Organizations: The Chinese University of Hong Kong · Shenzhen Loop Area Institute · Shenzhen University · The Hong Kong University of Science and Technology (Guangzhou) · Guangdong University of Technology · Southern University of Science and Technology
Existing surgical world models often leave implicit how instrument motion drives localized tissue responses and how interaction history informs subsequent actions. We introduce KineState-SWAM, a surgical world-action model coupling action prediction and video generation through a persistent interaction state, separating kinematically determined instrument motion from learned scene evolution. A flow-matching policy predicts joint trajectories conditioned on interaction state, robot configuration, and task instruction. Kinematic Geometry Conditioning converts these trajectories into surface-motion tokens and spatially aligned instrument renderings using calibrated URDF kinematics. Causal Interaction Dynamics recurrently updates the state through geometry-guided attention and motion-aligned feature transport, carrying interaction history into subsequent action predictions without intermediate video synthesis. The State-Geometry Adapter combines state-dependent spatial modulation with localized geometric residuals to guide video generation. Interaction-aware supervision emphasizes tissue responses near instrument working regions. We introduce dVRK-Chole5.2k, comprising 5,255 videos spanning 17 surgical tasks. Experiments demonstrate improved action accuracy and video fidelity over evaluated baselines within matched action-conditioning settings. Ablations support preserving and transporting interaction states for long-horizon prediction.
Figures & tables
Figure 1: Comparison of world-modeling paradigms and KineState-SWAM. Our model predicts robot actions and uses their URDF-derived motion to update a persistent interaction state, which guides subsequent action prediction and video generation.
Figure 2: The flow-matching Action Policy predicts future robot joint trajectories, which are transformed into explicit instrument-motion and rendering conditions through calibrated URDF kinematics. Causal Interaction Dynamics recurrently updates a persistent interaction state, while the State–Geometry Adapter injects complementary state and geometric conditions into a pretrained video DiT.
Methods
Backbone (B)
SSIM ↑
PSNR (dB) ↑
LPIPS ↓
FVD ↓
FID ↓
Flow EPE ↓
Flow MR →1
Action-Free Video Generation
CogVideoX1.5 [ 19 ]
5
0.665
15.482
0.477
345.436
42.072
1.309
0.649
HunyuanVideo-1.5 [ 17 ]
8.3
0.732
17.462
0.348
104.288
24.091
0.785
0.694
Cosmos-H-Predict [ 6 ]
2
0.713
17.492
0.339
147.821
30.445
0.892
0.682
Wan2.2 [ 15 ]
5
0.737
18.510
0.297
109.299
22.314
0.736
0.857
Predicted-Action Video Generation
Table 1: Video-generation results on dVRK-Chole5.2k under three action-conditioning settings: no future-action conditioning, model-predicted actions ( ∗ ), and ground-truth actions ( ‡ ). Backbone sizes denote the nominal parameter counts of the pretrained video backbones in billions. Bold and underlined values indicate the best and second-best results within each setting, respectively.
Methods
Joint nMAE ↓
Tip ADE (mm) ↓
Tip FDE (mm) ↓
Rot. ( ∘ ) ↓
DreamZero
0.771
28.561
29.861
24.076
OpenWAM
0.583
24.828
28.022
24.187
X-WAM
0.308
8.490
12.071
12.522
KineState-SWAM (Ours)
0.201
5.416
7.267
7.765
Table 2: Action prediction on dVRK-Chole5.2k. Joint nMAE measures normalized joint-space error, while tip ADE, tip FDE, and rotation error are evaluated through forward kinematics.
Figure 3: Phase-wise evaluation of KineState-SWAM across the 17 cholecystectomy subtasks in dVRK-Chole5.2k. The upper timeline indicates the procedural sequence. All evaluation metrics are computed from the model-predicted joint trajectories and their corresponding generated videos, without ground-truth action conditioning.
Figure 4: Qualitative comparison on dVRK-Chole5.2k for grasping and retraction, clip application, and cutting. Frames follow temporal order within each example, with ground truth in the top row. ∗ and ‡ denote predicted-action and ground-truth-action settings, respectively. Colored boxes highlight discrepancies in instrument configuration and local scene structure.
Figure 5: Action-conditioned video generation for three clipping positions and three traction directions. Red arrows indicate the varied instrument motions, and the rightmost column overlays the corresponding URDF geometry for visual comparison.
Figure 6: Ablation of interaction-aware supervision. Green (top) and red (bottom) crops show predictions without and with interaction-aware weighting, respectively. LPIPSint measures interaction-region perceptual error.
Figure 7: Prediction errors over time on the test set for the full model and variants without state transport or state carry. Curves and shaded regions indicate the mean and standard deviation across test sequences. Evaluation is performed on the full test set with variable-length sequences, averaging results at each prediction horizon over sequences with available ground-truth frames.
Control Representation
SSIM ↑
LPIPS ↓
FVD ↓
Flow EPE ↓
Flow MR →1
No Control (Wan2.2)
0.737
0.297
109.299
0.736
0.857
Pose Control
0.752
0.278
105.642
0.721
0.872
Mask Control
0.768
0.251
96.477
0.697
0.887
URDF Render Control
0.790
0.215
81.509
0.651
0.902
Ours
0.819
0.179
63.550
0.607
0.916
Table 3: Comparison of different control representations for surgical video generation using ground-truth actions.
Variant
SSIM ↑
LPIPS ↓
FVD ↓
Flow EPE ↓
Flow MR →1
Causal Interaction Dynamics
w/o Explicit Surface Velocity
0.794
0.205
83.477
0.694
0.881
w/o Geometric Bias
0.811
0.186
68.731
0.629
0.901
w/o State Transport
0.801
0.197
78.908
0.682
0.892
State–Geometry Adapter
Additive State Conditioning
0.809
0.191
76.541
0.667
0.874
Table 4: Ablation of Causal Interaction Dynamics and the State–Geometry Adapter on dVRK-Chole5.2k. Variants remove or replace individual components of the full model.
Shenzhen Loop Area Institute, Shenzhen, China. · Guangdong University of Technology, Guangzhou, China. · The Chinese University of Hong Kong, Hong Kong SAR, China.