3D-EMCAD: Efficient Multi-scale Convolutional Attention Decoding for Volumetric Brain Tumor Segmentation

Authors: Iftakhar Hossain, Israt Jahan Sinthia, Md. Hadiur Rahman Khan

Organizations: Department of Biomedical Engineering, Bangladesh University of Engineering & Technology (BUET), Dhaka, Bangladesh · Department of Biomedical Engineering, Chittagong University of Engineering and Technology (CUET), Chittagong, Bangladesh · Department of Electrical and Electronic Engineering, Bangladesh University of Engineering & Technology (BUET), Dhaka, Bangladesh

Abstract

Encoder-decoder networks are widely used for volumetric brain tumor segmentation, yet recent trends favor high-capacity decoders that incur steep computational costs in 3D at high spatial resolutions. The Efficient Multi-scale Convolutional Attention Decoder (EMCAD) is a lightweight decoder that achieves strong accuracy at very low cost, but it has been validated only in 2D. Here, we extend EMCAD to volumetric segmentation (3D-EMCAD) by converting all operations to 3D and replacing standard normalization layers with group normalization to suit the small batch sizes of volumetric training. To isolate the impact of decoder choice, we evaluate five decoders: the proposed 3D-EMCAD, a vanilla SegResNet decoder, an Attention U-Net decoder, UNet++, and a plain U-Net decoder using an identical 3D SegResNet encoder and training protocol on BraTS 2020 (369 cases, three-fold cross-validation). The five decoders yield statistically indistinguishable performance: their mean Dice scores span only 0.0071, less than the fold-to-fold variation of most models, and a paired Wilcoxon signed-rank test shows no significant difference between 3D-EMCAD and three of the four baselines. Importantly, 3D-EMCAD achieves this shared accuracy with the fewest decoder parameters (1.15 M) and operations (8.6 G), requiring 7.3×7.3\times fewer operations than UNet++, which scores no higher. These findings demonstrate that decoder capacity beyond a modest budget offers no measurable benefit for volumetric brain tumor segmentation.

Figures & tables

Explore similar work

May 4, 2026

M\textsuperscript{4}Fuse: Lightweight State-Space MoE with a Cross-Scale Gating Bridge for Brain Tumor Segmentation

Encoder-decoder imbalance and the reliance on large input volumes make many 3D brain tumor segmentation models both compute-heavy and brittle. We present M\textsuperscript{4}Fuse, a lightweight network that prioritizes discriminative brain tumor cues over exhaustive appearance reconstruction. Our method balances encoder and decoder capacity and replaces depth expansion with a synergistic design: it propagates long-range context with linear complexity via a grouped state space mixer, denoises and aligns skip features using a cross-scale dual-stage gating bridge, and absorbs cross-site acquisition shifts with a sample-level mixture-of-experts. On the BraTS2019 and BraTS2021 benchmarks, M\textsuperscript{4}Fuse outperforms other lightweight excellent methods in both parameter count and performance. Even at a challenging input resolution of 64×128×12864\times128\times128 (half that of existing excellent models), M\textsuperscript{4}Fuse reduces parameters by 62.63% and improves average performance by 0.09%. Ablations of key components validate the method's exceptional parameter-to-accuracy efficiency and robustness across diverse data centers.
Sep 20, 2026

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

Automated brain tumor segmentation supports diagnosis, treatment planning, and monitoring of disease progression, but building models that generalize across heterogeneous tumors and limited annotated data remains difficult. We present VGG16-MCA UNet, a hybrid architecture pairing an ImageNet-pretrained VGG16 encoder with a decoder in which a Multi-Channel Attention (MCA) module recalibrates features after each skip-connection fusion, trained with the Focal Tversky loss to counter severe foreground-background imbalance. We evaluate the model as a 2D, FLAIR-only, whole-tumor segmenter on tumor-positive slices from two public datasets: the BraTS 2020 benchmark and the LGG MRI Segmentation dataset. Using 5-fold cross-validation and a single network formed by averaging the weights of the five fold models, the method attains an aggregate pixel-level Dice (F1) of 95.10% on our held-out BraTS 2020 split and 88.32% on LGG. These scores are computed over all test pixels pooled into a single confusion matrix rather than averaged per case, and are therefore not directly comparable to the per-case mean Dice used in the BraTS challenge protocol. All partitions were drawn over individual slices rather than over patients, so every patient contributes slices to both training and test; the figures above therefore measure interpolation within known patients and should be read as an upper bound rather than as generalization to new ones. The model segments a 256x256 slice in 66.32 ms on a single 6 GB NVIDIA RTX 2060, approximately 8 ms more than an equivalent VGG16-UNet without MCA. We release the split records and report the protocol in full, with the aim of providing a precisely specified and reproducible 2D FLAIR baseline.
May 6, 2026

DALight-3D: A Lightweight 3D U-Net for Brain Tumor Segmentation from Multi-Modal MRI

Automatic brain tumor segmentation from multi-modal MRI remains challenging because volumetric models often incur substantial computational cost. This paper presents DALight-3D, a compact 3D U-Net variant that combines depthwise separable 3D convolutions, identifier-conditioned normalization, cross-slice attention, and adaptive skip fusion. The method is evaluated on the Medical Segmentation Decathlon Task01 BrainTumour benchmark under matched optimization settings against standard 3D U-Net, Attention U-Net, Residual 3D U-Net, and V-Net baselines. In the reported 50-epoch comparison, DALight-3D achieves a mean Dice of 0.727 with 2.22M parameters, compared with 0.710 Dice and 3.20M parameters for Residual 3D U-Net. Component-wise ablations show consistent performance degradation when SepConv, identifier-conditioned normalization, CSA, or SSFB is removed. These results indicate that DALight-3D offers a favorable accuracy-efficiency trade-off within the present benchmark setting.