cs.CLNov 19, 2026

Multimodal Error Detection in Chest X-ray Reports: A Large Language Model Reading Image Evidence

Authors: Yanda Cheng, Bo Wen, Yuhao Lu

Organizations: Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA · Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY, USA · School of Electrical and Computer Engineering, Cornell University, Ithaca, NY, USA

Abstract

Rad-Linter checks chest X-ray reports against image-derived evidence to flag potential errors for review. A pretrained image classifier supplies scores for nine pathologies, and a 1.5B-parameter language model, fine-tuned with LoRA on 1,816 examples, checks their consistency with the report. We compare it with a keyword-and-negation rule baseline given the same reports and scores. Evaluation uses controlled report-score pairings from OpenI, with consistency labels derived from automatic report labels and score thresholds. Each counterfactual quad crosses two real reports with two real score vectors from other patients, creating two consistent and two inconsistent pairs. Every report and score vector occurs in both conditions, so either input alone permits only 50% accuracy. On 131 quads, Rad-Linter achieves 98.5% pair accuracy versus 80.5% for the rule baseline, and classifies all four pairs correctly in 94.4% of quads versus 56.5%. The checkers perform similarly on omission items, including unmentioned and negated findings; larger differences occur on the remaining item types, which require interpreting how findings are described. The same language model without fine-tuning remains near 50% accuracy. On a second set of 181 quads that also includes reports on which the automatic labelers disagree, pair accuracy is 93.4% versus 75.3%. These controlled results show that, given the same image-derived scores, a trained language model detects report-score inconsistencies more accurately than the tested rule baseline, with the advantage concentrated in interpreting how findings are worded.

Figures & tables

Appendix figures & tables5 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jun 16, 2026

Vision-language models for chest radiography do not always need the image

Vision-language models that answer questions about chest radiographs are evaluated by their accuracy on labels derived from radiology reports. High benchmark accuracy is often interpreted as evidence that the model uses the image. A model that answers from the finding named in the question can score as well as a model that uses the radiograph. Keeping the question fixed, we audit eight open-weight systems by swapping in another patient's radiograph with the same or the opposite label, occluding the radiologist-marked region or an equal region elsewhere, and removing the radiograph or replacing it with noise or a photograph. On 2,548 yes-or-no questions from MIMIC-CXR, one multimodal model answers Yes regardless of the image, another multimodal model changes its answers without following the label, and four systems use the image but keep about half of their correct answers when the radiograph is swapped for an opposite-label radiograph. A medical model that receives only the question text scores 55.3% on the pooled questions, higher than two multimodal systems. It scores 91.8% where every finding is present, and answering Yes to every question scores 100% there. Where the image is necessary, the best multimodal system exceeds this model by 10.4% in balanced accuracy. The categories are unchanged on CheXpert. Confidence is not higher when a correct answer depends on the marked region. In a reader study with three radiologists, the two radiologists who read a balanced set of 200 cases score 86.0% and 82.0%, and the systems score 50.0% to 73.0%. Accuracy does not establish image use, but an intervention on the image can test it.
Mar 24, 2026

Ran Score: a LLM-based Evaluation Score for Radiology Report Generation

Chest X-ray report generation and automated evaluation are limited by poor recognition of low-prevalence abnormalities and inadequate handling of clinically important language, including negation and ambiguity. We develop a clinician-guided framework combining human expertise and large language models for multi-label finding extraction from free-text chest X-ray reports and use it to define Ran Score, a finding-level metric for report evaluation. Using three non-overlapping MIMIC-CXR-EN cohorts from a public chest X-ray dataset and an independent ChestX-CN validation cohort, we optimize prompts, establish radiologist-derived reference labels and evaluate report generation models. The optimized framework improves the macro-averaged score from 0.753 to 0.956 on the MIMIC-CXR-EN development cohort, exceeds the CheXbert benchmark by 15.7 percentage points on directly comparable labels, and shows robust generalization on the ChestX-CN validation cohort. Here we show that clinician-guided prompt optimization improves agreement with a radiologist-derived reference standard and that Ran Score enables finding-level evaluation of report fidelity, particularly for low-prevalence abnormalities.
Jul 7, 2026

Harrison.Rad 1.5 Technical Report: A radiology foundation model that can draft reports from images, priors and clinical context

Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone. The most direct opportunity is reducing the time and effort radiologists spend producing reports, a task that requires interpreting images, integrating clinical history and prior studies, and drafting structured findings. We present Harrison.Rad 1.5 (HR1.5), a radiology-specific multimodal large language model that accepts interleaved text and visual inputs and generates structured and unstructured text across plain-film radiology, spanning computed radiography, chest, musculoskeletal, abdominal, spine, and pelvic x-rays, and mammography. HR1.5 is trained through a three-stage pipeline: domain adaptation of a base language model on radiology reports, contrastive vision-encoder training with curriculum-based hard negatives on ~6 million image-report instances, and visual-question-answering fine-tuning on multi-turn conversations. We evaluate it with a Findings-Diagnosis scoring framework that extends RadGraph-XL entity extraction with ontology-based synonym matching and polarity-contradiction detection, benchmarked on RadBench, a simulated FRCR 2B Short Case examination scored against Angoff-method thresholds, ReXGradient, and internal multi-modality datasets. HR1.5 is the only system evaluated to meet the simulated FRCR passing standard and achieves the highest accuracy on closed-format clinical questions, across anatomical regions, on internal multi-body-part and mammography reporting, and on the primary clinically-aligned score for public chest reporting. We further examine explainability and model behaviour, including question-sensitive Grad-CAM heatmaps, attention analysis, and confidence estimation, to support responsible future evaluation toward clinical use, and a framework for clinically grounded assessment of report quality.