As dwellings electrify and more complex electricity pricing spreads in Belgium, the question arises: What are the potential benefits of installing an advanced energy management systems in an electrified Belgian dwelling ? To answer this question, we simulate 500 representative Belgian dwellings in which fossil systems are replaced by controllable electric technologies: space heating via air-to-air heat pumps, domestic hot water via electric boilers, and private transport via electric vehicles with home chargers. Photovoltaic systems are assigned according to current adoption rates. We evaluate two advanced energy management systems (EMS): model predictive control (MPC) and TreeC, a machine learning method using decision trees to model the EMS strategy. These are compared to a rule-based controller (RBC) that mimics default operation and an MPC with perfect forecasts (MPC P) as an upper bound. Performance for these EMSs is assessed for 2023 under a real contract with hourly prices and a monthly peak tariff. Average annual savings versus RBC are 82.5 EUR, 116.6 EUR, and 177.4 EUR for TreeC, MPC, and MPC P, respectively. All EMSs deliver similar thermal comfort (26-31 Kh). MPC saves more, while TreeC achieves higher EV charge completion (93.3% vs 88.8% for MPC, with a max charge of 95%) and a smoother aggregate load across the 500 dwellings. Savings remain modest relative to EMS purchase (280-680 EUR) and subscription (0-360 EUR/year) costs which is not favourable towards widespread adoption. The data and code to reproduce this study are available at https://github.com/EVERGi/should_belgians_install_advanced_ems_paper.
Figures & tables
Figure 1. 1 Rue de la Paix, Ville-Basse, Charleroi, Belgium ( Jmh2o, 2020 ) . A residential street in Charleroi, Belgium, showing a mix of dwellings.
Figure 2. Flow chart of this study’s methodology to simulate a dwelling. Blue nodes represent the sampled characteristics of the dwelling with associated tables and sources (section A.1 ), orange nodes represent the data and simulation models used for each part of the dwelling ( sections A.2 , A.6 , A.4 , A.5 and A.3 ), green nodes represent the possible control actions of the assets ( section 3 ), and the red node is the dwelling simulation that combines everything together. Flow chart illustrating the methodology for simulating a dwelling. The chart is divided into four main sections: dwelling characteristics (blue nodes), data and simulation models (orange nodes), asset management (green nodes), and the dwelling simulation (red node). Each section contains specific components, such as region, PV, garage, central heating, construction type, insulation level, number of rooms, surface area, number of bedrooms, electric consumption profile, PV profile, EV and charger profile, thermal and heat pump model, domestic hot water model, and control actions for EV charger, heat pump, and water heater. Arrows indicate the flow of information and connections between these components, demonstrating how they interact to create a comprehensive dwelling simulation.
Figure 3. Illustration of the comfort temperature ranges for sleeping and home occupancy profiles as a function of the reference external temperature Tde,ref . The plot covers Tde,ref values from −9∘ C to 28∘ C, representing the coldest and warmest reference temperatures observed in Belgium during the 21st century. A line graph showing the comfort temperature ranges for sleeping and home occupancy profiles as a function of the reference external temperature T {e,ref} d. The x-axis represents the reference external temperature ranging from -9°C to 28°C, while the y-axis represents the comfort temperature in °C. Two lines are plotted: one for sleeping comfort range and another for home occupancy comfort range. The sleeping comfort range is lower than the home occupancy comfort range across all reference external temperatures.
Figure 4. Decision trees for each controllable asset in the TreeC EMS for dwelling 1. Four decision trees showing the control strategies for each controllable asset in dwelling 1. Each tree has nodes representing conditions based on features such as outdoor temperature, day-ahead price, occupancy profile, and tank temperature. The leaves of the trees indicate the setpoints for heating, cooling, EV charger power, and water heater power.
Figure 5. Illustration of the operation of the different EMSs over the weekend of 18-19 March 2023 for dwelling 1. The top four plots show the stacked power consumption and production of each asset, with the total grid connection power indicated in black. The four lower plots show the day-ahead electricity prices, the state of charge of the connected EV, the water heater’s tank temperature, and the indoor temperature for each EMS. Eight plots showing the operation of different EMSs over a weekend for dwelling 1. The top four plots display the power consumption and production of each asset, with the total grid connection power indicated in black. The four lower plots illustrate the day-ahead electricity prices, the state of charge of the connected EV, the water heater's tank temperature, and the indoor temperature for each EMS. The RBC EMS charges the EV at maximum power, while TreeC charges at a lower power to avoid peaks but still ensures full charge. MPC fails to fully charge the EV due to incorrect forecasting, while MPC P effectively utilizes excess PV production and low prices for charging. The water heater and heating strategies vary among EMSs based on electricity prices and PV production.
Figure 6. Comparison of key performance metrics for the different EMSs: (a) total yearly cost, (b) difference in electricity cost with the RBC EMS, (c) thermal discomfort, and (d) mean departure state of charge for EV charging sessions. For each EMS, violin plots (a) and (b) include 500 dwellings, (c) includes the 447 dwellings with a heat pump, and (d) includes the 344 dwellings with an EV charger. Each violin plot shows the distribution of results across all dwellings. The width of the violin at each value reflects the relative frequency of dwellings with that result. The horizontal dashes within each violin indicate the minimum, mean, and maximum values for each EMS. Four violin plots comparing key performance metrics for different EMSs across multiple dwellings. The first plot shows the total yearly cost, indicating a hierarchy in performance with RBC having the highest costs and MPC P the lowest. The second plot illustrates the difference in electricity cost compared to RBC, showing significant cost reductions for TreeC, MPC, and MPC P. The third plot presents thermal discomfort levels, with all EMSs achieving similar mean discomfort levels but TreeC maintaining lower maximum discomfort. The fourth plot displays the mean departure state of charge for EV charging sessions, highlighting that TreeC outperforms MPC in ensuring higher charge levels at departure. Each plot includes horizontal dashes indicating minimum, mean, and maximum values for each EMS.
Figure 7. Comparison of EMS performance for different dwelling features: (a) PV presence, (b) EV charger presence, (c) insulation level, and (d) water heater’s tank volume Five subplots comparing EMS performance based on different dwelling features. Each subplot presents violin plots showing the distribution of cost savings relative to the RBC EMS for each feature category. The features analyzed include the presence of PV systems, EV chargers, insulation levels, water heater tank volumes, and the number of assets in the dwelling. Each violin plot illustrates the variability in EMS performance across dwellings with the specified feature, with horizontal dashes indicating minimum, mean, and maximum values for each EMS.
Figure 8. Breakdown of cost savings relative to the RBC EMS for each cost component defined in eq. 4 . Offtake extras costs improvement reflects better energy efficiency, day-ahead costs improvement reflects better hourly price optimization, and peak costs improvement reflects reductions in peak grid power. Each box plot summarizes the results across the 500 dwellings. Box plots breaking down cost savings relative to the RBC EMS for each cost component: offtake extras costs, day-ahead costs, and peak costs. Each box plot summarizes the distribution of cost savings across 500 dwellings for each EMS. The offtake extras costs improvement shows minimal savings, indicating limited gains in energy efficiency. The day-ahead costs improvement highlights significant savings achieved by MPC and MPC P, reflecting their superior hourly price optimization capabilities. The peak costs improvement indicates that TreeC slightly outperforms MPC in reducing peak grid power consumption. Each box plot includes horizontal lines representing the median, interquartile range, and potential outliers for each EMS.
Figure 9. Yearly mean of the total grid power consumption of the 500 dwellings for each time step of the day. Each EMS is represented as well as the mean day-ahead electricity prices ( Vdt ) for the year 2023. Line plot showing the yearly mean of total grid power consumption for 500 dwellings across different EMSs for each time step of the day. The plot includes lines for each EMS (RBC, TreeC, MPC, MPC P) and a line representing the mean day-ahead electricity prices for 2023. The x-axis represents the time of day in hours, while the y-axis indicates the total grid power consumption in kW. The plot illustrates how each EMS manages grid power consumption throughout the day in relation to electricity pricing.
Forecast method
Predicted value
MAE (Mean ± Std. dev.)
K-NN regression
Connection time
7h14min ± 4h33min
Repeat last
Connection time
9h14min ± 5h7min
K-NN regression
SOC demand
12.8% ± 3.4%
Repeat last
SOC demand
16.4% ± 5.4%
Table 1. Mean absolute error (MAE) of two forecasts for the EV charging sessions. Values show the mean and standard deviation of MAE across all dwellings with an EV charger for 2023.
Appendix figures & tables13 assets
Supplementary material from the paper’s appendix.
Appendix
Brussels
Flanders
Wallonia
10.6%
57.4%
32.0%
Appendix
Table A.1 . Distribution of dwellings per region ( Statbel, 2021a )
Brussels
Flanders
Wallonia
Total
With central heating
10.1%
51.9%
27.4%
89.4%
Without central heating
0.5%
5.5%
4.6%
10.6%
Appendix
Table A.2 . Distribution of dwellings with central heating ( Statbel, 2021a )
Brussels
Flanders
Wallonia
Total
1 room
0.3%
0.5%
0.4%
1.2%
2 rooms
0.8%
1.6%
1.0%
3.4%
3 rooms
2.1%
4.6%
2.5%
9.2%
4 rooms
3.2%
10.0%
5.1%
18.3%
5 rooms
1.8%
14.0%
7.4%
23.2%
6 rooms
0.9%
12.6%
7.1%
20.6%
Appendix
Table A.3 . Distribution of dwellings per number of rooms ( Statbel, 2021b )
Number of rooms
1
2
3
4
5
6
7
8
9+
Total
0 bedroom
0.4%
1.2%
2.5%
2.5%
2.0%
0.3%
-
-
-
8.9%
1 bedroom
0.8%
2.2%
5.6%
5.6%
4.6%
1.2%
-
-
-
20.0%
2 bedrooms
-
-
1.1%
8.2%
12.3%
10.3%
5.1%
2.1%
2.0%
41.1%
3 bedrooms
-
-
-
2.0%
4.0%
6.5%
5.1%
2.2%
2.1%
21.9%
4 bedrooms
-
-
-
-
0.3%
2.2%
1.4%
1.3%
1.0%
6.2%
5 bedrooms
-
-
-
-
-
0.1%
0.3%
0.6%
0.5%
1.5%
Appendix
Table A.4 . Distribution of dwellings per number of bedrooms ( Meireles et al., 2022 )
Number of rooms
1
2
3
4
5
6
7
8
9+
Total
<35m²
1.1%
1.7%
0.9%
-
-
-
-
-
-
3.7%
35-54m²
0.1%
1.0%
2.8%
5.5%
4.6%
3.1%
-
-
-
17.1%
55-84m²
-
0.7%
3.7%
7.3%
7.0%
5.1%
1.2%
-
-
25.0%
85-104m²
-
-
1.8%
3.7%
7.0%
6.2%
3.6%
0.5%
0.5%
23.3%
105-124m²
-
-
-
1.8%
2.3%
4.1%
3.6%
1.6%
1.5%
14.9%
>124m²
-
-
-
-
2.3%
2.1%
3.5%
4.2%
3.9%
16.0%
Appendix
Table A.5 . Distribution of dwellings per surface area ( Vanneste et al., 2007 )
Brussels
Flanders
Wallonia
Total
With garage and car
3.8%
42.7%
22.4%
68.9%
Without garage or car
6.8%
14.7%
9.6%
31.1%
Appendix
Table A.6 . Distribution of dwellings with a garage and a car ( Hubert and Toint, 2003 )
Brussels
Flanders
Wallonia
Total
With PV
0.2%
19.2%
6.4%
25.8%
Without PV
10.4%
38.2%
25.6%
74.2%
Appendix
Table A.7 . Distribution of dwellings with PV installation ( Brugel, 2024 ; Vlaams Energie- en Klimaatagentschap, 2024 ; Lallemand, 2023 )
Brussels
Flanders
Wallonia
Total
Terraced house
1.3%
11.7%
8.4%
21.4%
Semi-detached house
0.2%
10.6%
5.2%
16.0%
Detached house
0.1%
18.6%
10.1%
28.8%
Apartment unit
9.0%
16.5%
8.3%
33.8%
Appendix
Table A.8 . Distribution of dwellings per construction type ( Vanneste et al., 2007 )
Brussels
Flanders
Wallonia
Total
No insulation
1.3%
7.8%
11.5%
20.6%
Roof
5.6%
16.5%
15.5%
37.6%
Wall and roof
-
10.7%
0.2%
10.9%
Ground and roof
0.1%
-
-
0.1%
Ground, wall and roof
3.6%
22.4%
4.8%
30.8%
Appendix
Table A.9 . Distribution of dwellings by insulation level ( Recticel Insulation, 2020 )
Insulation level
Window U-value
Air tightness
No insulation
5.8 W/m²K
9.3 ACH 50
Roof
2.8 W/m²K
5.5 ACH 50
Double insulation
2.8 W/m²K
2.9 ACH 50
Ground, wall and roof
0.6 W/m²K
1.4 ACH 50
Appendix
Table A.10 . Window U-values and air tightness values
Figure A.1 . Probability density function of the estimated average daily hot water consumption per number of bedrooms in a dwelling. The mean value of the distribution is indicated by the vertical dashed line. Probability density function of the estimated average daily hot water consumption per number of bedrooms in a dwelling. The mean value of the distribution is indicated by the vertical dashed line.
Statistic
Mean
Std. dev.
Total energy charged per profile per year
2 414 kWh
1 464 kWh
Number of sessions in a year per profile
193.6
131.2
Session duration across all profiles
12h16min
11h12min
Session SOC charged across all profiles
31.7%
20.0%
Std. dev. of session duration per profile
9h46min
5h32min
Std. dev. of session SOC charged per profile
17.3%
2.6%
Appendix
Table A.11 . Summary statistics of the 16 EV charging profiles used in this study.
Year
Mean
Std. dev.
Min
Max
2020
0.032
0.017
-0.115
0.200
2021
0.104
0.079
-0.070
0.620
2022
0.245
0.135
-0.100
0.871
2023
0.097
0.046
-0.120
0.330
2024
0.070
0.0430
-0.140
0.566
2025
0.085
0.0482
-0.462
0.518
Appendix
Table A.12 . Electricity prices for the Belgian day-ahead market for years 2020 to 2025. All values are in €/kWh ( ENTSO-E, 2025 ) .
Building Energy Management coordinates HVAC, storage, and flexible loads to reduce energy use and emissions while maintaining comfort and reliable service.
Department of Data Science and AI, Faculty of Information Technology, Monash University, Melbourne, Victoria, Australia · Monash Energy Institute, Monash University, Melbourne, Victoria, Australia