastography from highly undersampled data without the need of high-quality training dataset. We first framed the deep neural network representation as a nonlinear extension of the linear subspace model, then used it to represent and reconstruct MRE image repetitions from undersampled k-space data. The network weights were learned using a multi-level k-space consistent loss. To further enhance reconstruction quality, phase-contrast specific magnitude and phase priors were incorporated, including the similarity of anatomical structures and smoothness of wave-induced harmonic displacement. Experiments were conducted using both 3D gradient-echo spiral and multi-slice spin-echo spiral MRE datasets. Compared to the conventional linear subspace-based approaches, the nonlinear network representation method was able to produce superior image reconstruction with suppressed noise and artifacts from a single in-plane spiral arm per MRE repetition (e.g., 2mm isotropic resolution in 1 min with a total R=10), yielding comparable stiffness estimation to the fully sampled data. This work demonstrated the feasibility of using deep network representations to model and reconstruct MRE images from highly-undersampled data, a nonlinear extension of the subspace-based approaches.
Oct 2, 2026

A hybrid CNN-adjoint optimization framework for reconstruction of viscoelastic tissue properties in magnetic resonance elastography

Magnetic resonance elastography (MRE) is a noninvasive imaging modality for quantifying the viscoelastic properties of soft tissues from shear wave propagation. Recovering the complex-valued shear modulus from measured displacement fields leads to a severely ill-posed inverse problem, particularly in the presence of noise and limited boundary excitations. We investigate adjoint-based optimization, convolutional neural network (CNN) reconstruction, and a hybrid framework combining both approaches. The forward model is based on a scalar form of the modified stationary Stokes system with a complex shear modulus. We establish well-posedness of the forward problem, existence of minimizers, and first-order optimality conditions for the adjoint-based formulation, and implement a nonlinear conjugate-gradient method with Armijo line search. While PDE-constrained optimization can accurately refine coefficient reconstructions, its performance depends strongly on initialization. We therefore construct a two-dimensional CNN that maps complex-valued displacement measurements to spatially varying complex shear modulus fields and provides rapid, informative initial reconstructions. The proposed hybrid method uses the CNN reconstruction to initialize the adjoint-based optimization, yielding faster convergence and improved accuracy. The CNN is trained on coefficient fields containing individual perturbations and tested on both individual and previously unseen combined configurations. Numerical experiments demonstrate that the CNN generalizes to these more challenging configurations, while subsequent PDE-constrained optimization further refines the reconstructed coefficient. These results demonstrate the potential of combining data-driven initialization with physics-based optimization for efficient and accurate MRE reconstruction.
Nov 9, 2026

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

Purpose: To develop a phase-aware self-supervised framework for accelerated high-resolution multi-echo gradient-echo (mGRE) MRI that preserves anatomical detail and complex echo information for quantitative mapping. Methods: We developed multi-stage phase-aware self-supervised reconstruction (MSPR-GRE), integrating progressive k-space expansion with phase estimation and refinement. Sequential unrolled networks reconstruct complex multi-echo images and update echo-dependent phase priors. A relaxation-informed temporal subspace is used for acquisitions with at least four echoes, while shorter echo trains are reconstructed in the image domain. Training uses held-out acquired k-space samples without fully sampled targets. Evaluation included 9.4 T ex vivo mouse-brain data 30um eight-echo and 18um dual-echo) and retrospectively undersampled 7 T AHEAD human-brain data, with supervised ablations. Results:MSPR-GRE reduced artifacts in regions of rapid phase variation and preserved fine mouse-brain anatomy. Across five AHEAD test datasets at R = 4, 8, and 12, it generally improved magnitude-image, T2* map, and QSM metrics, particularly at higher acceleration. At R = 12, fourth-echo magnitude NRMSE was 12.09±\pm0.60% versus 21.55±\pm1.12% for SSDU. Ablations indicated benefits of phase refinement, while supervised experiments supported multi-stage phase-aware reconstruction. Conclusion: MSPR-GRE improves accelerated mGRE reconstruction and quantitative-map agreement without fully sampled training targets. Further validation of generalizability and phase-estimation accuracy is needed.