Scalp electroencephalography (EEG) is routinely denoised before it reaches a downstream model, and the denoising literature scores a method by how closely its output matches a clean reference waveform. That reference does not exist for real scalp recordings: it is synthesized by adding artifact templates to signals merely presumed clean, and even an exact separation would return cortical activity blurred by volume conduction rather than the activity itself. Fidelity to it is therefore an unvalidatable objective, and whether it predicts any downstream benefit has gone largely unexamined. We report an audit that examines it. Holding a seizure-detection pipeline fixed and varying only the preprocessing stage, we find that five standard denoising methods, spanning analytic, cross-channel and supervised deep families, all fail to improve on the unprocessed signal, and most degrade it. To say what such a stage must instead do, we formalize a label-only, classifier-free probe that reads it by the separability geometry it induces on task-relevant features, decomposing any change into a between-class distance and a within-class scatter term. On a transform that does improve the task, the probe attributes the entire gain to a roughly one-quarter reduction of within-class scatter, with class separation statistically unchanged. What a downstream model benefits from is therefore variance suppression on task-relevant structure, which waveform-fidelity metrics neither measure nor reward.
Figures & tables
Preprocessing
BF1
Sn
Pr
BAcc
MCC
AUROC
None (raw signal)
0.681
0.717
0.706
0.852
0.688
0.955
Wavelet thresholding
0.657
0.733
0.654
0.852
0.662
0.955
ASR
0.667
0.732
0.690
0.848
0.674
0.953
ICA
0.661
0.697
0.705
0.841
0.671
0.956
EEGdenoiseNet (EOG)
0.604
0.651
0.630
0.817
0.611
0.945
EEGdenoiseNet (EMG)
0.626
0.661
0.650
0.823
0.631
0.939
TABLE I: Downstream seizure detection on CHB-MIT with EEGWaveNet as the host. Every row differs only in the preprocessing occupying one fixed position in the pipeline; the host, its training protocol, the cross-validation split and the metrics are identical throughout. Scores are means over 22 patients, as reported in [ 13 ] .
Fig. 1: Decomposing the separability change under the positive control, over 22 patients. (a, b) Noise suppression: within-class scatter σˉwithin falls by about a quarter. (c, d) Pattern separation: the between-class centroid distance Δbetween is unchanged. Axis labels: Raw is the unprocessed signal, Reprogrammed the positive-control output. Dots are individual patients, joined between conditions; ∗∗∗p<0.001 , NS = not significant, cross-patient Wilcoxon signed-rank. Adapted from [ 13 ] .
Fig. 2: Per-descriptor separability before and after the positive control. Each panel is one morphology descriptor, each dot a per-patient standardized mean difference between ictal and interictal windows, joined across conditions ( Reprogrammed denotes the positive-control output). All six improve significantly ( ∗p<0.05 , ∗∗p<0.01 , ∗∗∗p<0.001 ), so the joint gain is broad rather than carried by any single statistic. Adapted from [ 13 ] .
Deep learning EEG denoising architectures have scaled from tens of thousands to tens of millions of parameters, yet no prior study has isolated model capacity as the experimental variable or tested whether reconstruction metrics predict downstream neural-signal utility. We address both gaps by fixing architecture, loss, data split, and training recipe while sweeping only channel width from 1.05K to 40.26K parameters in a minimal depthwise-separable convolutional U-Net. Models were evaluated on the EEGDenoiseNet benchmark, cross-dataset BCI transfer tests, controlled baseline retraining, and downstream motor-imagery classification with five decoder families across all nine BCI Competition IV-2a subjects. Reconstruction performance saturated by 3-6.5K parameters, with post-elbow gains of at most 0.015 correlation coefficient per log10-parameter unit. An 8.46M-parameter baseline retrained under the same pipeline matched the 40.26K compact variant on EOG--a 200x parameter gap yielding no advantage--while a Patch-Transformer control reproduced the same diminishing-return shape. Downstream evaluation exposed a classifier-dependent metric-utility gap: reconstruction-optimized denoising significantly degraded CSP+LDA classification across all nine subjects and three artifact types (best denoised accuracy 0.547 vs. 0.612 noisy baseline; Bonferroni p=0.0488), persisting on naturally recorded trials (Delta=-0.047; BH-FDR q=0.0049). End-to-end neural decoders showed variable or neutral effects. Standard EEG denoising benchmarks are saturated far below current model capacity, and reconstruction metrics do not predict BCI utility. Ultra-compact models at 33-46 KB and 1.27-2.61M FLOPs/segment are practical for edge deployment. These findings argue for capacity-controlled evaluation, harder task-aware benchmarks, and mandatory downstream validation.
Jasmeet Singh Bindra, Siddharth Panwar
Indian Knowledge Systems and Mental Health Applications (IKSMHA) Center, Indian Institute of Technology Mandi, Himachal Pradesh, India · School of Computing and Electrical Engineering, Indian Institute of Technology Mandi, Himachal Pradesh, India
Denoising wearable electroencephalogram (EEG) is inherently challenging since neural activity is not only subtle but also inseparable from spectrally overlapping noise artifacts. Classical signal processing methods, relying on fixed or heuristic rules, cannot handle the time-varying pervasive artifacts in wearable EEGs. Deep learning methods, on the other hand, show promise in decomposition-free EEG denoising using highly expressive neural networks, but the training requires artifact-free EEG, which is inherently unobtainable. To address this, we propose Intelligent Partitioning for Self-supervised Denoising (iPSD). Our method eliminates the need for clean references by learning to partition an input EEG segment into independent noisy realizations with the same underlying signal. This enables self-supervision of deep learning denoisers, even in zero-shot settings where only a single EEG segment to be denoised is available. We validate iPSD through extensive experiments, including validations on wearable EEG from in-ear sensors. The results show that iPSD achieves state-of-the-art performance, most notably under extremely low signal-to-noise ratios (down to -10 dB) and challenging artifacts (e.g., EMG), with spectral fidelity orders of magnitude higher than competitive baselines.
Qiyu Rao, Haozhe Tian, Homayoun Hamedmoghadam +1
Department of Electrical and Electronic Engineering, Imperial College London · Dyson School of Design Engineering, Imperial College London
Electroencephalography (EEG) is a cornerstone of brain-computer interfaces and clinical neuroscience, yet deep learning models are typically trained and evaluated under a single, unreported preprocessing pipeline. We formalize preprocessing choices as a counterfactual intervention space and show that EEG predictions are surprisingly unstable under this space: across six datasets spanning four paradigms, up to 42% of trial-level predictions flip when only the preprocessing changes, a variability that standard uncertainty methods do not explicitly quantify because they condition on a fixed preprocessing pipeline. We provide three tools to make this instability measurable, decomposable, and reducible. First, a Walsh-Hadamard decomposition of the 2^7 pipeline space reveals that sensitivity is near-additive in practice under the binary intervention design, enabling efficient step-by-step optimization. Second, we introduce Preprocessing Uncertainty (PU), a per-trial diagnostic that captures a dimension of instability complementary to model-based confidence. Third, we study Normalized Adaptive PGI (NA-PGI), a graph-structured regularizer that exploits the compositional structure of preprocessing interventions as one mitigation strategy with clear scope conditions.
Dengzhe Hou, Zihao Wu, Lingyu Jiang +3
Tohoku University · University of Georgia · Texas A&M University +1