Organizations: Mechanical Engineering Department, City University of Hong Kong, Kowloon, Hong Kong SAR · Department of Mechanical Engineering, National University of Singapore, Singapore · Department of Systems Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR · CAS-CityU Joint Laboratory for Robotic Research, City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
Accurate material identification is important for robotic manipulation, yet vision-based methods face challenges when materials have similar appearances. Herein, we report T-Tac, a soft, thin, active thermal tactile sensor that identifies materials through their transient thermal responses. T-Tac integrates a polyimide film heater with an ionic conductive film temperature sensor, providing controlled thermal excitation and resistance-based temperature measurement in a film assembly suitable for mounting on robotic grippers. Single-sided transient plane source modeling and finite element simulations relate the thermal response to material thermal properties, while calibration and repeated measurements characterize the heating and sensing performance. Loading experiments at room and elevated temperatures further characterize the sensor response under an applied force. A hybrid classification framework concatenates extracted thermal descriptors with multiscale convolutional neural network features and uses an ExtraTrees classifier for material prediction. Experiments on 12 materials achieve a mean classification accuracy of 92.69% using a 3 s heating pulse and a 10 s observation window. These results support T-Tac as a compact approach to integrating active thermal material sensing into robotic end effectors. This work shed a light on the new approach for robotic material identification.
Figures & tables
Fig. 1: Device design of the soft thermal tactile sensor (T-Tac), which actively generates and senses transient thermal signals to enable rapid material identification by touch.
Fig. 2: Device fabrication of T-Tac. (a) Optical photographs of the ionic conductive film. (b) Schematic fabrication process of the ionic conductive film.
Fig. 3: Hardware design and system integration of T-Tac, showing PWM-controlled heating, resistance acquisition, and data transfer to the host computer.
Fig. 4: Principle of the thermal heater, a thin PI-based heating film that generates controlled heat through Joule heating while exchanging energy via conduction, convection, and radiation.
Fig. 5: Principle of thermal sensing and transient thermal response. (a) Temperature-dependent ion migration and resistance variation in the ionic conductive film. (b) Single-sided thermal contact and the heating and cooling response produced by pulsed excitation.
Fig. 6: Simulation of the transient thermal response for 12 different materials, showing distinct heating and cooling profiles that reflect their material-dependent thermal properties.
Material
Symbol
k (W·m -1 ·K -1 )
Cp (J·kg -1 ·K -1 )
ρ (kg·m -3 )
Aluminum
Al
205
900
2700
Copper
Cu
385
385
8960
Iron
Fe
80
450
7870
Molybdenum
Mo
138
251
10200
Niobium
Nb
54
265
8570
Nickel
Ni
91
444
8900
TABLE I: Thermal properties of tested materials [ 27 ]
Object
Peak Temp (°C)
Heating Rate (°C/s)
T(t)=T∞+Aexp(−t/τ)
Time constant τ (s)
T∞ (°C)
A (°C)
Al
25.40
0.12
1.70
25.22
1.83
Cu
25.27
0.08
1.61
25.16
1.26
Fe
25.58
0.18
2.47
25.16
2.06
Mo
25.51
0.15
1.90
25.22
2.32
Nb
25.87
0.27
2.49
25.24
3.02
TABLE II: Thermal response parameters of tested materials
Fig. 7: Calibration and performance of the thermal heater. (a) Schematic of the calibration setup. (b) Experimental platform. (c) Temperature variation with heating duration. (d) Maximum temperature at different duty cycles. (e) Maximum temperature during repeated heating.
Fig. 8: Calibration and performance of thermal sensor. (a) Schematic illustration of calibration. (b) Experimental platform of the thermal sensor. (c) Sensing calibration curves of the thermal sensor. (d) Dynamic performance of the thermal sensor. (e) Repeatability performance of the thermal sensor.
Fig. 9: Temperature response of the thermal sensor under a force of 2N . (a) Temperature recorded during the room-temperature and heated stages. (b) Enlarged response near 25.15∘C . (c) Enlarged response near 43.75∘C .
Sensing Parameter
Result
Range
25–80 ∘ C
Fitting equation
r=80.13[exp(−0.04518(x−27))−1]
Average sensitivity
−1.46%/∘ C
Coefficient of determination
0.99
Response time
4.10 s
Repeatability error
0.34
TABLE III: Sensing parameters of the thermal sensor
Fig. 10: Experimental platform for thermal tactile measurements. (a) Tested materials. (b) T-Tac mounted on a robotic gripper. (c) Measurement setup with the displayed transient thermal response during pulsed heating and cooling.
Fig. 11: Material classification framework based on thermal and CNN feature fusion. Thermal descriptors and multiscale CNN features are concatenated and fed into an ExtraTrees classifier for material identification.
Fig. 12: Classification performance at a 10 s observation window. (a) Mean conditional accuracy of the fused classifier, grouped by the correctness of the thermal-feature and CNN-feature classifiers. Blue and red segments indicate correct and incorrect fused predictions, respectively. (b) Confusion matrix of the fused classifier for 12 materials.
Time
Thermal features Accuracy (%)
CNN features Accuracy (%)
Fused features Accuracy (%)
3 s
58.00±5.86
65.03±5.64
65.42±5.38
5 s
87.86±4.32
81.89±4.51
86.14±3.75
8 s
90.36±3.78
86.25±3.68
91.28±3.09
10 s
91.56±3.33
86.78±3.95
92.69±3.59
12 s
90.97±3.50
88.00±3.61
92.53±3.49
15 s
91.06±3.42
89.33±3.22
92.61±3.25
TABLE IV: Classification accuracy at different observation times
Fig. 13: Gripper-mounted thermal sensing examples. (a) Schematic of the measurement and classification interface. (b) Photographs of gripper-mounted measurements with the acquired response and displayed model output.
Work
Thermal mechanism
Sensor structure
Reported timing
Reported result
Mechanical form
[ 30 ]
Active heating
Au heater and Ni RTD on PI substrate
NA
>90% blind test
Flexible film
[ 31 ]
Heated BioTac with thermal and vibration sensing
BioTac fingertip with thermal and vibration channels
0.28 s mean first recognition
1.02% error recursive protocol
Rigid core, soft skin
[ 32 ]
Preheated BioTac with thermal and vibration sensing
BioTac fingertip with thermal and vibration channels
20 s pressing plus sliding
86.19%
Rigid core, soft skin
[ 33 ]
Heated BioTac with thermal and vibration sensing
BioTac fingertip with thermal and vibration channels
0.28 s mean first recognition
98.6%
Rigid core, soft skin
[ 34 ]
Active heating (471 mW DC)
Copper heater, gold RTD, and PDMS encapsulation
15 s static + 10 s sliding
98% 50 trials
Flexible sensing layer
T-Tac
Active pulsed heating (single-sided TPS)
PI heater and ionic film temperature sensor on FPCB substrate
3 s pulse 10 s observation
92.69%
Film assembly
TABLE V: Representative thermal and multimodal tactile systems for material identification
Department of Electrical, Electronic, Telecommunications Engineering, and Naval Architecture (DITEN), University of Genoa, 16145 Genoa, Italy · Department of Computer and Communication Engineering, Lebanese International University (LIU), Beirut, Lebanon