Three-dimensional (3D) ultrasound provides valuable volumetric context for anatomical assessment, motivating reconstruction from widely available two-dimensional (2D) slices. Sparse slices leave much of the volume unobserved, even when their acquisition poses are known. Existing methods interpolate observed intensities or incorporate learned 2D image features into 3D reconstruction, but their complementary roles in predicting smooth structure and residual details remain less explored. We introduce XFreq, a geometry-aligned framework for sparse 3D ultrasound reconstruction. It uses known slice poses and finite footprints to query 2D image features at 3D locations, complementing splatted intensities and sampling geometry. A low-frequency decoder predicts a smooth 3D field from the splat representation, while a high-frequency decoder additionally incorporates the queried 2D features to predict residual details. A learned gating module regulates the residual contribution based on geometry and cross-slice feature variation. We evaluate XFreq on an in-house fetal brain dataset and the public CETUS cardiac dataset, using slices resampled from 3D ultrasound volumes and fivefold cross-validation. Among the compared methods, XFreq achieves the highest PSNR and SSIM in most settings across both datasets, reaching 26.82 dB PSNR on CETUS with 32 input slices. Ablation studies further show the contributions of local feature querying, geometric cues, and residual prediction, with gains generally increasing as more input slices are used. Our findings highlight the value of geometry-aligned cross-view feature integration for reconstructing 3D ultrasound volumes from sparse 2D slices.
Figures & tables
Figure 1: Sparse observations and cross-view feature querying.
Figure 2: XFreq architecture. Splatted intensities and pose geometry supply shared 3D features to both decoders. Geometry aligned queries aggregate 2D features for the high frequency residual and feature variance for the gate. Data consistency is applied after prediction.
Method
FetalBrain
CETUS
N=8
N=16
N=32
N=8
N=16
N=32
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
Classical Methods
Interpolation
13.66 ± .194
0.386 ± .011
14.56 ± .176
0.542 ± .005
15.42 ± .140
0.697 ± .007
17.98 ± .385
0.530 ± .009
19.48 ± .458
0.653 ± .012
20.62 ± .518
0.760 ± .012
Harmonic
15.17 ± .203
0.417 ± .010
16.27 ± .174
0.580 ± .003
17.42 ± .126
0.733 ± .006
19.84 ± .376
0.594 ± .015
21.69 ± .469
0.717 ± .014
23.25 ± .542
0.810 ± .012
NConv [ 20 ]
15.41 ± .193
0.434 ± .009
16.38 ± .150
0.586 ± .003
17.41 ± .120
0.722 ± .008
20.07 ± .357
0.594 ± .011
21.59 ± .436
0.711 ± .012
22.92 ± .496
0.801 ± .011
Table 1: Comparison of reconstruction methods on FetalBrain and CETUS . Unobserved foreground PSNR (dB) and 3D SSIM are reported as mean ± standard deviation across five patient folds. N denotes the number of input slices. For supervised methods, indented rows labeled “w/o DC” report predictions without the shared data consistency correction.
Figure 3: Qualitative comparison of 3D ultrasound reconstruction. (a) Reconstruction results on FetalBrain and CETUS with 8 and 32 input slices. (b) Enlarged regions comparing reconstruction details and absolute errors.
Configuration
FetalBrain
CETUS
N=8
N=16
N=32
N=8
N=16
N=32
Δ PSNR ↑
Δ SSIM ↑
Δ PSNR ↑
Δ SSIM ↑
Δ PSNR ↑
Δ SSIM ↑
Δ PSNR ↑
Δ SSIM ↑
Δ PSNR ↑
Δ SSIM ↑
Δ PSNR ↑
Δ SSIM ↑
Branches and Fusion
w/o G⊙H
+1.05 ± .187
+0.107 ± .008
+1.70 ± .165
+0.112 ± .004
+2.36 ± .161
+0.091 ± .009
+0.82 ± .152
+0.042 ± .005
+1.52 ± .266
+0.046 ± .006
+2.26 ± .424
+0.041 ± .007
w/o G
+0.02 ± .070
+0.002 ± .004
+0.05 ± .063
+0.003 ± .004
+0.04 ± .077
+0.002 ± .002
+0.08 ± .015
+0.002 ± .001
+0.07 ± .053
+0.001 ± .001
+0.09 ± .058
+0.001 ± .001
Queried Image Features
Table 2: Ablation studies. We consider three aspects of XFreq: reconstruction branches and fusion, queried image features, and geometry design. Δ denotes XFreq minus the corresponding ablation variant.
Figure 4: Spatial distribution of PSNR gains from queried image features. Curves show the mean Δ PSNR (dB) of XFreq over the w/o Queried Features variant, while colored labels indicate the corresponding standard deviations across five patient folds.
We present UltraVoxelGS, a 3D ultrasound reconstruction method that achieves both fast reconstruction and physically faithful rendering for the first time, bringing live spatial feedback during 2D ultrasound scanning within reach. This is made possible by a feed-forward design that predicts a complete Gaussian scene representation from posed ultrasound images directly, entirely bypassing the per-scene optimization bottleneck that has confined prior methods to offline use. Realising such feed-forward prediction in this setting is non-trivial: unlike natural images, ultrasound slices share at most one-dimensional intersections and exhibit view-dependent appearance due to acoustic propagation and attenuation, violating the dense overlap and photometric consistency assumed by existing feed-forward Gaussian methods. Hence, to achieve fast reconstruction, we introduce a feed-forward voxel-to-Gaussian pass that decouples representation size from input count by lifting all posed slices into a fixed-size voxel support and predicting Gaussian parameters directly. For faithful rendering, we propose ultrasound-aware appearance rendering strategy factorize reflection from cumulative attenuation during training and exploit appearance continuity among spatially adjacent slices for efficient Render-time Appearance Adaptation. On both real-world and simulated datasets, UltraVoxelGS achieves best PSNR/SSIM compared with per-scene optimization baselines while reducing inference from 10-20 minutes to approximately 10 seconds (over 35 times faster) and scales to sequences exceeding 1,000 frames. Code is available at https://github.com/YuebyYue/UltraVoxelGS-camera-ready.
Yue Wang, Haoxin Chen, Xiaoqing Guo
Department of Computer Science, Hong Kong Baptist University, Hong Kong SAR, China
Ultrasound imaging increasingly targets portable, point-of-care, and wearable settings where constraints on power, bandwidth, and hardware complexity often necessitate sparse data acquisition in spatiotemporal scanning. However, image reconstruction using the sparse data can introduce insufficient phase information in coherent beamforming process, resulting in grating-lobe artifacts that degrade imaging contrast resolution. We present a physics-guided, data-driven framework for sparse-to-dense radio-frequency (RF) reconstruction that aligns training with downstream image formation. Our approach trains an end-to-end interpolation network using a hybrid supervision scheme that combines an RF-domain and a beamforming-domain loss with exponential moving average (EMA) to stabilize the multi-objective training. To improve generalization under variable acquisition layouts, we also introduce a random-skip masking strategy that varies sparsity patterns during training so a single model can handle diverse decimation factors and irregular channel configurations. We evaluate the framework on a held-out test set using the mean structural similarity index measure (SSIM) between reconstructed and ground-truth beamformed images. Across decimation factors ×2 to ×13, the best-performing configuration maintains mean SSIM around 0.95. Overall, the results show consistent gains in RF reconstruction and post-beamforming image quality across diverse acquisition conditions. This approach enables robust, high-quality ultrasound imaging at resource-constrained settings by allowing more sparse scanning in spatiotemporal domain.
Luoyuan Zhang, Yiyang You, Ananya Tandri +4
University of North Carolina at Chapel Hill, Chapel Hill, NC, USA · Johns Hopkins University, Baltimore, MD, USA
Wide Field-of-View (WFoV) reconstruction enhances 3D ultrasound imaging by providing valuable anatomical context for segmentation models and visualization. Clinical ultrasound volumes are predominantly acquired using convex probes, which generate expanding, diverging acoustic beams to maximize anatomical coverage. Stitching these sweeps together traditionally introduces significant compounding artifacts and aliasing due to depth-dependent resolution changes. Here, we introduce Ultra-Wide-NeRF, a Multivariate 3D Gaussian (MVG) NeRF-based method for WFoV ultrasound reconstruction. By explicitly modeling the complex beam geometry using distance-dependent convex volumetric sampling and anisotropic 3D Gaussians, our method inherently mitigates these compounding artifacts and provides anti-aliasing. Beyond simply reconstructing a static 3D grid, our NeRF-based approach yields a continuous neural representation of the tissue, enabling the synthesis of high-fidelity novel views from arbitrary virtual trajectories. We validate Ultra-Wide-NeRF for intracardiac echocardiography on phantom and porcine datasets, demonstrating that our method expands the spatial context important in intraoperative navigation. Code will be open-sourced upon publication.
Patris Valera, Magdalena Wysocki, Felix Duelmer +4
Chair for Computer Aided Medical Procedures (CAMP), Technical University of Munich, Germany · Munich Center for Machine Learning (MCML), Munich, Germany · LUMA Vision, Beech Hill Road, Dublin, Ireland