eSPG: The Unreasonable Effectiveness of Event Speckle Plethysmography
Authors: Aniket Dashpute, Anirudh Bindiganavale Harish, Bhargav Ghanekar, Alankar Kotwal, Andrew Negrut, Syna Gupta, Pablo A. Valdes, Ashok Veeraraghavan
Organizations: Department of Electrical and Computer Engineering, Rice University, Houston, Texas, USA · Department of Neurosurgery, University of Texas Medical Branch, Galveston, Texas, USA
Non-contact measurement of vital signs such as heart rate (HR) is valuable for patient monitoring and rescue operations. However, existing methods struggle with ambient illumination and motion, and have been demonstrated only at distances of tens of meters. Here we introduce event speckle plethysmography (eSPG), which illuminates a body part with a low-power (0.5-5 mW) laser and captures the resulting dynamic speckle pattern using an event camera. Event cameras, with their high dynamic range, temporal resolution, and sensitivity to intensity changes, are well-suited to capturing rapid speckle fluctuations that encode the physiological signal, even under challenging illumination and imaging conditions. We demonstrate HR estimation at 1 km with a mean absolute error of 5 beats per minute, and 90% of estimates satisfy an AAMI-defined HR estimation criterion. This distance exceeds previous remote plethysmography demonstrations by an order of magnitude and previous speckle plethysmography demonstrations by over three orders of magnitude. We also study and characterize robustness to motion and ambient illumination. Our theoretical analysis and experimental results demonstrate that resolving dynamic speckle fluctuations enables accurate heart rate estimation even at kilometer-scale distances, establishing a new direction toward robust, non-contact physiological monitoring.
Figures & tables
Figure 1: Our approach uses laser illumination and an event camera to image speckle dynamics for plethysmography, enabling heart rate estimation at 1 km imaging distance. a, Across all experiments, our setup comprises a laser and an event camera for capturing speckle patterns. b, Long-distance measurements use telescope optics with an event camera, while the laser illuminates from 60 to 100 m distance. c, The estimated eSPG signal is effective even at distances of 1\penaltykm , an order of magnitude greater than state-of-the-art works across different methods (papers from the plot: [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 ] ; papers marked with arrows do not report heart rate estimation errors). d, When the beamwidth is narrow (e.g., in cases of short-distance illumination), a larger volume of blood from arterial dilation increases scattering, limiting the depth of light penetration, thus reducing the radial spread of the events. e, When the beamwidth is larger (e.g., in cases of long-distance illumination), the main indicator of pulsing is observed in changes in event rate, primarily due to changes in blood flow speed.
Figure 2: eSPG signals can be imaged with high fidelity even at long imaging distances ( 350\penaltym,750\penaltym,1\penaltykm ). a, Our experimental setup consists of a camera (event camera for eSPG or frame camera for iSPG) mounted on a telescope on the 10th floor of a building. Here, we illustrate the relative scale of the participant in the car with respect to the imaging distance - 350\penaltym in this case. The participant is seated in a car, and the event camera and frame-based camera are alternated after each recording. The laser (operated at 4.99 mW) is placed ≈60\penaltym from the participant, ensuring adequate beam coverage of the hand without significant power loss from its divergence. We capture measurements at three distances: b 350\penaltym , c, 750\penaltym , and d, 1\penaltykm . Across all three distances, the periodic nature of the plethysmography signals is captured with high fidelity. While SNR degrades at greater distances, the dominant frequency peak is still discernible at 1\penaltykm .
HR Error ( BPM )
Clinical
Method
MAE ↓
RMSE ↓
MAPE(%) ↓
r↑
AAMI ↑
350\penaltym
distPPG
52.2±4.7
56.3±20.3
63.0±6.3
0.24±0.23
1/20
iSPG
3.4±1.7
8.5±7.8
4.1±2.1
0.65±0.18
18/20
iSPG++ (ours)
1.8±0.6
3.2±2.4
2.2±0.7
0.93±0.09
18/20
eSPG (ours)
3.6±2.2
10.4±9.5
4.3±2.6
0.32±0.22
18/20
750\penaltym
distPPG
24.7±3.1
28.3±12.9
29.4±3.7
−0.42±0.21
4/20
Table 1: Long-range: eSPG shows consistently high performance across across 3 long-range imaging distances ( 350\penaltym,750\penaltym,1\penaltykm ). For each of the three imaging distances, the data were collected by illuminating the palms of 5 participants, with 4 measurements per participant (two samples from each hand). As the imaging distances increase, the performance of the intensity-based methods degrades. This is particularly evident in the simultaneous rise in MAE and the drop in AAMI clinical threshold score. On the other hand, the event-based method is more stable, as evidenced by a consistent MAE and AAMI score across the 3 imaging distances.
Figure 3: eSPG reliably captures HR at 100\penaltym laser and camera distance and is robust to motion and extreme illumination at shorter distances ( <1\penaltym ). a, The participant is imaged 100\penaltym from the laser-camera setup. The cameras are alternated between trials, and the ground-truth signals are captured using a pulse oximeter on the participant’s hand. b, eSPG signals are faithfully estimated from the participants for the 100\penaltym setup. c, For the short-range ( <1\penaltym ) measurements, both cameras and the laser are mounted together as a single stack, and recordings are captured under various operating conditions: motion, varied laser profiles, and extreme ambient illumination. d, At such short distances, we see the faithful capture of higher-order harmonics, especially when the hand is kept stationary. A stratified analysis of the various imaging conditions is presented in Table 3 .
HR Error ( BPM )
Clinical
Method
MAE ↓
RMSE ↓
MAPE(%) ↓
r↑
AAMI ↑
distPPG
68.8±3.0
70.1±20.6
90.3±7.8
0.02±0.24
0/20
iSPG
4.1±1.7
8.6±7.5
5.8±2.8
0.77±0.15
17/20
iSPG++ (ours)
2.0±0.6
3.5±2.5
2.5±0.8
0.97±0.06
19/20
eSPG (ours)
1.1±0.2
1.4±0.8
1.3±0.2
1.00±0.02
20/20
Table 2: All SPG methods, particularly eSPG, show promising performance on mid-range imaging, i.e., imaging and illumination distances at 100\penaltym . The data was collected by illuminating the palms of 5 participants, with 4 measurements per participant (two samples from each hand). Across all samples, the event-based method outperforms all intensity baselines, with eSPG estimates passing the AAMI clinical threshold for all 20 samples.
HR Error ( BPM )
Clinical
Method
MAE ↓
RMSE ↓
MAPE(%) ↓
r↑
AAMI ↑
Still
distPPG
24.6±4.9
29.0±17.7
37.7±9.0
−0.20±0.35
1/10
iSPG
0.7±0.5
1.8±1.8
0.9±0.6
0.99±0.05
10/10
iSPG++ (ours)
3.9±3.0
10.4±10.0
5.3±4.2
0.71±0.25
9/10
eSPG (ours)
0.7±0.5
1.8±1.8
1.0±0.6
0.99±0.05
10/10
Hand Motion
distPPG
22.8±4.3
30.0±16.6
30.8±5.8
−0.10±0.23
4/20
Table 3: eSPG demonstrates robustness to external factors such as corruption from motion, ambient illumination, and changes to the laser power and beam profile. The still case is the baseline reading where the participant remains stationary. On more complex tasks, such as hand motion and extreme ambient light , eSPG outperforms all frame-based methods. Further, eSPG is not sensitive to the choice of laser illumination, with our method yielding low error for sub- mW lasers and for HeNe lasers with Gaussian and uniform beam profiles. However, our method is not robust to the laser’s motion. In this case, eSPG produces higher errors than its baselines, which is a limitation of our method.
Figure 4: eSPG can be computed from either event count or radial spread, and the selection can be automated by using a threshold based on the standard deviation of the radial spread of the filtered waveform ( σradial ). a. As the imaging distance increases, the SNR of the waveform obtained from the radial spread feature decreases. b. σradial can be used as a ground-truth-free indicator of the SNR of the radial spread. This measure σradial is the standard deviation of the radial spread of the filtered waveform. As seen in the plot, low σradial values are linked to low SNR and vice versa. c. A clear bifurcation can be observed in the histogram of σradial , plotted across all trials. We choose 0.28 as the threshold for our dataset. We use the waveform from the radial feature only if its σradial crosses this threshold.
Figure 5: Heart rate (HR) can be accurately estimated by detrending and filtering the estimated signals, demonstrated here on the eSPG signal. a, The raw signal can be extracted from the event stream via statistical features. b, The raw signal is detrended to produce the pulsatile signal and remove the baseline wander. c, The pulsatile signal is denoised with a Butterworth filter to yield the eSPG waveform. d, The filtered waveform encodes the HR, which can be spectrally extracted from its power spectral density.
Hyperparameter
Value
Common
Detrend
True
Spectral estimator
Welch
Pulse-rate band
40 – 360\penaltyBPM
HR estimate
argmaxfP(f)+P(2f)
Filtering
Zero-phase (forward–backward)
Event Camera
Resolution (H × W)
720×1280
Table 4: Camera specifications and hyperparameters used to estimate plethysmography waveforms and compute the HR from the event- and frame-based cameras. These configurations are kept constant across all trials and distances. All preprocessing, except the filter order, is kept the same across modalities when computing the HR from the power spectral density.
Event Camera
Frame Camera
Condition
f/#
OFF
ON
HPF
f/#
Exposure ( μ s)
Short range
Laser profile (Uniform/Gauss)
6
150
100
0
6
1000
Handheld sub- mW laser + hand hovering
6
80
20
100
6
1000
Ambient light
6
80
20
0
6
500
All others
6
80
20
0
6
1000
Mid range
All
1.8
30
−10
0
1.8
1400
Table 5: Camera parameters used during acquisition. Event camera bias parameters: OFF and ON are the parameters that control the contrast thresholds ( bias_diff_off and bias_diff_on ). That is, they control the threshold that a pixel’s brightness change must exceed to fire an event with negative and positive polarity, respectively. Higher values reduce sensitivity and noise. HPF is the high-pass filter parameter ( bias_hpf ); higher values suppress slower changes in brightness. All other biases were set to 0 .
Symbol
Value
Definition and qualification
u
1000m
Imaging distance.
f
1.5m
Telescope focal length.
f/D
5
Telescope f-number.
D
0.300m
Entrance pupil diameter, D=f/5 .
P
5mW
Laser power; assumed to fully reach the palm.
A
0.010m2
Approximately 10cm×10cm illumination area.
Table S1: Inputs for the 1 km sensor-plane illuminance estimate.
Symbol
Value
Value and physical significance
u
1000m
Imaging distance.
f
1.5m
Telescope focal length.
f/D
5
f-number; determines collection cone.
D
0.300m
Derived from D=f/5 ; entrance-pupil diameter.
P
5mW
Laser power; assumed to fully reach the palm.
A
0.010m2
Approximately 10cm×10cm measured spot; uniform illumination approximation.
Table S2: Inputs for the 1km SNR-constraint calculation.
Figure S1: Short-range ( <1m ) experiments: Our proposed method is robust to motion and ambient light. (a) Shows the experimental setup. (b) In Set A, we capture the palm measurement while the palm is still. (c) In Set B, we aim a classroom pointer laser at the palm and hover the palm, simulating a jittering motion. (d) In Set C, we flood-illuminate with large amounts of ambient light to further test robustness. Our method performs best across all the above conditions.
Figure S2: eSPG detects cuff-induced vascular occlusion, thus demonstrating its ability to detect hemodynamic changes. We plot the "Goodness Metric" [ 30 ] of estimated eSPG, iSPG [ 49 ] , and the GT PPG signals for 10 participants (short-range). Here, the solid line represents the mean across the participants, while the spread captures the variation within the 10th−90th percentile. The 2\penaltymin recording can be decomposed into 5 parts: the pre-occlusion still phase ( 30\penaltysecs ), the pressure ramp-up phase ( 15\penaltysecs ), the full-occlusion phase with steady 140\penaltymm Hg cuff pressure ( 30\penaltysecs ), the pressure ramp-down phase ( 15\penaltysecs ), and the post-occlusion phase ( 30\penaltysecs ). As the pressure in the cuff increases, the Goodness Metric drops rapidly, with the eSPG nearly flatlining under full occlusion. This trend is observed across the dataset, as evidenced by the narrow percentile spread.
Figure S3: Heart rate variability (HRV) and respiratory rate (RR) can be estimated from the statistical and spectral properties of the eSPG signal. We denoise the estimated eSPG signals via an analysis-by-synthesis workflow. We fit a Gaussian mixture at each pulse and estimate the interbeat interval (IBI) from the synthesized waveform. The IBI signals can be used to calculate downstream HRV statistics. Further, its PSD also gives us the RR.
GT
eSPG (ours)
iSPG
Participant
SDNN
RMSSD
Weights
Δ SDNN
Δ RMSSD
Weights
Δ SDNN
Δ RMSSD
p1
47.3
43.7
0,0,0,10
−9.3
−8.4
0,10,0,10
−3.7
−0.6
p3
32.0
43.2
0,0,0,10
−9.0
−13.7
0,10,0,10
−2.8
−7.8
p4
70.1
41.7
0,0,0,10
+8.0
+40.2
0,10,0,10
+2.7
+13.0
p5
118.7
139.0
0,0,0,10
+7.5
+17.1
0,10,0,10
+1.9
+6.0
p6
44.0
58.6
0,0,0,10
−7.8
−9.1
0,10,0,10
−2.4
−4.6
Table S4: HRV error per trial . We report the Standard Deviation of NN intervals (SDNN) and the Root Mean Square of Successive Differences (RMSSD) for our method (eSPG) and the baseline (iSPG). Δ is the error calculated as the estimate minus the ground truth. All metrics - SDNN, RMSSD, and their errors - are measured in milliseconds( ms ). Each participant’s Gaussian-fit estimate uses the loss weights picked without them, by leave-one-participant-out on the MAE of RMSSD. Weights are λfreq , λHR , λIBI , λjit .
Trial
GT
eSPG (ours)
iSPG
p1
12.6
+2.4
+0.0
p3
17.8
−1.9
+0.3
p4
20.3
+1.6
+1.5
p5
17.2
−1.6
−1.4
p6
18.5
+0.0
+0.0
p7
8.6
+1.0
+0.9
Table S5: Respiratory rate (RR) modulates the heartbeat and can be extracted from plethysmography signals. We choose the best hyperparameter fit using the LOPO strategy from our HRV analysis. The RR estimated from the pulse oximeter is used as our GT measure. All values are measured in respirations per minute ( RPM ). The method columns are Δ , estimate minus ground truth.
Figure S4: eSPG is more consistent across different imaging distances, each captured using a different focusing optic. a, For short distances ( <1\penaltym ) and a 12.5\penaltymm lens, the error distributions of eSPG and iSPG overlap almost perfectly, showing that the two methods both perform equally well. b, At 100\penaltym with a 135\penaltymm lens, eSPG performs significantly better than iSPG. iSPG achieves lower error on some samples, but eSPG is more consistent, with lower error across the full set. c, d, e, In long-range sensing, with a telescope configuration and laser placed at 60\penaltym , eSPG and iSPG exhibit competitive performance. The eSPG estimates increasingly outperform iSPG at greater imaging distances.
Figure S5: eSPG-based HR estimation surpasses prior work across different imaging conditions. All samples are recordings of the palm at short imaging distances ( <1\penaltym ) with a 12.5\penaltymm lens. a, When the palm remains still, the speckle fluctuations can be sensed equally well with event- and frame-based cameras. b, eSPG is more resilient to changes in laser illumination. This includes changes to the beam profile (Gaussian or uniform) and to the laser power (sub- mW laser pointer). c, Event-based sensing is more robust to motion-induced corruption when compared to frame-based methods. The error distributions are visibly more compact, with fewer individual outliers. d, Imaging in extreme ambient light favors event cameras due to their inherently high dynamic range and relative insensitivity to bright static illumination. e, Moving the laser corrupts the speckle fluctuations captured by both cameras. In this case, iSPG performs marginally better, though both methods yield similar high-error outliers.
Figure S6: Participant distribution across Monk Skin Tone Scale [ 110 ] . The palmar side skin tone is measured at the palm-wrist intersection, while the dorsal side is measured on the back side of the palm.
⋆CVPR Unit, Indian Statistical Institute, Kolkata, India · † Department of Computational and Data Sciences, Indian Institute of Science, Bengaluru, India