Feasibility of Multifrequency Neural Network-Based Wave Inversion in Ultrasound Time-Harmonic Elastography
Authors: Héloïse Bustin, Tom Meyer, Paul Spiesecke, Jakob Jordan, Anja Hennemuth, Ingolf Sack
Organizations: Deutsches Herzzentrum der Charité, Institute of Computer-assisted Cardiovascular Medicine, Augustenburger Platz 1, 13353 Berlin, Germany · Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany · Fraunhofer MEVIS, Berlin, Germany · DZHK (German Centre for Cardiovascular Research), Berlin, Germany
Ultrasound time-harmonic elastography (THE) is a non-invasive imaging technique that measures soft-tissue stiffness. Relying on the same principle of time-harmonic shear wave excitation as established magnetic resonance elastography (MRE), THE offers full field-of-view stiffness mapping at short acquisition times and sub-second temporal resolution across organs. However, reconstruction of shear wave speed maps from acquired tissue wavefields remains challenging due to speckle noise and sparse spatial coverage of the lateral component. Deep learning methods have shown promising results for image reconstruction in transient-based ultrasound elastography modalities but remain unexplored in THE. In MRE, MF-ElastoNet, a 2D multifrequency neural network-based wave reconstruction method trained on synthetic physics-based wave data, has shown high generalizability across dynamic ranges and resolutions. We investigated the potential of a multifrequency neural network-based wave inversion for THE, by performing a first feasibility analysis. To this end, we adapted the processing pipeline of MF-ElastoNet from MRE to THE. We tested our approach on THE acquired phantom data from the algorithms for mapping elastic modulus Challenge, as well as on in vivo liver THE in 4 healthy volunteers and 14 patients with focal liver lesions, including benign focal nodular hyperplasia, and malignant hepatocellular carcinoma and adenocarcinoma. MF-ElastoNet was successfully adapted to THE with in vivo liver testing. Compared with k-MDEV, the state-of-the-art wave inversion method for THE, Bland-Altman analysis showed a mean bias of -0.02 m/s (95% limits of agreement: -0.36 to 0.33 m/s).
Figures & tables
Figure 1: Wave inversion processing pipeline: A) Multifrequency complex-valued wavefields were smoothed. 12 × 12 patches were then extracted from the images and downsampled to 4 × 4. B) Multifrequency 4 × 4 complex-valued patches were processed by MF-ElastoNet, obtaining multifrequency SWS (shear wave speed) and quantifying the associated prediction uncertainty via the CV (coefficient of variation). C) Processed SWS values and associated uncertainty were mapped to frequency-resolved SWS and CV maps. These were averaged to obtain the final SWS and CV maps.
Figure 2: Wavefields, SWS (shear wave speed), and CV (coefficient of variation) maps predicted by MF-ElastoNet for phantoms I, II, and III as well as their respective ROIs (regions of interest) as a white dashed line.
Phantom
Metric
k-MDEV
MF-ElastoNet
Phantom I
SWS std. (m/s)
0.083
0.178
Phantom II
CNR
2.87
1.57
Edge width (mm)
8.16
3.66
Edge accuracy (mm)
-2.37
1.25
Phantom III
CNR
2.09
2.69
Edge width (mm)
2.93
6.55
Table 1: aMEM Challenge metrics for k-MDEV and MF-ElastoNet: For phantom I, the spatial variation of the SWS (shear wave speed) is reported through the standard deviation (std.). For phantoms II and III, the CNR (contrast-to-noise ratio), edge sharpness through the edge width, and the edge accuracy are reported.
Figure 3: B-mode, wavefield, SWS (shear wave speed) maps produced by k-MDEV and MF-ElastoNet, and CV (coefficient of variation) maps predicted by MF-ElastoNet are reported for two healthy volunteers, and three patients, including benign (23-year-old female with focal nodular hyperplasia) and malignant (81-year-old female with hepatocellular carcinoma and 49-year-old male with metastatic colorectal adenocarcinoma) cases. Liver parenchyma (white) and tumor (magenta) are additionally shown overlaid on all images.
Figure 4: Bland-Altman analysis of SWS (shear wave speed) values: MF-ElastoNet vs k-MDEV. Color denotes the subject groups (green: healthy volunteer, blue: focal nodular hyperplasia (FNH), purple: hepatocellular carcinoma (HCC), brown: adenocarcinoma), and marker shape tissue type (circle: liver parenchyma; cross: tumor).
Ultrasound imaging uses sound waves to visualize anatomy and function, with AI improving image reconstruction, diagnosis, measurement, and scan guidance.
Objective: Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique for mapping biomechanical properties of in vivo tissue, including shear wave speed (SWS), but involves intrinsically slow data acquisition and an ill-posed wave inversion. Instead of relying on handcrafted image priors, we propose a data-driven approach jointly combining image reconstruction and MRE inversion for robust SWS estimation from undersampled k-space data. Methods: Our physics-informed reconstruction framework comprises two blocks: a model-based neural network (NN)-regularized reconstruction module and a phase-gradient inversion (k-MDEV) calculating SWS from the reconstructed images. Concatenating both blocks yields an end-to-end trainable method to estimate SWS directly from measured k-space data. We evaluated the method on retrospectively highly undersampled brain MRE data and compared it to a total variation (TV) minimization-based approach. We assessed the impact of end-to-end training (qualitative images and SWS maps as targets) versus pre-training (qualitative images as targets) and applied the method also to in vivo data. Results: Our approach significantly reduces NRMSE by 30% compared to TV. End-to-end training improves SWS estimation over separate image reconstruction and SWS calculation. Conclusion: Accurate SWS quantification is possible at acceleration factors up to 19. Our method significantly outperforms TV, highlighting the need for data-driven regularization in this challenging MR problem. Further, our approach successfully generalizes to in vivo data. Significance: We present the first end-to-end trainable MRE reconstruction method for estimating SWS maps directly from k-space. NN-based reconstruction can enable rapid stiffness mapping for dynamic studies, functional imaging, and real-time clinical feedback.
Stefan Martin, Jakob Schattenfroh, Patrick Schuenke +4
To develop a deep-learning method for achieving fast high-resolution MR elastography from highly undersampled data without the need of high-quality training dataset. We first framed the deep neural network representation as a nonlinear extension of the linear subspace model, then used it to represent and reconstruct MRE image repetitions from undersampled k-space data. The network weights were learned using a multi-level k-space consistent loss. To further enhance reconstruction quality, phase-contrast specific magnitude and phase priors were incorporated, including the similarity of anatomical structures and smoothness of wave-induced harmonic displacement. Experiments were conducted using both 3D gradient-echo spiral and multi-slice spin-echo spiral MRE datasets. Compared to the conventional linear subspace-based approaches, the nonlinear network representation method was able to produce superior image reconstruction with suppressed noise and artifacts from a single in-plane spiral arm per MRE repetition (e.g., 2mm isotropic resolution in 1 min with a total R=10), yielding comparable stiffness estimation to the fully sampled data. This work demonstrated the feasibility of using deep network representations to model and reconstruct MRE images from highly-undersampled data, a nonlinear extension of the subspace-based approaches.
Xi Peng
Departments of Radiology, Biomedical Engineering, Electronic and Computer Engineering, and Mechanical Engineering, University of Iowa, Iowa City, IA 52246 · Department of Radiology, University of Iowa, Iowa City, IA, 52246
Magnetic resonance elastography (MRE) is a noninvasive imaging modality for quantifying the viscoelastic properties of soft tissues from shear wave propagation. Recovering the complex-valued shear modulus from measured displacement fields leads to a severely ill-posed inverse problem, particularly in the presence of noise and limited boundary excitations. We investigate adjoint-based optimization, convolutional neural network (CNN) reconstruction, and a hybrid framework combining both approaches. The forward model is based on a scalar form of the modified stationary Stokes system with a complex shear modulus. We establish well-posedness of the forward problem, existence of minimizers, and first-order optimality conditions for the adjoint-based formulation, and implement a nonlinear conjugate-gradient method with Armijo line search. While PDE-constrained optimization can accurately refine coefficient reconstructions, its performance depends strongly on initialization. We therefore construct a two-dimensional CNN that maps complex-valued displacement measurements to spatially varying complex shear modulus fields and provides rapid, informative initial reconstructions. The proposed hybrid method uses the CNN reconstruction to initialize the adjoint-based optimization, yielding faster convergence and improved accuracy. The CNN is trained on coefficient fields containing individual perturbations and tested on both individual and previously unseen combined configurations. Numerical experiments demonstrate that the CNN generalizes to these more challenging configurations, while subsequent PDE-constrained optimization further refines the reconstructed coefficient. These results demonstrate the potential of combining data-driven initialization with physics-based optimization for efficient and accurate MRE reconstruction.
Anwesa Dey, Johann Rudi, Elena Cherkaev
Department of Mathematics, The University of Utah, address USA. · Department of Mathematics, Virginia Tech, address USA. · Department of Mathematics, The University of Utah, address, address, USA.