Organizations: Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China · Institute of Research and Clinical Innovations, Neusoft Medical Systems Co., Ltd., Hangzhou, China · Department of Radiology, Beijing Hospital, Beijing, China · Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China · Department of General Surgery, Children’s Hospital, Zhejiang University School of Medicine, Hangzhou, China · Department of Electrical and Electronic Engineering, University of Nottingham Ningbo China, Ningbo, China
Fetal brain diffusion magnetic resonance imaging (dMRI) is a pivotal non-invasive tool for assessing the development of brain connectivity and microstructure. However, the prolonged acquisition times and complex sampling requirements render dMRI highly susceptible to unpredictable fetal motion. Existing motion correction methods typically process each dMRI volume independently and focus on inter-slice motion. Such strategies fail to utilize the coherent information between dMRI volumes along different diffusion directions and lack the ability to restore the intra-slice corruption. To address these limitations, we proposed iFeST, an iterative framework that combines frequency (k-space), spatial, and temporal (inter-slice) modeling for fetal brain dMRI motion correction. At each iteration, iFeST integrates information across diffusion directions into fiber orientation distributions (FODs). These distributions encode local fiber orientations within each voxel and serve as microstructural priors for intra-slice restoration and inter-slice alignment in the next iteration. To train the framework, we developed a fetal brain dMRI motion simulator that synthesizes compound motion artifacts from FODs. Evaluation on simulated datasets demonstrated that iFeST outperformed four inter-slice networks in motion estimation and three intra-slice networks in image restoration. Further validation on a real-world dataset confirmed significantly better volume reconstruction and FOD estimation than conventional pipelines. Overall, iFeST provides a learning-based framework for fetal dMRI motion correction, restoring motion-corrupted data and improving microstructural reconstruction for downstream diagnostic applications.
Figures & tables
Fig. 1: Overview of the proposed iterative MoCo framework iFeST. The framework initializes with Nvol dMRI stacks (a) and a GA-matched FOD atlas (b) for initial reference generation. (c) Sub-network FeST processes individual stacks, yielding intra-slice motion-corrected stacks and inter-slice motion parameters. (d) The SVR module aligns corrected slices to reconstruct an isotropic volume for each stack. (e) Volumes are aggregated to estimate FOD via a pre-trained network. Updated FOD is forward-projected in (f) and mapped to slice space in (g) to generate references for the next iteration. STN: spatial transformer network; SDA: scattered data approximation; FOD: fiber orientation distribution; SH: spherical harmonics.
Fig. 2: Architecture of the FeST network. FeST comprises two parallel branches for intra-slice artifact removal and inter-slice motion estimation. The intra-slice branch takes the raw dMRI stack and a reference input comprising synthesized and previously corrected stacks. It consists of a main stream incorporating spatial-frequency feature fusion (SpaFre) modules, guided by a lightweight reference stream at each stage. Within each SpaFre module, F and S denote frequency- and spatial-domain processing, respectively. The inter-slice branch extracts hierarchical features from both streams. These features are projected into token sequences via convolutional embeddings and processed by four stacked MSA-MCA modules to capture temporal dependencies. MSA: multi-head self-attention; MCA: multi-head cross-attention.
Fig. 3: (a) The spatial-frequency feature fusion (SpaFre) module processes reference and main features in spatial and frequency domains. The spatial path processes concatenated features using residual convolutional blocks. The frequency path applies slice-wise DFT to input features, fuses their amplitude and phase separately, and maps fused features back to the spatial domain using IDFT. (b) Convolutional embedding in the inter-slice branch. Multi-scale feature maps are projected to a unified size ( 6×6 ) using convolutions with kernel sizes and strides of 4×4×1 , 2×2×1 , and 1×1×1 , respectively. Projected features are flattened slice-wise and summed across scales into 20 tokens. (c) Simplified schematics of the MSA and MCA blocks, with individual attention heads omitted. DFT: discrete Fourier transform; IDFT: inverse discrete Fourier transform; MSA: multi-head self-attention; MCA: multi-head cross-attention.
Fig. 4: Illustration of the motion simulation pipeline. (a) The standard EPI sequence for a single 2D slice and simulated motion trajectory. Three motion intervals are shown within the 200-ms window. The trajectory is generated via interpolation of control points (gray dots). The motion state at the effective echo time (denoted by the green star) defines the rigid transformation for inter-slice simulation, while instantaneous states during the readout window (denoted by circles) drive the intra-slice simulation. (b) Inter-slice simulation for a single slice. (c) Intra-slice simulation. The k-space of this slice is synthesized by assembling segments from different motion states. DFT: discrete Fourier transform; IDFT: inverse discrete Fourier transform.
Network
Translation
Rotation
wMAE ↓
r↑
RMSE ↓
wMAE ↓
r↑
RMSE ↓
SVR-Net
1.7153±0.0940
0.7659±0.0347
2.2045±0.1313
3.4031±0.5159
0.9259±0.0390
4.3247±0.7063
DeepPMT
1.1838±0.1381
0.9026±0.0265
1.4357±0.1783
3.5290±0.6939
0.9036±0.0450
4.3990±0.8984
AFFIRM
1.0626±0.1418
0.9195±0.0219
1.3034±0.1794
3.5703±0.6666
0.9047±0.0428
4.4132±0.8174
SVoRT
1.0560±0.1655
0.9231±0.0224
1.2801±0.2107
3.1655±0.7890
0.9207±0.0488
3.9444±0.9973
iFeST
0.9100±0.2135
0.9481±0.0283
1.1234±0.3208
2.5517±0.6472
0.9501±0.0313
3.1333±0.8862
TABLE I: Inter-slice motion estimation on simulated data. Values are reported as mean ± standard deviation. Best values are in bold. Significant differences ( p<0.001 ) are found between iFeST and other networks using paired t-tests.
Fig. 5: Visual comparison of inter-slice motion estimation on the simulated dataset. (a) and (b) present the wMAE for translation and rotation, respectively. The scatter dots represent individual test cases, and asterisks indicate statistically significant differences compared to iFeST (*** p<0.001 , paired t-test). (c) and (d) display the density scatter plots and linear regression analyses of predicted parameters versus GT. The dotted line represents the ideal agreement, while the solid line indicates the linear fit of the predictions. Here, k denotes the slope and r denotes the Pearson correlation coefficient.
Fig. 6: Intra-slice motion-corrected outputs and error maps under three corruption scenarios: (a) severe signal dropout caused by diffusion encoding motion, (b) aliasing and blurring caused by intra-slice motion, and (c) and (d) low-quality images with strong noise.
Network
SSIM ↑
NRMSE ↓
PSNR (dB) ↑
U-Net
0.8630±0.0366
0.0521±0.0063
28.33±0.97
PriorNet
0.8707±0.0357
0.0638±0.0060
26.60±0.56
cGAN
0.7870±0.0527
0.0715±0.0074
25.57±0.91
iFeST
0.8843±0.0368
0.0437±0.0067
29.89±1.17
TABLE II: Intra-slice motion artifact correction on simulated data. Values are reported as mean ± standard deviation. Best values are in bold. Significant differences ( p<0.001 ) are found between iFeST and other networks using paired t-tests.
Inter-Slice Correction
Intra-Slice Correction
dMRI Volume
FOD
SSIM ↑
NRMSE ↓
PSNR (dB) ↑
SH0-SSIM ↑
DWI-SSIM ↑
ACC ↑
SVRTK
SVRTK
0.5823±0.1060
0.1746±0.0330
15.33±1.69
0.7163±0.0790
0.7149±0.0792
0.3156±0.0329
SVR-Net
iFeST
0.6619±0.0937
0.1058±0.0213
19.69±1.73
0.8207±0.0579
0.8013±0.0654
0.4789±0.0327
DeepPMT
0.7054±0.0918
0.0965±0.0218
20.53±1.89
0.8467±0.0614
0.8267±0.0684
0.5367±0.0430
AFFIRM
0.7086±0.0923
0.0978±0.0227
20.42±1.94
0.8414±0.0633
0.8234±0.0695
0.5383±0.0398
SVoRT
0.7149±0.0912
0.0951±0.0207
20.65±1.84
0.8501±0.0610
0.8323±0.0668
0.5546±0.0413
TABLE III: dMRI volume reconstruction and FOD fitting on simulated data. iFeST supplied each single-task network’s complementary correction. Values are reported as mean ± standard deviation. Best values are in bold. Significant differences ( p<0.001 ) are found between iFeST and other methods using paired t-tests.
Fig. 7: Qualitative comparison of dMRI volume reconstruction and FOD fitting on the simulated dataset. The top half shows reconstructed dMRI volumes and error maps. The bottom half presents fitted DEC-FA maps, DEC-FOD maps, and FOD glyphs in the corpus callosum. iFeST best preserved anatomy and white matter orientations, with the lowest residual errors. DEC denotes directionally encoded color.
Method
dMRI Volume
FOD
SSIM ↑
NRMSE ↓
PSNR (dB) ↑
SH0-SSIM ↑
DWI-SSIM ↑
ACC ↑
SVRTK
0.8220±0.0950
0.1073±0.0630
21.70±3.27
0.8278±0.0938
0.8186±0.0978
0.5209±0.0740
iFeST
0.8495±0.0823
0.0903±0.0552
23.26±3.35
0.8606±0.0818
0.8512±0.0857
0.5555±0.0881
TABLE IV: dMRI volume reconstruction and FOD fitting on real-world data. Values are reported as mean ± standard deviation. Significant differences ( p<0.001 ) are found between iFeST and SVRTK using paired t-tests.
Fig. 8: Volume reconstruction and FOD estimation on real-world data. (a) and (b) show DW volumes and zero-order FOD coefficient volumes, respectively, with orthogonal views and error maps. White arrows indicate local distortions and blurred boundaries. (c) shows DEC-FOD maps, FOD profiles, and magnified glyphs. White boxes denote regions near the genu and splenium of the corpus callosum. GT denotes the pseudo-GT reference.
Model Variant
Motion wMAE ↓
Image SSIM ↑
full model (iFeST)
1.7309
0.8843
w/o intra-slice task & iteration
2.2872
–
w/o inter-slice task & iteration
–
0.8710
w/o iteration
2.0301
0.8776
w/o frequency modeling
1.8090
0.8786
w/o slice-wise conv
1.9859
0.8651
TABLE V: The ablation results for iFeST and its variants on the simulated dataset.
Magnetic resonance imaging (MRI) is highly susceptible to patient motion due to its relatively long acquisition times and the fact that data are acquired sequentially in k-space. Even small patient movements introduce phase inconsistencies across measurements, leading to severe artifacts such as blurring, ghosting, and geometric distortions that can compromise diagnostic quality. Retrospective motion compensation remains challenging, particularly in accelerated acquisitions, due to the ill-posed nature of the joint reconstruction and motion estimation problem. In this work, we propose a unified Bayesian framework for motion-compensated 3D MRI that jointly estimates the anatomical image, rigid-body motion parameters, and coil sensitivity maps directly from motion-corrupted k-space data. Our approach integrates pretrained 3D complex-valued score-based diffusion models as expressive anatomical image priors within a physics-based forward model. Inference is performed by alternating diffusion posterior image updates with efficient proximal optimization steps for motion and coil sensitivity estimation, enabling fully unsupervised reconstruction without the need for paired motion-free training data. Experiments on simulated and real-motion brain MRI datasets demonstrate that the proposed method achieves improved image quality and motion robustness compared to state-of-the-art classical and learning-based motion correction techniques, particularly in the presence of severe motion and high acceleration.
Antonio Ortiz-Gonzalez, Erich Kobler, Lukas Schletter +1
Life and Medical Sciences Institute, University of Bonn, Bonn, Germany · Institute for Machine Learning, LIT AI Lab, Department of Virtual Morphology, Clinical Research Institute Medical AI, Johannes Kepler University Linz, Linz, Austria · German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany +1
Diffusion MRI (dMRI) relies on diffusion-weighted echo-planar imaging, which is highly susceptible to eddy-current-induced geometric distortions. These distortions vary across diffusion volumes according to gradient strength and direction, causing between-volume misalignment that can bias downstream microstructural analyses. Current state-of-the-art correction methods, such as FSL Eddy, achieve high-quality correction through iterative prediction-correction schemes but are computationally expensive. We propose Eddeep, a deep-learning framework for fast eddy-current distortion correction in dMRI. Eddeep decomposes the problem into two stages. First, a supervised image translation network standardises the appearance of diffusion-weighted and b=0 images, removing contrast differences that hinder reliable registration. Second, an unsupervised registration network estimates both eddy-current distortion and between-volume head motion parameters under a physics-constrained quadratic distortion model, enabling correction in a single forward pass. The method was trained on UK Biobank data and evaluated on both in-domain (UK Biobank) and out-of-domain (Memodyn) datasets. Across a range of complementary metrics, including between-volume jitter, diffusion kurtosis imaging residuals, signal irregularity, and mutual information, Eddeep achieved correction quality comparable to that of FSL Eddy while substantially reducing inference time. These results demonstrate that deep learning can provide accurate and efficient eddy-current distortion correction without relying on iterative optimisation, supporting the development of faster diffusion MRI processing pipelines for large-scale studies and clinical deployment. The code is available at: https://github.com/CIG-UCL/eddeep.
Antoine Legouhy, Ross Callaghan, Yuchuan Qiao +4
Hawkes Institute & Department of Computer Science, University College London, London, UK · Institut Pasteur, Universit´e Paris Cit´e, Unit´e de Neuroanatomie Appliqu´ee et Th´eorique, France · AINOSTICS ltd., Manchester, UK +3
Diffusion MRI (dMRI) probes water diffusion within the brain, providing unique information about tissue microstructure and white matter connectivity. High-quality dMRI enables advanced and accurate analyses but demands dense acquisitions, resulting in long scan times and hardware constraints that are often infeasible. Further, dMRI requires dedicated computational methods to support diverse analysis tasks (e.g., parcellation, registration, and synthesis) for both neuroscientific and clinical applications. Here, we present dMRI-F, a foundation model that unifies dMRI data enhancement and downstream tasks across diverse acquisitions and populations, while requiring only minimal acquisition input. dMRI-F is pre-trained with a q-space masked reconstruction task: predicting densely sampled multi-shell data from only six volumes. It learns generalizable latent feature representations of dMRI data, which serve as a core foundation for adapting to diverse downstream tasks, including brain parcellation, brain registration, and cross-modal synthesis. Across nine independently acquired datasets, we demonstrate that dMRI-F outperforms state-of-the-art methods with robust generalization across acquisitions, populations, and tasks. Our results demonstrate dMRI-F's versatility as a general-purpose framework that enables diverse dMRI applications from low-cost, sparse acquisitions.
Xi Zhu, Yijie Li, Xiaofan Wang +4
University of Electronic Science and Technology of China.