Abstract

Learning robotic ultrasound policies requires interactive environments for scalable data generation and repeatable evaluation, while exploration on real patients is limited by acquisition costs and safety constraints. Generative world models offer an alternative, but image history and probe actions alone do not ensure anatomical consistency across wide-range scans and changing acoustic windows. We introduce SonoAtlasWorld, an ultrasound world model built on anatomy as state. A persistent 3D anatomical asset extracted from computed tomography (CT) anchors each scan to a specific anatomy. Probe actions determine anatomical and acoustic visibility conditions for a causal ultrasound generator trained on clinical videos. Our three-stage pipeline combines anatomy-conditioned pretraining, causal conversion and long-rollout alignment. Inference optimizations achieve pose-to-ultrasound throughput of 81.2 FPS. To evaluate anatomical control beyond image similarity, we introduce the Action-Following Index (AFI), which measures normalized reconstruction gain over a static-prefix baseline. On 40 held-out 3D volumes, SonoAtlasWorld achieves liver and macro-organ AFI of 0.428 and 0.262, compared with at most 0.117 and 0.038 for the tested action- and geometry-conditioned methods. Long-rollout alignment reduces brightness drift by 3.46x at the end of 40 repeated scan cycles. SonoAtlasWorld also generates offline policy-training demonstrations and supports anatomically grounded closed-loop evaluation. Scaling the generated training data improves key-plane acquisition success from 48.2% to 81.2% on unseen anatomies in simulation, demonstrating its utility for robotic ultrasound policy learning.

Figures & tables

Explore similar work

Oct 14, 2026

SonoWorld: Towards Interactive Pose-Controllable Ultrasound World Models

Robotic ultrasound can standardize image acquisition and reduce operator workload and variability, but policy learning remains limited by the lack of realistic, controllable simulation environments. While controllable world models have advanced rapidly in natural-image domains, ultrasound world modeling remains challenging because each frame captures only a cross-section of unobserved 3D anatomy, causing small probe motions to induce large appearance changes. Existing approaches rely on robot-tracked poses and latent-space prediction, but do not directly generate the observations required for interactive control. We propose SonoWorld, a causal ultrasound world model that learns video dynamics from unlabeled clinical videos and grounds them to 6-DoF control using a small set of freehand clinical scans tracked with an EM sensor. SonoWorld is trained in three stages: pretraining a latent-action-conditioned video diffusion model on around 6.9 million unlabeled multi-organ ultrasound frames; grounding the learned video dynamics to metric probe poses with a small EM-tracked thyroid dataset; and applying distribution matching distillation to enable causal, long-horizon autoregressive generation with selectively caching eviction tokens at inference time. We evaluate controllability through pose-following fidelity, round-trip consistency, and axis-specific control under synthetic actions on held-out tracked scans, and further validate it with a user study. In model-based action discrimination, SonoWorld correctly ranks the target-directed probe motion over an equal-magnitude opposite motion in up to 74.8% of trials. To our knowledge, SonoWorld is the first causal, pose-controllable ultrasound world model learned primarily from freehand clinical videos, providing a data-driven interactive environment for robotic ultrasound data acquisition and policy evaluation.
Oct 7, 2026

UltraWorld: Learning Interactive Ultrasound World Models from Untracked Clinical Videos with Acoustic Sampling Map

World models can enable autonomous ultrasound scanning by predicting the outcomes of probe motions from local observations. Learning this action--observation relationship typically relies on synchronized video--pose pairs, which are costly to collect at scale and largely unavailable in routine clinical recordings. Reliable action following further requires modeling ultrasound's cross-sectional sampling geometry. We present UltraWorld, a self-distillation recipe that transfers priors from clinical ultrasound videos into interactive world models without real action annotations. Starting from clinical videos, we adapt a video foundation model into an ultrasound generator conditioned on reference images and anatomical masks. Anatomical masks sampled along programmable trajectories through 3D anatomy provide spatial guidance for synthesizing action--video pairs. We then use these synthetic pairs to self-distill the generator into a world model that predicts future observations from local observations and actions, without requiring anatomical masks or other 3D assets at inference time. To further improve action following, we introduce the Acoustic Sampling Map (AsMap), which represents probe poses and imaging settings as pixel-wise 3D sampling positions, beam directions, and depths. Experiments demonstrate improved prediction fidelity and action following. Across nine simulated closed-loop local planning episodes, UltraWorld reduces the mean final distance to the goal and orientation error by 29% and 38%, respectively, compared with visual servoing. Project Page: https://ultraworld-project.github.io/.
Jul 24, 2026

Action-Conditioned World Model for Goal Plane Guidance in Robotic Neck Ultrasound

Ultrasound examinations typically follow specific scanning protocols that require navigating through an ordered sequence of anatomical landmarks and target imaging planes. We present a local action-conditioned world model framework for goal plane probe guidance in robotic ultrasound. Autonomous ultrasound tasks often require large numbers of probe-motion trajectories for training, but collecting high-quality demonstrations is labor-intensive and explicit simulators are difficult to build because ultrasound appearance depends on contact, tissue deformation, and view-dependent acoustic artifacts. We address this problem with a two-stage model-based learning pipeline. First, a latent conditional diffusion world model predicts future ultrasound observations from recent context frames, probe motions and temporal offset. Second, a goal-conditioned temporal transformer predicts ordered probe motions and is fine-tuned using rewards from the frozen world model. Experiments on the self-collected dataset show that the world model preserves action-dependent anatomical structure on target-directed scans. In real-world closed loop experiments, the framework achieves success rates of 70.0% for carotid guidance and 65.0% for thyroid guidance. These results demonstrate the potential of learned ultrasound dynamics for training goal-directed robotic probe navigation within protocol-constrained organ specific tasks.