cs.LGNov 20, 2026

Cross-Site Transformers Are Robust Heart Rate Estimators

Authors: Mason Kadem, Rong Zheng

Organizations: Department of Computing and Software, McMaster University, Hamilton, Canada

Abstract

Single-site heart-rate estimation from photoplethysmography (PPG) degrades sharply under real-world motion. Multi-site PPG provides a natural solution, but existing models fuse sites as generic sensor channels rather than exploiting their hemodynamic structure: each heartbeat propagates along the arterial tree, appearing across body sites as delayed and transformed copies of the same cardiac event. We propose the Cross-Site Transformer, which introduces a hemodynamically informed inductive bias by restricting multi-sensor fusion to cross-attention between PPG sites. On WildPPG, the largest in-the-wild benchmark available, our model establishes a new single-model state of the art, reducing error by 21% over the previous best and 35% over the best prior transformer. The same cross-site restriction makes the trained network directly auditable. Because each cross-attention head lies on one directed pathway between sites, causal resample ablation can isolate and test each direction of information flow. Ablating the chest-to-wrist pathway doubles error, whereas the reverse costs far less. Encoding hemodynamic structure into attention routing thus improves real-world sensing robustness and enables rigorous auditing of multi-sensor fusion.

Figures & tables

Explore similar work

May 19, 2026

Cross-View Attention Fusion Net: A Prior-Guided Dual-View Representation Learning for Cardiac Output Estimation from Short-Term PPG Signals

Accurate cardiac output (CO) estimation from photoplethysmography (PPG) is promising for unobtrusive hemodynamic monitoring, but remains difficult since CO is jointly determined by cardiac function and vascular tone. Conventional feature-based models use physiologically meaningful PPG descriptors, yet depend on accurate pulse detection and may miss latent temporal relationships. In contrast, fully end-to-end deep learning models learn directly from raw PPG but often underuse established PPG-derived prior information. Here, we introduce the Cross-View Attention Fusion Network (CVAF-Net), a prior-guided dual-view deep learning model for CO estimation from short, fixed-length PPG segments. CVAF-Net processes raw PPG as a temporal view and a feature sequence map (FSM) as a structured prior-guided view, and fuses the two representations through cross-view attention. The model was independently evaluated using 5-, 15-, and 30-s segments from three datasets: simulated pulse waves (3323 subjects), vasoconstriction provocation (79 subjects), and resting/cycling activities (10 subjects), and was compared with multiple machine learning and deep learning benchmarks. CVAF-Net outperformed most benchmark methods and achieved performance comparable to a state-of-the-art Transformer-based model, with a mean absolute error (MAE) of 0.19 L/min (MAPE: 3.95%) on simulated data and high accuracy in real-world settings (minimum MAE: 1.20 L/min). Importantly, CVAF-Net reduced FLOPs by twelvefold compared with the leading Transformer-based model. Plausibility analysis showed physiologically consistent CO estimates, with expected correlations with age (ρ=−0.274ρ= -0.274), heart rate (ρ=0.894ρ= 0.894), and systemic vascular resistance (ρ=−0.740ρ= -0.740). These findings indicate that CVAF-Net provides an accurate, computationally efficient, and generalizable approach for continuous wearable-based CO monitoring.
May 18, 2026

Multi-site PPG: An In-the-Wild Physiological Dataset from Emerging Multi-site Wearables

Wearables are widely used for mobile health monitoring, and photoplethysmography (PPG) is a key sensing modality for heart rate and related physiological measurements. However, public in-the-wild PPG datasets remain largely wrist-centric or limited to short, controlled studies, constraining research on emerging wearable form factors. We present Multi-site PPG, an in-the-wild physiological dataset collected from four custom-developed unobtrusive wearables: a smart earring, ring, watch, and necklace. Each device records green and infrared reflective PPG, 3-axis acceleration, and temperature with timestamps for cross-device alignment, while a Polar H10 chest strap provides reference electrocardiogram (ECG). Participants wore the devices for multiple days during daytime activities while continuing their normal routines. The dataset contains over 350 hours of raw data and 230-290 hours of modeling-ready 8-second windows per wearable. We benchmark heuristic, supervised, and self-supervised heart-rate estimation methods, showing substantial body-site differences: the best methods achieve mean absolute errors (MAEs) of 2.30 bpm on the earring, 5.13 bpm on the ring, 8.37 bpm on the watch, and 8.68 bpm on the necklace. We further analyze motion effects and evaluate multi-site and PPG-accelerometer fusion, demonstrating the dataset's value for robust physiological sensing across emerging wearable form factors.
Jul 29, 2026

PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimation

Remote photoplethysmography (rPPG) enables non-contact heart-rate estimation from facial videos, but its weak physiological signal is easily corrupted by motion, illumination changes, occlusion, skin-appearance variation, and device noise. Existing rPPG methods typically rely on a single model to directly predict heart rate or recover pulse waveforms, while different strong estimators may produce conflicting yet individually plausible candidates for the same video. To resolve these conflicts, we propose PhysAgent, an inference-time multi-agent candidate-verification framework. Unlike direct prediction approaches, PhysAgent neither trains a new base rPPG model nor asks Multimodal Large Language Models (MLLMs) to output heart rate directly. In contrast, it treats outputs from multiple base estimators as physiological hypotheses to be verified and uses a lightweight 4B MLLM, Qwen3-VL-4B, to drive multi-agent reasoning over video conditions, signal reliability, and candidate disagreement. A deterministic physiological verifier checks the fusion proposal, and a reproducible numerical fusion process produces the final heart rate. Experimental results on multiple public rPPG benchmarks show that PhysAgent improves fusion stability and reliability across different datasets and source-domain settings, while avoiding the irreproducibility and physiological inconsistency of direct MLLM prediction or unconstrained ensemble fusion. The code will be released soon.