CryoGaussian: Heterogeneous Cryo-EM Reconstruction Made Explicit with Gaussian Splatting
Authors: Ziwen Wang, Jiajun Fan, Chaoran Cheng, Ruihan Guo, Yanru Qu, Juexiao Zhou, Ge Liu
Organizations: School of Data Science, The Chinese University of Hong Kong, Shenzhen · Siebel School of Computing and Data Science, University of Illinois Urbana-Champaign
Single-particle cryo-electron microscopy (cryo-EM) determines macromolecular structures from noisy particle images. However, rare, transient compositional states and subtle, continuous conformational variation are difficult to resolve. We present CryoGaussian, a Gaussian splatting method for heterogeneous cryo-EM reconstruction that fits an explicit Gaussian density representation directly to the particle images through a differentiable rasterizer rendering orthographic line integrals modulated by the contrast transfer function. The Gaussians are initialized randomly, with their number derived from the estimated spatial support of the molecular density and their minimum size bounded by the Nyquist frequency of the particle images. To capture the compositional and conformational variation across particle images, we learn particle-image and per-Gaussian latents that jointly modulate the base position, amplitude, and scale of each Gaussian. Each structural state is then reconstructed by fitting the Gaussians conditioned on its inferred latent. On CryoBench, CryoGaussian achieves state-of-the-art reconstruction accuracy for both compositional and conformational heterogeneity. On experimental data, it resolves a rare compositional state of the 50S ribosomal subunit (class C4, 1.3% of particles) with rRNA helix 68 docked in the absence of the central protuberance, and continuous conformational motion of the SF3b and helicase subcomplexes of the pre-catalytic spliceosome. We further optimize the rasterizer for additive cryo-EM projection, reducing training time by 12.8-28.0×. Reconstructed density maps are available at https://huggingface.co/datasets/ZiwenWang28/CryoGaussian.
Figures & tables
Figure 1: CryoGaussian overview. (a) The number of randomly initialized Gaussians is derived from the estimated spatial support of the molecular density (Appendix F ), and the pixel size sets their minimum size. (b) Separate MLPs decode position, amplitude, and scale modulations of each Gaussian from the concatenated particle-image and per-Gaussian latents (Appendix A ). (c) Heterogeneity is estimated by jointly learning these latents, and compositional and conformational states are then reconstructed from the inferred latents.
Dataset
Gradient accumulation
Projection scheduling
8 GPUs
Time (ms)
Memory saved (%)
IgG-1D
2.39 ×
7.69 ×
5.41 ×
17.31
7.98
IgG-RL
2.27 ×
7.96 ×
5.79 ×
34.33
9.56
Ribosembly
2.46 ×
11.37 ×
6.48 ×
73.89
8.97
Tomotwin-100
2.62 ×
10.23 ×
5.14 ×
72.90
9.74
Spike-MD
2.38 ×
6.68 ×
6.16 ×
216.49
10.17
EMPIAR-10076
2.35 ×
5.43 ×
6.18 ×
520.19
9.63
Table 1: Training efficiency. On one GPU, CryoGaussian achieves multiplicative speedups over the CryoSplat rasterizer [ 8 ] through per-Gaussian gradient accumulation and projection scheduling. On eight NVIDIA RTX PRO 6000 Blackwell GPUs, we measure its further speedup, time per iteration, and memory saved (Table 6 ).
Figure 2: Heterogeneous reconstruction on CryoBench. Representative reconstructed densities (top) and UMAP projections [ 37 ] of inferred latents (bottom) are linked by matching numbers. Colors indicate the ground-truth IgG-1D dihedral angle, IgG-RL Fab distance, Ribosembly assembly state, Tomotwin-100 molecular mass, and Spike-MD collective variable CV1. Spike-MD labels indicate receptor-binding domain opening. All 16 Ribosembly states are shown, named as in Qin et al. [ 46 ] . Appendix D.1 shows all evaluated reconstructions with reference densities and FSC curves (Figures 8 – 12 ), densities of latent clusters (Figure 13 ), and latent metrics (Figures 5 – 7 ).
Method
IgG-1D
IgG-RL
Ribosembly
Tomotwin-100
Spike-MD
Average of means
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Conf.
Comp.
All
CryoDRGN
0.366 (0.003)
0.366
0.349 (0.008)
0.348
0.415 (0.019)
0.415
0.321 (0.034)
0.322
0.340 (0.009)
0.340
0.352
0.368
0.358
CryoDRGN-AI-fixed
0.366 (0.001)
0.366
0.355 (0.007)
0.354
0.372 (0.032)
0.374
0.206 (0.041)
0.212
0.301 (0.012)
0.304
0.341
0.289
0.320
OPUS-DSD
0.340 (0.006)
0.341
0.346 (0.029)
0.349
0.372 (0.046)
0.382
0.256 (0.038)
0.266
0.228 (0.030)
0.242
0.305
0.314
0.308
3DFlex
0.336 (0.002)
0.336
0.339 (0.007)
0.339
–
–
–
–
0.304 (0.010)
0.306
–
–
–
3DVA
0.351 (0.003)
0.351
0.341 (0.006)
0.341
0.375 (0.038)
0.372
0.095 (0.040)
0.083
0.324 (0.010)
0.325
0.339
0.235
0.297
Table 2: Per-conformation FSC AUC on CryoBench. Mean (standard deviation) and median across evaluated reference states, with background masking (Appendix C.2 ). Higher is better. Bold and underline mark the best and second best per column, including ties at the displayed precision. Conf., Comp., and All average the means over the conformational (IgG-1D, IgG-RL, Spike-MD), the compositional (Ribosembly, Tomotwin-100), and all five datasets, for methods with values on every dataset, so that averages are comparable across methods. For CryoSPIRE ∗ , values are taken directly from its publication (Appendix B.4 ) because we were unable to find a publicly available implementation. CryoHype and CryoKRAQEN have published per-image values only (Table 3 ). Dashes mark results not included.
Method
IgG-1D
IgG-RL
Ribosembly
Tomotwin-100
Spike-MD
Average of means
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Conf.
Comp.
All
CryoDRGN
0.351 (0.028)
0.356
0.331 (0.016)
0.333
0.412 (0.023)
0.415
0.316 (0.046)
0.321
0.340 (0.009)
0.340
0.341
0.364
0.350
CryoDRGN-AI-fixed
0.364 (0.002)
0.364
0.348 (0.012)
0.350
0.372 (0.032)
0.375
0.202 (0.044)
0.207
0.301 (0.012)
0.303
0.338
0.287
0.317
OPUS-DSD
0.335 (0.026)
0.339
0.343 (0.016)
0.346
0.362 (0.083)
0.382
0.237 (0.049)
0.251
0.229 (0.027)
0.242
0.302
0.300
0.301
3DFlex
0.335 (0.003)
0.335
0.337 (0.007)
0.337
–
–
–
–
0.304 (0.011)
0.306
–
–
–
3DVA
0.349 (0.004)
0.350
0.333 (0.014)
0.335
0.375 (0.038)
0.375
0.088 (0.040)
0.077
0.324 (0.010)
0.323
0.335
0.232
0.294
Table 3: Per-image FSC AUC on CryoBench. Mean (standard deviation) and median across evaluated particle images, with background masking (Appendix C.2 ); notation as in Table 2 . For methods marked ∗ and ∗∗ , values are taken directly from their publications (Appendix B.4 ), ∗ because we were unable to find a publicly available implementation and ∗∗ because we were unable to find implementations of the mechanisms of CryoHype for the other datasets. Tables 8 and 15 report seed variability and unmasked FSC AUC.
Figure 3: Compositional heterogeneity in the assembling 50S ribosomal subunit (EMPIAR-10076). (a, c) UMAP projections of the inferred latents, colored by published major and minor class assignments [ 11 ] ; black points mark class centers. The inset locates the 1,113 particle images of class C4 [ 75 ] . (b) C4 and E4 densities. (d) Major assembly classes B–E and the 70S class A. Dashed lines trace the outline of the mature 50S subunit, and red ellipses mark rRNA helix 68 (H68). CP, central protuberance; LSU, large subunit. Appendix D.2 shows the twelve minor classes C1–C3, D1–D4, and E1–E5 with map-to-map FSC against the deposited reconstructions (Figure 14 ) and the CryoSPARC refinement of C4 (Figure 15 ). Appendix E.7 presents particle selection by CryoGaussian (Figures 20 – 22 ).
Figure 4: Conformational variation in the pre-catalytic spliceosome (EMPIAR-10180). (a) Principal-component projections of inferred latents, with five numbered positions along PC1 (top) and PC2 (bottom). EV denotes the fraction of latent variance explained by each component. (b) Densities reconstructed at positions 1–5, ordered from left to right in each row. Dashed outlines reproduce each row’s first density; arrows indicate the direction of conformational change. Appendix D.2 analyzes the full particle stack (Figure 16 ).
Appendix figures & tables33 assets
Supplementary material from the paper’s appendix.
Appendix
Dataset
Number of particle images
Reference states
Image dimensions (pixels)
Pixel size (Å/pixel)
Signal-to-noise ratio
IgG-1D
100,000
100
128×128
3.0
0.01
IgG-RL
100,000
100
128×128
3.0
0.01
Ribosembly
335,240
16
128×128
3.0
0.01
Tomotwin-100
100,000
100
128×128
4.5
0.01
Spike-MD
100,000
46,789
256×256
1.5
0.1
Appendix
Table 4: CryoBench datasets used in the main comparison. Dimensions and pixel sizes describe the processed images; the signal-to-noise ratio identifies the noise condition of the released dataset. For Spike-MD, reference states are the 46,789 distinct molecular-dynamics configurations reported by CryoBench.
Dataset
Sample
Deposited particle images
Image dimensions (pixels)
Pixel size (Å/pixel)
EMPIAR-10076 [ 11 ]
Assembling 50S ribosomal subunit
131,899
320×320
1.31
EMPIAR-10180 [ 42 ]
Pre-catalytic spliceosome
327,490
320×320
1.699
Appendix
Table 5: Experimental particle-image datasets. Particle selection and preprocessing are described in Appendix B.1 . Pixel sizes refer to the deposited particle images.
Dataset
Box
Estimated Gaussians
Global batch
Time per iteration (ms)
Training time (h)
Forward (particles/s)
Peak allocated (GiB/GPU)
Gradient accumu- lation
Projection sched- uling
8 GPUs
Memory saved (%)
EMPIAR-10180
256
448,148
256
376.64
6.83
956.3
12.14
2.64 ×
8.51 ×
5.59 ×
9.95
EMPIAR-10076 (CryoDRGN-filtered)
256
513,705
256
520.19
8.50
841.1
14.14
2.35 ×
5.43 ×
6.18 ×
9.63
EMPIAR-10076 (CryoGaussian-filtered)
256
463,802
256
464.01
7.63
950.5
12.78
2.25 ×
5.58 ×
6.12 ×
9.86
IgG-1D (SNR 0.01)
128
10,316
256
17.31
0.30
27,250.4
0.33
2.39 ×
7.69 ×
5.41 ×
7.98
IgG-1D (SNR 0.005)
128
10,736
256
17.94
0.31
25,501.7
0.34
2.44 ×
7.47 ×
5.75 ×
8.28
IgG-1D (SNR 0.001)
128
31,338
256
36.51
0.64
9,738.0
0.90
2.36 ×
9.65 ×
6.19 ×
8.94
Appendix
Table 6: Training time and memory of CryoGaussian on eight NVIDIA RTX PRO 6000 Blackwell GPUs. We report global batch sizes. Estimated numbers of Gaussians at τ=0.02 are rounded to the nearest integer. Peak allocated memory per GPU is reported with the forward workspaces retained, and the memory saved is the reduction of this peak when the workspaces are released before the backward pass (Appendix G.3 ). The speedups of per-Gaussian gradient accumulation, projection scheduling, and eight GPUs over one GPU and the memory saved are those of Table 1 , measured in the same way for the other configurations.
Method
Ribosembly
Tomotwin-100
ARI
AMI
ARI
AMI
CryoDRGN
0.873
0.935
0.956
0.983
CryoDRGN-AI-fixed
0.624
0.771
0.791
0.906
OPUS-DSD
0.891
0.934
0.500
0.781
3DVA
0.666
0.823
0.058
0.335
RECOVAR
0.968
0.976
0.315
0.649
Appendix
Table 7: Clustering accuracy on Ribosembly and Tomotwin-100. Adjusted Rand index (ARI) and adjusted mutual information (AMI) between ground-truth labels and k -means cluster assignments of the inferred particle-image latents, with k equal to the number of ground-truth states (16 for Ribosembly and 100 for Tomotwin-100). Higher is better. Bold and underline mark the best and second best per column. The compared methods are those of Tables 2 and 3 with publicly available implementations. CryoGaussian values are the mean (standard deviation) over 10 random seeds.
Dataset
Per-image mean FSC AUC
Per-conformation mean FSC AUC
IgG-1D
0.3976 ± 0.0006 (0.3962–0.3982)
0.4024 ± 0.0004 (0.4019–0.4032)
IgG-RL
0.3673 ± 0.0011 (0.3656–0.3685)
0.3879 ± 0.0009 (0.3861–0.3892)
Ribosembly
0.4326 ± 0.0007 (0.4321–0.4339)
0.4328 ± 0.0008 (0.4313–0.4338)
Tomotwin-100
0.3366 ± 0.0012 (0.3353–0.3387)
0.3373 ± 0.0012 (0.3359–0.3392)
Spike-MD
0.3647 ± 0.0008 (0.3634–0.3654)
0.3651 ± 0.0008 (0.3640–0.3669)
Appendix
Table 8: Variability of CryoGaussian across training seeds on CryoBench. Mean ± standard deviation across 10 training seeds of the mean FSC AUC with background masking, with the range across seeds in parentheses. Seeds vary the random initialization of the Gaussians and latents and the order of particle images, and heterogeneity estimation and per-state reconstruction are both rerun for each seed.
Figure 5: Heterogeneity estimation on CryoBench. Neighborhood similarity as a function of the neighborhood radius (top row) and information imbalance (bottom row) between inferred latents and the ground-truth heterogeneity embedding on (a) IgG-1D, (b) IgG-RL, (c) Ribosembly, (d) Tomotwin-100, and (e) Spike-MD, presented in the format of Figures 2d, 4d, 6d, 7d, and S24 of the CryoBench paper [ 24 ] . Stars denote CryoGaussian.
Figure 6: Pose information imbalance on CryoBench. Information imbalance between inferred latents and ground-truth rotations on (a) IgG-1D, (b) IgG-RL, (c) Ribosembly, (d) Tomotwin-100, and (e) Spike-MD, in full view (top row) and enlarged near (1,1) (bottom row), presented in the format of Figure S22 of the CryoBench paper [ 24 ] .
Figure 7: CTF information imbalance on CryoBench. Information imbalance between inferred latents and CTF parameters on (a) IgG-1D, (b) IgG-RL, (c) Ribosembly, (d) Tomotwin-100, and (e) Spike-MD, in full view (top row) and enlarged near (1,1) (bottom row), presented in the format of Figure S23 of the CryoBench paper [ 24 ] .
Figure 8: IgG-1D reconstruction at SNR 0.01. (a) CryoGaussian densities reconstructed at the inferred latents for 100 particle images (Ours), each paired with its reference density (G.T., gray). Reconstructed densities are colored by the ground-truth dihedral angle. (b) UMAP projection of inferred latents with the same color scale. (c) Per-image FSC (top) and per-conformation FSC (bottom), evaluated with background masking (left) and without masking (right). Solid curves show the mean, and shaded regions cover the 5th–95th percentiles across 100 evaluated particle images or 100 reference states, respectively.
Figure 9: IgG-RL reconstruction. (a) CryoGaussian densities reconstructed at the inferred latents for 100 particle images (Ours), paired with their reference densities (G.T., gray). Colors indicate the distance from the Fab domain to the center of mass of the rest of the structure. (b) UMAP projection of inferred latents with the same color scale. (c) Per-image FSC (top) and per-conformation FSC (bottom), with background masking (left) and without masking (right). Solid curves show the mean, and shaded regions cover the 5th–95th percentiles across 100 evaluated particle images or 100 reference states, respectively.
Figure 10: Ribosembly reconstruction. (a) CryoGaussian densities reconstructed at inferred latents for particle images from all 16 reference assembly states (Ours), paired with their reference densities (G.T., gray). (b) UMAP projection of inferred latents. Colors in (a) and (b) identify reference assembly states. (c) Per-image FSC (top) and per-conformation FSC (bottom), with background masking (left) and without masking (right). Solid curves show the mean, and shaded regions cover the 5th–95th percentiles across 101 evaluated particle images in the top row and 16 reference states in the bottom row.
Figure 11: Tomotwin-100 reconstruction. (a) Per-image CryoGaussian densities (Ours) and paired reference densities (G.T., gray) for 100 distinct complexes. (b) UMAP projection of inferred latents; colors in (a) and (b) indicate molecular mass in kDa. (c) Per-image FSC (top) and per-conformation FSC (bottom), with background masking (left) and without masking (right). Solid curves show the mean, and shaded regions cover the 5th–95th percentiles across 100 evaluated particle images or 100 reference complexes, respectively.
Figure 12: Spike-MD reconstruction. (a) CryoGaussian densities reconstructed at the inferred latents for 100 selected particle images (Ours), paired with their reference densities (G.T., gray) and colored by collective variable CV1. (b) UMAP projections of inferred latents, colored by CV1 (top) and CV2 (bottom), with collective-variable definitions from Wieczór et al. [ 65 ] . (c) Per-image FSC (top) and per-conformation FSC (bottom), with background masking (left) and without masking (right). Solid curves show the mean, and shaded regions cover the 5th–95th percentiles across 100 evaluated particle images or their reference configurations, respectively.
Figure 13: Representative densities selected by latent clustering. For each dataset and noise condition, inferred latents are partitioned by k -means into 20 clusters, or 16 for Ribosembly. The observed latent nearest to each cluster center is decoded to obtain a representative density. Each dataset block shows these densities alongside the UMAP projection, with colored markers locating the selected latents. Matching colors link each density to its marker and indicate cluster identity within that dataset.
Figure 14: Assembly-state reconstruction using the CryoDRGN particle selection for EMPIAR-10076. The model is trained on 87,327 particle images. (a) Reconstructed densities for the twelve minor classes C1–C3, D1–D4, and E1–E5, with dashed lines tracing the outline of the mature 50S subunit. (b) Map-to-map FSC between CryoGaussian densities and the corresponding deposited reconstructions [ 11 ] , for class A and the thirteen assembly classes B–E5. Horizontal dashed lines indicate FSC values of 0.5 and 0.143. (c) UMAP projection of inferred latents colored by published class assignments. (d) The same projection with each class highlighted separately. Colors are shared across panels (b)–(d). Representative-latent selection and map comparison are described in Appendix C.3 .
Figure 15: Identification and homogeneous refinement of the 50S assembly intermediate C4. The left and right columns use the CryoDRGN-filtered and CryoGaussian-filtered particles, respectively. (a, b) CryoSPARC refinement uses the 1,113 particles of the released C4 particle selection [ 75 ] (a) and their intersection with the CryoGaussian-filtered particle set (1,019 particles; b). (c) Identification of this intermediate in the CryoGaussian latent space, without the released selection. UMAP projections of the inferred latents are colored by published major class assignments; black points mark class centers. Gray boxes mark the regions enlarged on the right, and black polygons outline the selected particles. (d, e) CryoSPARC refinement uses the 1,062 (d) and 954 (e) particles selected in (c). Panels (a), (b), (d), and (e) each show the CryoGaussian density, the CryoSPARC density obtained by homogeneous refinement of the corresponding selected particle images, and FSC curves. Blue curves show gold-standard FSC between independent CryoSPARC half-maps; orange curves show map-to-map FSC between the displayed CryoGaussian and CryoSPARC densities. Horizontal dashed lines indicate FSC values of 0.5 and 0.143. Dashed lines trace the outline of the mature 50S subunit, and red ellipses mark rRNA helix 68 (H68).
Figure 16: Latent-space analysis of the full EMPIAR-10180 particle stack. A four-dimensional model is trained on 327,489 particle images at 128×128 pixels. (a) UMAP projection of inferred latents, with 20 k -means clusters numbered 1–20. Five selected groups are colored to match the reconstructed densities in (b); the other groups are gray. (b) Representative densities from two subdivisions of the largest cluster (i, ii), a cluster with poorly resolved density (iii), a cluster lacking density in the SF3b region (iv), and a cluster with additional density near the U2 core (v). (c) Representative densities for all 20 clusters and the two subdivisions 14a and 14b, with particle counts below each density. Representative-latent selection is described in Appendix C.3 . This full-stack analysis is separate from the CryoDRGN-filtered particle subset used in Figure 4 .
Figure 17: Sensitivity to the relative density threshold on IgG-1D. Heterogeneity estimation on IgG-1D at SNR 0.01 with τ∈{0.01,0.02,0.03,0.04,0.05,0.10} for estimating the number of Gaussians. UMAP projections of inferred latents, colored by the ground-truth dihedral angle, are shown on the left; corresponding neighborhood-similarity curves are shown on the right, following Appendix C.1 . The default threshold τ=0.02 yields the highest neighborhood similarity among the tested values. The UMAP projections retain an ordered loop for thresholds from 0.01 to 0.05, whereas τ=0.10 produces a fragmented projection and lower neighborhood similarity.
τ
Dataset
0.01
0.02
0.03
0.04
0.05
0.10
IgG-1D
Gaussians
16,111
10,316
9,231
8,359
7,598
4,542
Per-image, mean (std)
0.385 (0.007)
0.397 (0.004)
0.390 (0.006)
0.384 (0.009)
0.376 (0.013)
0.361 (0.021)
Per-image, median
0.386
0.398
0.391
0.385
0.379
0.366
Per-conformation, mean (std)
0.392 (0.002)
0.402 (0.001)
0.397 (0.001)
0.391 (0.002)
0.384 (0.003)
0.369 (0.004)
Per-conformation, median
0.392
0.402
0.397
0.391
0.385
0.371
Appendix
Table 9: Sensitivity to the relative density threshold τ on CryoBench. τ selects the estimated spatial support of the density in the CTF-weighted backprojection, and the number of Gaussians follows from the space–bandwidth product of this support (Section 2.2 ). For each τ , the number of Gaussians and the per-image and per-conformation FSC AUC with background masking are reported as in Tables 2 and 3 , which correspond to the default τ=0.02 . Bold marks the best per row.
Figure 18: Ablation of the Gaussian FWHM constraint on IgG-1D. Heterogeneity estimation is evaluated at SNR 0.01 and 0.001 with and without the constraint in Equation ( 5 ), denoted “physical clamp” in the figure. Left: UMAP projections of inferred latents, colored by the ground-truth dihedral angle. Right: Neighborhood similarity, measured as the percentage of matching neighbors (pMN) between the inferred latents and the ground-truth heterogeneity embedding, following Appendix C.1 . The constraint yields higher pMN across the displayed neighborhood radii at both noise levels. Colors denote the constraint setting, and line styles denote SNR.
Dataset
FWHM constraint
Per-image
Per-conformation
Mean (std)
Median
Mean (std)
Median
IgG-1D
With
0.397 (0.004)
0.398
0.402 (0.001)
0.402
Without
0.372 (0.013)
0.374
0.386 (0.005)
0.386
IgG-RL
With
0.366 (0.020)
0.370
0.387 (0.010)
0.387
Without
0.342 (0.033)
0.347
0.370 (0.018)
0.371
Ribosembly
With
0.432 (0.014)
0.432
0.432 (0.016)
0.432
Appendix
Table 10: Ablation of the Gaussian FWHM constraint on CryoBench. Mean (standard deviation) and median FSC AUC with background masking across evaluated particle images (per-image) and reference states (per-conformation) with and without the constraint in Equation ( 5 ). The results with the constraint correspond to Tables 2 and 3 . Higher is better. Bold marks the best per dataset and column.
Figure 19: Ablation of Gaussian initialization on IgG-1D. Heterogeneity estimation is evaluated at SNR 0.01 and 0.001 using random initialization or Gaussian positions sampled from a consensus density optimized without latents on all particle images. Consensus initialization uses density-weighted sampling without replacement over thresholded voxels, as detailed in Appendix E.3 . Left: UMAP projections of inferred latents, colored by the ground-truth dihedral angle. Right: Neighborhood similarity, measured as the percentage of matching neighbors (pMN) between the inferred latents and the ground-truth heterogeneity embedding, plotted against neighborhood radius as a percentage of the 20,000-image evaluation subset (Appendix C.1 ). Higher pMN indicates better preservation of reference conformational neighborhoods. Colors denote Gaussian initialization, and line styles denote SNR. Random initialization yields higher pMN across the evaluated neighborhood radii at both noise levels.
Dataset
Strategy
Per-image
Per-conformation
Mean (std)
Median
Mean (std)
Median
IgG-1D
Heterogeneity estimation alone
0.381 (0.008)
0.381
0.390 (0.004)
0.390
Per-state reconstruction continued from Θ1
0.387 (0.007)
0.389
0.395 (0.003)
0.394
Per-state reconstruction from randomly initialized Θ2
0.397 (0.004)
0.398
0.402 (0.001)
0.402
IgG-RL
Heterogeneity estimation alone
0.358 (0.027)
0.362
0.379 (0.020)
0.378
Per-state reconstruction continued from Θ1
0.361 (0.024)
0.366
0.382 (0.018)
0.381
Appendix
Table 11: Per-state reconstruction strategies on CryoBench. Mean (standard deviation) and median FSC AUC with background masking across evaluated particle images (per-image) and reference states (per-conformation) for three ways of obtaining per-state densities at the same total number of iterations. Heterogeneity estimation alone optimizes Θ1 and the latents jointly and evaluates Θ1 at the inferred latents. Per-state reconstruction continued from Θ1 continues optimizing Θ1 conditioned on the inferred latents. Per-state reconstruction from randomly initialized Θ2 follows Section 2.3 and corresponds to Tables 2 and 3 . Higher is better. Bold marks the best per dataset and column, including ties at the displayed precision.
Decoders
IgG-1D
IgG-RL
Ribosembly
Tomotwin-100
Spike-MD
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Position
0.343 (0.010)
0.344
0.309 (0.024)
0.306
0.305 (0.047)
0.308
0.208 (0.071)
0.204
0.287 (0.028)
0.282
Amplitude
0.358 (0.009)
0.356
0.327 (0.020)
0.327
0.360 (0.042)
0.362
0.259 (0.054)
0.266
0.308 (0.023)
0.307
Scale
0.323 (0.017)
0.320
0.286 (0.033)
0.286
0.335 (0.052)
0.334
0.237 (0.068)
0.232
0.269 (0.029)
0.271
Rotation
0.314 (0.018)
0.312
0.278 (0.036)
0.280
0.299 (0.048)
0.300
0.201 (0.071)
0.195
0.265 (0.033)
0.261
Position and amplitude
0.394 (0.003)
0.394
0.379 (0.015)
0.378
0.421 (0.022)
0.420
0.321 (0.045)
0.320
0.356 (0.018)
0.356
Appendix
Table 12: Combinations of Gaussian attribute decoders on CryoBench, per-conformation FSC AUC. Mean (standard deviation) and median FSC AUC with background masking across evaluated reference states for all 15 combinations of the position, amplitude, scale, and rotation decoders, grouped by the number of decoders (Appendix E.5 ). Each row lists the decoders used, and attributes without a decoder keep their base values (Section 2.3 and Appendix A ). The combination of the position, amplitude, and scale decoders is the configuration of CryoGaussian and corresponds to Table 2 . Higher is better. Bold marks the best per column.
Decoders
IgG-1D
IgG-RL
Ribosembly
Tomotwin-100
Spike-MD
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Position
0.334 (0.017)
0.333
0.287 (0.041)
0.290
0.305 (0.052)
0.306
0.207 (0.076)
0.202
0.287 (0.028)
0.283
Amplitude
0.348 (0.015)
0.351
0.303 (0.035)
0.303
0.356 (0.041)
0.353
0.254 (0.056)
0.252
0.308 (0.022)
0.307
Scale
0.313 (0.024)
0.320
0.263 (0.050)
0.267
0.332 (0.055)
0.327
0.235 (0.063)
0.234
0.269 (0.030)
0.270
Rotation
0.305 (0.026)
0.311
0.255 (0.052)
0.260
0.299 (0.051)
0.297
0.198 (0.076)
0.193
0.264 (0.032)
0.261
Position and amplitude
0.389 (0.008)
0.387
0.357 (0.026)
0.355
0.420 (0.022)
0.421
0.322 (0.042)
0.321
0.356 (0.017)
0.355
Appendix
Table 13: Combinations of Gaussian attribute decoders on CryoBench, per-image FSC AUC. Mean (standard deviation) and median FSC AUC with background masking across evaluated particle images for all 15 combinations of the position, amplitude, scale, and rotation decoders, grouped by the number of decoders (Appendix E.5 ). Each row lists the decoders used, and attributes without a decoder keep their base values (Section 2.3 and Appendix A ). The combination of the position, amplitude, and scale decoders is the configuration of CryoGaussian and corresponds to Table 3 . Higher is better. Bold marks the best per column.
dz
df
IgG-1D
IgG-RL
Ribosembly
Tomotwin-100
Spike-MD
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Mean (std)
Median
Per-image
2
24
0.380 (0.008)
0.381
0.341 (0.028)
0.343
0.422 (0.018)
0.423
0.323 (0.042)
0.328
0.342 (0.017)
0.344
4
24
0.397 (0.004)
0.398
0.366 (0.020)
0.370
0.432 (0.014)
0.432
0.335 (0.035)
0.341
0.364 (0.012)
0.366
8
24
0.390 (0.007)
0.390
0.358 (0.025)
0.360
0.418 (0.024)
0.419
0.315 (0.043)
0.318
0.358 (0.016)
0.361
10
24
0.385 (0.010)
0.385
0.349 (0.027)
0.355
0.405 (0.030)
0.408
0.310 (0.049)
0.313
0.354 (0.022)
0.356
Appendix
Table 14: Latent dimensions on CryoBench. Mean (standard deviation) and median FSC AUC with background masking across evaluated particle images (per-image) and reference states (per-conformation) for particle-image latent dimension dz and per-Gaussian latent dimension df , with the settings of Section 3 otherwise unchanged. dz=4 and df=24 is the configuration of CryoGaussian and corresponds to Tables 2 and 3 . Higher is better. Bold marks the best per column.
Figure 20: Particle filtering and reconstruction of EMPIAR-10076 with CryoGaussian. (a, b) Inferred latents from one- and four-dimensional models trained on all 131,899 particle images: a latent histogram with a kernel-density estimate (a) and a UMAP projection (b). (c, d) The same representations colored by published class assignments [ 11 ] . The vertical dashed line in (c) marks the lower boundary of the excluded latent interval; the dashed contour in (d) identifies the excluded Gaussian-mixture component. The intersection of the two retained particle sets contains 97,651 images, of which a random 90% (87,885 images) are used for subsequent reconstruction. (e, g) Reconstructed densities for assembly classes B–E and the 70S class A. (f, h) Inferred latents colored by major and minor class assignments; the inset identifies the released C4 particle selection [ 75 ] . (i) C4, E4, and E5 densities. (j) Homogeneous reconstruction of the selected C4 particle images with CryoSPARC. Dashed lines trace the outline of the mature 50S subunit, and red ellipses mark H68. Filtering and reconstruction settings are given in Appendices B.1 and C.3 .
Figure 21: Assembly-state reconstruction using the CryoGaussian particle selection for EMPIAR-10076. The model is trained on 87,885 particle images selected as described in Figure 20 . (a) Reconstructed densities for C1–C3, D1–D4, and E1–E5, with dashed lines tracing the outline of the mature 50S subunit. (b) Map-to-map FSC against the corresponding deposited reconstructions [ 11 ] , including classes A and B. Horizontal dashed lines indicate FSC values of 0.5 and 0.143. (c, d) UMAP projections colored by published class assignments, shown jointly (c) and with one class highlighted at a time (d). Colors are shared across panels (b)–(d). Evaluation follows Figure 14 .
Figure 22: Assembly-state comparison on EMPIAR-10076. Columns show reconstructed densities for the major assembly classes B–E. Rows correspond to CryoDRGN (top), CryoGaussian using the CryoDRGN-filtered particle subset (middle), and CryoGaussian using the CryoGaussian-filtered subset (bottom). Dashed lines trace the outline of the mature 50S subunit. Red ellipses, drawn at corresponding positions in all three rows of each column, mark regions in which the CryoDRGN density is fragmented and noise-like, whereas both CryoGaussian reconstructions exhibit continuous density. Particle selection is described in Appendix B.1 .
Figure 23: Noise sensitivity of CryoGaussian on IgG-1D. (a–c) UMAP projections of inferred latents at SNR 0.01, 0.005, and 0.001, respectively, colored by the ground-truth dihedral angle. (d) Masked per-image FSC between reconstructed and reference densities. Solid curves show the mean, and shaded regions cover the 5th–95th percentiles across 100 evaluated particle images. (e) Mean per-image FSC AUC as a function of SNR for CryoGaussian and the compared methods. (f, g) Neighborhood similarity, averaged over neighborhood radii of 1–20% of the evaluation subset, and information imbalance of the inferred latents at the three noise levels. (h, i) Corresponding comparisons with the other methods at SNR 0.01, as in Figure 5 (a). The legend is shared by (e), (h), and (i), with stars denoting CryoGaussian.
Figure 24: IgG-1D reconstruction at SNR 0.005. (a) Per-image reconstructed densities and paired reference densities. (b) UMAP projection of inferred latents, colored by the ground-truth dihedral angle as in Figure 8 . (c) Per-image FSC (top) and per-conformation FSC (bottom), with background masking (left) and without masking (right). Curves and shading show the mean and 5th–95th percentiles across 100 evaluated particle images or 100 reference states, respectively.
Figure 25: IgG-1D reconstruction at SNR 0.001. (a) Per-image reconstructed densities and paired reference densities. (b) UMAP projection of inferred latents, colored by the ground-truth dihedral angle as in Figure 8 . (c) Per-image FSC (top) and per-conformation FSC (bottom), with background masking (left) and without masking (right). Curves and shading show the mean and 5th–95th percentiles across 100 evaluated particle images or 100 reference states, respectively.
Dataset
Evaluation
Masked
Unmasked
Mean (std)
Median
Min–max
Mean (std)
Median
Min–max
IgG-1D (SNR 0.01)
Per-image
0.397 (0.004)
0.398
0.382–0.404
0.397 (0.004)
0.398
0.382–0.403
Per-conformation
0.402 (0.001)
0.402
0.398–0.404
0.401 (0.001)
0.401
0.397–0.404
IgG-1D (SNR 0.005)
Per-image
0.391 (0.012)
0.394
0.296–0.400
0.391 (0.012)
0.394
0.296–0.399
Per-conformation
0.398 (0.001)
0.398
0.394–0.402
0.397 (0.002)
0.397
0.393–0.401
IgG-1D (SNR 0.001)
Per-image
0.302 (0.030)
0.316
0.205–0.336
0.292 (0.030)
0.303
0.200–0.331
Appendix
Table 15: Masked and unmasked FSC AUC for CryoGaussian on CryoBench. We report the mean (standard deviation), median, minimum, and maximum across evaluated particle images for per-image FSC and reference states for per-conformation FSC (Appendix C.2 ).
Cryo-electron microscopy reconstructs biological structures from images of frozen specimens, from cellular volumes to atomic-resolution molecular models.
Single-particle cryo-electron microscopy (cryo-EM) has become a widely adopted technique for biomolecular structure determination. The conventional cryo-EM computational pipeline first combines many particle images to reconstruct an electrostatic potential (ESP) map and then fits an atomic model to the recovered map. Density reconstruction has high sample complexity, requiring large numbers of particle images and making structure determination high-cost and low-throughput, particularly for heterogeneous samples. Downstream atomic model building, in turn, becomes increasingly difficult as the resolution of the reconstructed map deteriorates. Protein structure prediction models provide strong sequence-derived priors on atomic structure, and experiment-guided approaches can use these priors to recover structures consistent with experimental measurements. Yet, in cryo-EM, such priors are typically integrated only after density reconstruction during atomic model fitting. We introduce Fold'EM, an inference-time framework that combines priors from protein generative models directly with cryo-EM particle images to determine atomic models from a small number of single particle images, bypassing both intermediate density reconstruction and downstream model building against the reconstructed map. Across synthetic and experimental cryo-EM datasets, Fold'EM recovers accurate atomic structures both with known particle orientations and in an ab-initio setting where orientations are inferred jointly with structure. In heterogeneous datasets, Fold'EM further resolves distinct conformational states from mixed particle populations without separately reconstructing a density map and building an atomic model for each state. We believe these results open new avenues for structure determination in the low-sample regime and for characterizing low-population conformational states directly from cryo-EM particles.
Advaith Maddipatla, Märt-Erik Mäeots, Marco Pegoraro +5
Institute of Science and Technology Austria · University of Zurich · Frankfurt Institute for Advanced Studies +2
Understanding biomolecular function requires characterizing three-dimensional structure and conformational variability, for which cryogenic electron microscopy (cryo-EM) is a powerful tool. Cryo-EM produces noisy two-dimensional particle images in which molecular structure, particle pose, and imaging conditions are jointly encoded. Recovering biological information from these observations spans inverse problems including pose estimation, heterogeneity analysis, and reconstruction. These tasks are usually addressed independently despite shared protein structure and image formation, motivating a common representation across inverse problems. Since biologically meaningful differences may be spatially localized, we study self-distillation with complementary global and masked patch objectives. Because experimental dataset discrimination can reflect acquisition-specific cues, we develop controlled synthetic and experimental evaluations and find that structural discrimination benefits from dense spatial features. We introduce the EMber family of vision transformers, pre-trained on >50 million experimental particle images from 214 EMPIAR datasets together with simulated projections from 268,000 molecular assemblies. EMber improves upon existing methods at conformational and compositional discrimination by 14.85 and 14.26 percentage points, estimates conformational populations to within 1.59pp error with a linear probe, and produces particle assignments yielding reference-quality reconstructions in fewer epochs. We demonstrate how to learn representations that capture biological information for use across multiple cryo-EM inverse problems.
Nithin Chalapathi, Theo Sternlieb, Ethan Han +4
University of California, Berkeley · Flatiron Institute · University of Maryland, College Park
Reconstructing protein structures from cryo-electron microscopy (cryo-EM) maps is essential for understanding macromolecular assemblies. Although learning-based methods have improved protein reconstruction, information from hetero components remains underused. Our analysis finds both false predictions and reference protein sites near hetero components; filtering nearby candidates can improve or impair chain construction. We introduce CryoCue, a framework that uses hetero information to guide protein reconstruction. An anchor-supervised detector learns hetero representations across five component classes. Multiscale hetero features guide backbone localization, while predicted hetero candidates condition structure refinement through their class, confidence, and frame-relative geometry. Experiments show that CryoCue improves backbone localization near hetero components and achieves more accurate protein structure reconstruction.
Xu Han, Chaozhuo Li, Xiaowei Yuan +3
University of Chinese Academy of Sciences, Beijing, China · Key Laboratory of Complex Systems Cognition and Decision, Institute of Automation, Chinese Academy of Sciences, Beijing, China · Beijing Academy of Artificial Intelligence, Beijing, China +2