FASCIA: Seeing Beneath the Surface with Queryable, Personalized Anatomy in Any Pose
Authors: R. James Cotton, Tim Unger, Lucinda Williamson
Organizations: Shirley Ryan AbilityLab · Department of Physical Medicine and Rehabilitation, Northwestern University · Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland · Therapy Science Lab, Lake Lucerne Institute (LLUI), Vitznau, Switzerland
We present FASCIA (Functional Anatomical Structures and Composition via Implicit Atlas), a Momentum Human Rig (MHR)-anchored framework that predicts and poses a person's internal anatomy from their external body shape and skeletal proportions. FASCIA maps a single 290-structure population template onto each individual through a smooth, invertible warp. As people with the same shape can differ internally, a body-dependent Gaussian prior predicts both average warp coordinates and their inter-subject variability. The warp deforms a learned base template into bones, muscles, organs, and fat depots. Extending MHR skinning into the interior enables direct supervision of this model across four automatically labeled CT cohorts and one whole-body MRI cohort. On 82 held-out CT scans, FASCIA reaches a mean volumetric Dice (volume agreement) of 0.48 on named bones and 0.63 on muscles, keeps the majority of bones and muscles in one piece, and yields calibrated voxel probabilities. On 33 held-out whole-body MRI subjects, FASCIA's pointwise field improves tissue overlap over HIT across all compartments, predicts between-person differences in whole-body adipose percentage (R2=0.88 vs. 0.38 in women and 0.54 vs. −0.01 in men), and recovers segment centers of mass within 1.1 mm. Because it needs only an MHR fit, FASCIA can be driven from images, video, or any system that outputs MHR. This opens the door to fitting individualized calibrated musculoskeletal digital twins to video motion data.
Figures & tables
Figure 1: FASCIA overview and architecture. Top (a–e): (a) Fit MHR (θ,β,s) to each training scan while retaining its partial labels A(y) . (b) Canonical xc , body code z , and pose θ yield 290-structure probabilities P(k∣xc,z) and posed location y=Φ(xc) . (c) Partial-label supervision estimates template T , per-scan warps, and warp prior (μθ,σ,gθ) . (d, e) Fitting MHR to any input (video, motion capture, or 3D scan) drives posed anatomical meshes, cross-sections, and BSIPs. Bottom (f–h): (f) Gaussian warp prior maps z to mean α^ and draws α(d) driving velocity vα and pullback xT=ψα(xc) into Tk(xT) . (g) Forward posing map y=Φ(xc) combines MHR interior skinning and blendshapes with scanner-table offset δs . (h) Three-stage multi-cohort training.
Table 1: Subject-disjoint training and test cohorts. a Official 317/41/40 splits after registration quality control.
Figure 2: Predicted anatomy on held-out subjects. (A) Six nested canonical layers carried by the FASCIA mean warp. (B) Coronal and sagittal CT reference versus FASCIA cross-sections. (C) Axial CT sections across fine anatomical structures and coarse tissue groups with level-set interfaces ( ∂ ). (D) Held-out MRI sections comparing ground truth, HIT ( Keller et al., 2024 ) , and FASCIA (coarse tissues and full anatomy).
Figure 3: Whole-body MRI tissue composition and segment inertial parameters. (a) Held-out MRI Dice ( n=33 ) comparing FASCIA and HIT ( Keller et al., 2024 ) by sex on appendicular Limb muscle , Lean + visc. fat , subcutaneous fat, and cortical bone. (b–e) Predicted versus true volume percentages for subcutaneous fat (b) , limb muscle (c) , cortical bone (d) , and visceral fat (e) (HIT: 0% , merged in LT ); open circles and dashed lines denote HIT, filled circles and solid lines denote FASCIA, colors match (a, f) (teal: female; blue: male), dotted lines mark 1:1 identity, and insets report per-sex slopes. (f) Segment center-of-mass 3D location error (mm) on trunk, thigh, and shank comparing FASCIA and HIT by sex.
Method
LT+VAT / AT / Bone Dice (F)
LT+VAT / AT / Bone Dice (M)
Adipose % R2 (F / M)
SD ratio (F / M)
CoM (mm)
MOI (%)
Anthropometric tables ( Dumas et al., 2007 )
—
—
—
—
12.5–45.6
13.5–38.5
Uniform-density hull
—
—
—
—
0.73–1.60
1.60–4.70
Stature + mass regression
—
—
0.86 / 0.75
0.81 / 0.76
—
—
HIT ( Keller et al., 2024 )
0.844 / 0.746 / 0.557
0.859 / 0.683 / 0.627
0.38 / -0.01
0.42 / 0.20
0.81–1.42
0.77–3.12
FASCIA pointwise field f(xc,z)
0.865 / 0.857 / 0.629
0.873 / 0.787 / 0.640
0.88 / 0.54
0.96 / 0.96
0.55–1.11
0.49–2.23
FASCIA pointwise field + mass calibration
0.865 / 0.857 / 0.629
0.873 / 0.787 / 0.640
0.89 / 0.87
1.06 / 0.90
0.55–1.11
0.34–1.62
Table 2: Held-out whole-body MRI benchmark ( n=33 : 20 female, 13 male). Voxel Dice is reported for lean tissue plus visceral fat (LT+VAT), subcutaneous adipose tissue (AT), and cortical bone (HIT’s three non-background classes; FASCIA also resolves visceral adipose tissue separately). On MRI, FASCIA is read through its pointwise field f(xc,z) (three seeds, averaged per subject). Adipose % R2 evaluates whole-body adipose fraction; SD ratio is the predicted over the true cohort standard deviation (1.00 means the predicted inter-subject spread matches the ground-truth spread). CoM and MOI give the range of segment center-of-mass error (mm) and principal moment-of-inertia error (%) across trunk, thigh, and shank in both sexes. Mass calibration rescales regional volumes to the reference hull and applies the Archimedes mass-balance update.
Figure 4: Template-and-warp predictions and posterior samples on held-out CT. (a, b) Predicted cortical skeleton and musculature on a held-out CT scan comparing ground truth, pointwise ablation, unwarped template ( α=0 ), FASCIA mean warp, one posterior draw ( Eq. 2 ), and 16-draw probability SD. (c) Posterior-oblique thorax showing intact warped ribs and scapulae versus pointwise fragmentation.
Structure
Zero warp
Pointwise f(xc,z)
FASCIA
Oracle warp
Named bones (79)
0.361
0.411 / 71%
0.476 / 93%
0.622 / 95%
Ribs
0.165
0.101 / 29%
0.258 / 85%
0.418 / 90%
Scapulae
0.263
0.267 / 18%
0.404 / 100%
0.533 / 100%
Muscles (108)
0.505
0.586 / 85%
0.634 / 98%
0.785 / 98%
Organs & vessels
0.346
0.423 / 78%
0.459 / 81%
0.593 / 81%
Subcutaneous fat
0.761
0.751
0.813
0.875
Table 3: Held-out CT ablation on the 5 mm canonical lattice ( n=82 scans). Cells report mean volumetric Dice / single-piece rate (%; bold marks the best label-blind predictor). Zero warp ( α=0 ) evaluates the unwarped template T (Dice only), subcutaneous fat forms a single outer sleeve (Dice only), and Oracle warp fits each scan’s labels directly with T fixed (upper bound).
Figure 5: Driving FASCIA from monocular images via B3D. De-identified COCO-2017 ( Lin et al., 2014 ) examples (rows 1–2): (a) Face-blurred RGB inputs. (b) B3D surface fit and height-calibrated biomechanical STL skeleton. (c) Posed FASCIA cortical skeleton. (d) Posed musculature and segment inertia ellipsoids.
With the growing demand for realistic virtual humans, parametric body models have become a cornerstone of modern medicine, sports, and entertainment applications. However, most of these models are inherently limited: they only capture the 3D surface of the skin, offering no insight into the complex bio-mechanical structures that generate motion. As more applications expand towards biomechanics, the need for virtual human models that go beyond the skin has become increasingly evident. Traditional soft-tissue simulations, such as FEM, are accurate but non-scalable and too computationally expensive for most common applications. Alternatively, existing biomechanical tools can simulate muscular forces and activations, but do not model changes in external shape, restricting how activations correlate with actual observable anatomy. This motivates a novel inverse research problem: recovering muscle deformations directly from visible surface observations - i.e., from the skin, and thus the pose. In this work, we present SOMA (from Surface Observations to Muscle Anatomy), a person-specific model that infers spatio-temporal muscle behavior from surface signals obtained using RGB cameras, and SKIM, a subject-specific soft-tissue deformation dataset. To the best of our knowledge, this is the first method that attempts to recover muscle deformations from multi-view RGB data. We show how our method provides anatomically grounded animations without the complexity of traditional simulations, leading to a scalable and cost-effective solution. Data and code are available.
Eduardo Alvarado, Emily Kim, Gerrit Nolte +4
Max Planck Institute for Informatics, Saarland Informatics Campus · TU Dortmund University
Parametric human body models are foundational to human reconstruction, animation, and simulation, yet they remain mutually incompatible: SMPL, SMPL-X, MHR, Anny, and related models each diverge in mesh topology, skeletal structure, shape parameterization, and unit convention, making it impractical to exploit their complementary strengths within a single pipeline. We present SOMA, a unified body layer that bridges these heterogeneous representations through three abstraction layers. Mesh topology abstraction maps any source model's identity to a shared canonical mesh in constant time per vertex. Skeletal abstraction recovers a full set of identity-adapted joint transforms from any body shape, whether in rest pose or an arbitrary posed configuration, in a single closed-form pass, with no iterative optimization or per-model training. Pose abstraction inverts the skinning pipeline to recover unified skeleton rotations directly from posed vertices of any supported model, enabling heterogeneous motion datasets to be consumed without custom retargeting. Together, these layers reduce the O(M2) per-pair adapter problem to O(M) single-backend connectors, letting practitioners freely mix identity sources and pose data at inference time. The entire pipeline is fully differentiable end-to-end and GPU-accelerated via NVIDIA-Warp.
We propose Skelebones, a Scaffold-Skin Rigging System built on three steps: (1) Bones compress temporally consistent Gaussian or mesh sequences into free-form bones with smooth skinning weights, approximating non-rigid deformations via linear blend skinning (LBS); (2) Skeleton extracts the Mean Curvature Skeleton (MCS) from the canonical shape and temporally refines its topology and kinematics into a compact skeletal structure; and (3) Binding connects the skeleton and bones through non-parametric Partwise Motion Matching (PartMM), which synthesizes novel bone motions by matching, retrieving, and blending existing ones. Together, these steps compress the dynamics of 4D shapes into compact skelebones that are simultaneously controllable and expressive. The resulting representation is category-agnostic, meaning template-free; motion-adaptive, with dynamic topology; and topology-correct, with a skeleton consistent with the surface geometry. PartMM requires no learning. We validate our method on both synthetic and real-world datasets, achieving substantial reanimation improvements on unseen poses: a 17.3 dB PSNR gain over LBS on DNA-Rendering and a 45.6 dB gain over Bag-of-Bones on ActorsHQ, while preserving high rendering fidelity for characters with complex non-rigid dynamics. PartMM generalizes robustly to both Gaussian and mesh representations, excelling in low-data regimes of approximately 1,000 frames, with a 48.4 RMSE improvement over LBS and improvements of more than 20 over GRU- and MLP-based methods. Code will be publicly released at https://cookmaker.cn/gaussianimate/.
Jiaxin Wang, Dongxin Lyu, Zeyu Cai +4
Westlake University, Hangzhou, China · Nanjing University, Nanjing, China · The University of Hong Kong, Hong Kong, China +1