Success-rate gains guide the development of web agents. Yet knowing which agent ranks first does not tell us how much confidence to place in its reported advantage. We study the comparison itself: how success is defined, what evidence supports the judgments, and how the difference between agents is estimated. On fixed web-agent executions, changing a judge from predicting likely completion to requiring recorded support can remove most of a reported lead without changing the ranking. This effect persists when unresolved completion is distinguished from supported failure. Controlled source additions explain how missing relations between task requirements, objects and observations can conceal a difference or create an apparent advantage. We also find that making both agents' score estimates more accurate can make their difference less accurate, because their original errors partly canceled. To estimate a chosen outcome difference, we combine judge predictions with reference labels for sampled task pairs. Across four released execution systems, regression fitted on the same 50 labeled pairs reduces estimation error relative to direct paired sampling. The results give agent researchers a practical basis for assessing claimed improvements: make the comparison target explicit, retain the evidence needed to check it, and use paired labels to estimate the difference directly.
Figures & tables
Figure 1. Three complementary checks of an agent comparison. (a) Astra judges the same full trace and final screenshot under two success rules. (b) Archived task relations reveal a positional distinction and remove an apparent purchase advantage; browser cards illustrate record contents. Checks denote success endorsement; crosses denote non-endorsement. (c) Full-cohort judge differences and 50 paired reference labels yield a regression-adjusted estimate. A judge value of 0.5 averages two disagreeing calls. Strips show task excerpts; the scatter illustrates one sample, while the bars summarize repeated-sampling MSE across ten human-reference settings. Three complementary studies show rule-dependent endorsement gaps, local effects of adding layout or product records, and paired regression that combines full-cohort judge outputs with 50 reference pairs.
Qwen rate
Claude rate
Claude lead
Lead reduction
Judge
View
P
Ct
P
Ct
P
Ct
Estimate [95% CI]
Astra
Final
18.33
13.17
26.67
14.50
8.33
1.33
7.00 [3.67, 10.50]
Astra
Expanded
19.33
14.67
26.33
18.00
7.00
3.33
3.67 [0.50, 7.00]
Sonnet 4.5
Final
25.17
17.00
31.17
21.83
6.00
4.83
1.17 [ − 2.33, 4.83]
Sonnet 4.5
Expanded
23.33
17.17
30.50
21.00
7.17
3.83
3.33 [0.17, 6.67]
Kimi K2.5
Final
23.00
17.17
32.50
24.67
9.50
7.50
2.00 [ − 1.17, 5.33]
Table 1. Judgments on the same 300 task pairs. P: prediction; Ct: certification. Rates are percentages; leads and lead reductions are percentage points. Each row reports a 95% interval for the lead reduction.
Supported
Supported
System
success
failure
Unresolved
Qwen
13.0
74.3
12.7
Claude
14.3
62.5
23.2
Table 2. Three-state judgments with Astra/final. Rates (%) use the full denominator. Similar supported-success rates coexist with different failure and uncertainty rates.
Figure 2. Certification lowers the systems’ scores by different amounts. Each point is a system’s prediction-minus-certification rate, with a 95% interval. The difference between two systems’ reductions is the change in their lead. GPT denotes GPT-4o; the two task cohorts overlap. Two panels show rule-dependent score reductions for Qwen, Claude and GPT on 300 tasks and for those systems plus Llama on 206 tasks. Astra and Sonnet produce different patterns of reductions.
Evidence supplied
P
Ct
Grid position
Original record
(1,1)
(0,0)
Add position–product–destination relation
(0,1)
(0,1)
Laptop purchase
Record + button mapping
(0,1)
(0,0)
Add product identity
(1,1)
(0,0)
Table 3. Source additions change local comparisons. Entries are (Qwen, Claude) success endorsements under prediction (P) and certification (Ct); both repetitions agree. Full controls are in the supplement.
Estimated quantity
Before calibration
After calibration
Qwen rate
−6.50
−1.52
Claude rate
−5.83
+5.37
Claude–Qwen lead
+0.67
+6.89
Table 4. Closer scores, a worse lead estimate. Signed errors for Astra/final certification against the functional reference (percentage points); positive means overestimation.
Figure 3. More informative comparisons from the same 50 labeled task pairs, using the human reference. (a) MSE reductions relative to direct paired sampling: blue circles show regression and gray diamonds show equal-weight correction. Positive values indicate lower error. (b) How often regression’s approximate 95% interval identifies the reference leader; the dashed line marks direct sampling. Full numerical results and coverage are in Supplement V. Ten settings grouped by judge share row labels. The left panel compares regression and equal-weight MSE reductions against direct paired sampling. The right panel shows regression intervals identifying the reference leader, with direct sampling as a common baseline.