cs.CVNov 22, 2026

A Multi-Criteria Evaluation of Color Normalization Methods in Histopathology: Nuclei Preservation, Artifact Sensitivity, Background Fidelity, and Downstream Performanc

Authors: Falah Jabar, Aria Torkpour, Pasquale Lombardi, Masoud Tafavvoghi, Per Niklas Benzler Waaler, Sigve Andersen, Ilona Urbarova, David J. Pinato, 

Organizations: Dep. of Clinical Pathology, University Hospital of North Norway, Tromsø, Norway. · Dep. of Surgery and Cancer, Imperial College London, London, United Kingdom. · Dep. of Medical Biology, UiT The Arctic University of Norway, Tromsø, Norway. · Dep. of Clinical Medicine, UiT The Arctic University of Norway, Tromsø, Norway. · 

Abstract

Deep learning models for nuclei detection and classification may generalize poorly across medical centers because of variations in staining and scanning. Although color normalization aims to reduce these variations, its effects on nuclear structure, background preservation, artifact sensitivity, and nuclei detection and classification performance have not been systematically evaluated. We present a procedure to benchmark 11 classical and deep learning normalization methods using 7 public and private nuclei datasets. Additionally, we investigate the effect of 7 input color spaces. The normalization methods differed in their effects on nuclear structure, background, and sensitivity to artifacts. However, detection and classification performance varied more across datasets than across normalization methods, and the input color space had limited influence. No single method performed best on all criteria, and image-level metrics did not reliably predict downstream performance, highlighting the need for nuclei- and structure-aware normalization methods. To support this work, we introduce WSI Quality Control and Normalization (WSI-QCN), a publicly available pipeline for robust whole-slide image quality assessment and color normalization; the source code is available on GitHub.

Explore similar work

Sep 1, 2026

StainPresetNet: Stain Preset Network for Fast Multi-to-Multi Stain Normalization

Stain normalization reduces color variations caused by variations in staining protocols and imaging conditions, thereby enhancing computer-aided diagnostic system performance. Traditional methods derive mapping relationships from individual or limited reference images through pixel-wise transformation, offering style flexibility but suffering from inaccurate color mapping extraction. While existing deep-learning-based approaches achieve accurate dataset-wide color mapping through complex neural networks, they face challenges including computational inefficiency, artifact generation, and fixed normalization directions requiring model retraining for directional changes. To address these limitations, we propose StainPresetNet - a novel framework that combines structural preservation with dataset-level color mapping while maintaining computational efficiency. Our method implements pixel-wise normalization guided by preset reference images, enabling multi-directional adaptability without retraining. Evaluations on cytopathology and histopathology datasets demonstrate that StainPresetNet achieves superior color mapping accuracy compared to conventional methods, effectively improves classifier generalization in diagnostic tasks, and reduces computational overhead by 90% versus existing deep learning approaches. The proposed preset-guided mechanism facilitates flexible adjustment of normalization directions through simple reference image replacement, overcoming the directional rigidity of current deep-learning-based solutions.
Mar 4, 2026

DeNuC: Decoupling Nuclei Detection and Classification in Histopathology

Pathology Foundation Models (FMs) have shown strong performance across a wide range of pathology image representation and diagnostic tasks. However, FMs do not exhibit the expected performance advantage over traditional specialized models in Nuclei Detection and Classification (NDC). In this work, we reveal that jointly optimizing nuclei detection and classification leads to severe representation degradation in FMs. Moreover, we identify that the substantial intrinsic disparity in task difficulty between nuclei detection and nuclei classification renders joint NDC optimization unnecessarily computationally burdensome for the detection stage. To address these challenges, we propose DeNuC, a simple yet effective method designed to break through existing bottlenecks by Decoupling Nuclei detection and Classification. DeNuC employs a lightweight model for accurate nuclei localization, subsequently leveraging a pathology FM to encode input images and query nucleus-specific features based on the detected coordinates for classification. Extensive experiments on three widely used benchmarks demonstrate that DeNuC effectively unlocks the representational potential of FMs for NDC and significantly outperforms state-of-the-art methods. Notably, DeNuC improves F1 scores by 4.2% and 3.6% (or higher) on the BRCAM2C and PUMA datasets, respectively, while using only 16% (or fewer) trainable parameters compared to other methods. Code is available at https://github.com/ZijiangY1116/DeNuC.
Oct 16, 2026

Benchmarking and Improvement of Artifact Segmentation Methods in H&E-Stained Whole Slide Imaging

Technical artifacts introduced during tissue preparation or slide scanning remain a major obstacle to developing robust computational pathology algorithms for hematoxylin and eosin (HE)-stained whole-slide images (WSIs). Despite the growing number of quality-control tools, their real-world utility remains hard to assess because of the limited number of publicly available implementations and the lack of systematic, multi-dataset comparisons. This paper presents a benchmark of artifact segmentation methods for HE-stained WSIs. After a literature review, six publicly available algorithms were selected and compared in terms of their ability to segment artifact-free tissue and selected artifact classes. Two publicly available datasets and a newly introduced dataset released to support further research were used for evaluation. Tissue samples from multiple medical centers and different organs are included, enabling evaluation across heterogeneous data sources. Segmentation performance was assessed using Dice Index, pixel-level recall, and false discovery rate for artifact-free tissue segmentation. For algorithms supporting multiclass artifact segmentation, class-wise Dice Index and inter-class misclassification were evaluated. In addition to segmentation quality, processing time was assessed. Statistical analysis revealed significant differences in segmentation performance between methods. HistoKit, which incorporates a modified version of the GrandQC, was identified as the best-performing algorithm, while HistoQC was the worst. In terms of artifact types, dark spots and out of focus regions were harder to segment than others. Finally, a simple post-processing step was introduced for HistoKit, which further improved segmentation performance. The benchmark establishes a reference for evaluating and developing artifact segmentation methods for HE-stained WSIs.