cs.AIMar 24, 2026

Ran Score: a LLM-based Evaluation Score for Radiology Report Generation

Authors: Ran Zhang, Yucong Lin, Zhaoli Su, Bowen Liu, Danni Ai, Tianyu Fu, Deqiang Xiao, Jingfan Fan, 

Organizations: School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China · Zhengzhou Research Institute, Beijing Institute of Technology, Zhengzhou 450003, China · School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China · Department of Radiology, China-Japan Friendship Hospital (Institute of Clinical Medical Sciences), Beijing 100029, China · 

Abstract

Chest X-ray report generation and automated evaluation are limited by poor recognition of low-prevalence abnormalities and inadequate handling of clinically important language, including negation and ambiguity. We develop a clinician-guided framework combining human expertise and large language models for multi-label finding extraction from free-text chest X-ray reports and use it to define Ran Score, a finding-level metric for report evaluation. Using three non-overlapping MIMIC-CXR-EN cohorts from a public chest X-ray dataset and an independent ChestX-CN validation cohort, we optimize prompts, establish radiologist-derived reference labels and evaluate report generation models. The optimized framework improves the macro-averaged score from 0.753 to 0.956 on the MIMIC-CXR-EN development cohort, exceeds the CheXbert benchmark by 15.7 percentage points on directly comparable labels, and shows robust generalization on the ChestX-CN validation cohort. Here we show that clinician-guided prompt optimization improves agreement with a radiologist-derived reference standard and that Ran Score enables finding-level evaluation of report fidelity, particularly for low-prevalence abnormalities.

Figures & tables

Explore similar work

Mar 6, 2026

CRIMSON: A Clinically-Grounded LLM-Based Metric for Generative Radiology Report Evaluation

We introduce CRIMSON, a clinically grounded evaluation framework for chest X-ray report generation that assesses reports based on diagnostic correctness, contextual relevance, and patient safety. Unlike prior metrics, CRIMSON incorporates full clinical context, including patient age, indication, and guideline-based decision rules, and prevents normal or clinically insignificant findings from exerting disproportionate influence on the overall score. The framework categorizes errors into a comprehensive taxonomy covering false findings, missing findings, and eight attribute-level errors (e.g., location, severity, measurement, and diagnostic overinterpretation). Each finding is assigned a clinical significance level (urgent, actionable non-urgent, non-actionable, or expected/benign), based on a guideline developed in collaboration with attending cardiothoracic radiologists, enabling severity-aware weighting that prioritizes clinically consequential mistakes over benign discrepancies. CRIMSON is validated through strong alignment with clinically significant error counts annotated by six board-certified radiologists in ReXVal (Kendalls tau = 0.61-0.71; Pearsons r = 0.71-0.84), and through two additional benchmarks that we introduce. In RadJudge, a targeted suite of clinically challenging pass-fail scenarios, CRIMSON shows consistent agreement with expert judgment. In RadPref, a larger radiologist preference benchmark of over 100 pairwise cases with structured error categorization, severity modeling, and 1-5 overall quality ratings from three cardiothoracic radiologists, CRIMSON achieves the strongest alignment with radiologist preferences. We release the metric, the evaluation benchmarks, RadJudge and RadPref, and a fine-tuned MedGemma model to enable reproducible evaluation of report generation, all available at https://github.com/rajpurkarlab/CRIMSON.
Apr 21, 2026

CXRMate-2: Structured Multimodal Temporal Embeddings and Tractable Reinforcement Learning for Clinically Acceptable Chest X-ray Radiology Report Generation

Chest X-ray (CXR) radiology report generation (RRG) models have shown rapid progress on automated metrics, yet their clinical utility remains uncertain due to limited qualitative evaluation by radiologists. We present CXRMate-2, a state-of-the-art CXR RRG model that enables tractable reinforcement learning (RL) through structured multimodal temporal embeddings and high-resolution visual feature compression, for efficient, unified conditioning of an LLM decoder on visual, textual, and temporal context from a study and its prior. This enables group relative policy optimisation (GRPO), where a proposed reward function is used to improve semantic alignment with radiologist reports. Across the MIMIC-CXR, CheXpert Plus, and ReXgradient datasets, CXRMate-2 achieves statistically significant improvements over strong benchmarks, including gains of 11.2% and 24.4% in GREEN and RadGraph-XL, respectively, on MIMIC-CXR relative to MedGemma 1.5 (4B). To directly compare CXRMate-2 against radiologist reporting, we conduct a blinded, randomised qualitative retrospective evaluation. Three consultant radiologists compare generated and radiologist reports across 120 studies from the MIMIC-CXR test set. Generated reports were deemed acceptable (defined as preferred or rated equally to radiologist reports) in 45% of ratings, with no statistically significant difference in preference rates for seven of the eight analysed findings. Preferences for radiologist reports were driven primarily by higher recall, while generated reports were consistently preferred for readability. Together, these results define a clear pathway to clinically acceptable CXR RRG. Improving recall and the detection of subtle findings represents the primary remaining barrier to non-inferiority with radiologist reporting, positioning CXR RRG for prospective evaluation in assistive, radiologist-led workflows.
Jul 21, 2026

DobicVLM: Aligning Chest X-Ray Report Generation with Clinically-Grounded Programmatic Rewards via Group Relative Policy Optimization

Medical imaging is a cornerstone of diagnostics, yet automated chest X-ray report generation struggles with structural adherence, anatomical completeness, and semantic faithfulness. We introduce DobicVLM, a vision-language model combining supervised fine-tuning on MedGemma-4B with Group Relative Policy Optimization (GRPO) and clinically-grounded programmatic rewards. Our approach uses interpretable, rule-based reward components; structural verification, anatomical checklist, semantic similarity, and length constraints to enforce clinical standards without neural reward models. Trained on 1,000 de-identified image-report pairs from a private clinical dataset (with ethics approval and compliance to local regulations), DobicVLM is evaluated via blinded expert review on 69 held-out cases. DobicVLM outperforms Gemini 2.5 Flash across the majority of criteria, achieving the highest impression accuracy (27.2%) and medical terminology (86.5%) compared to both Gemini 2.5 Flash and MedGemma 4B baselines, with minor trade-offs in completeness and referrals. This demonstrates GRPO's value for transparent alignment in resource-limited settings. Keywords: Vision-Language Models, Radiology Report Generation, Reinforcement Learning, Medical AI, GRPO