cs.LGNov 23, 2026

Layer-Readout Interfaces in EEG Foundation Models: Predictive Accessibility and Cross-Dataset Transfer

Authors: Yanlin Fu, Wei Liu, Liming Zhao

Organizations: QMindTech, Shanghai, China

Abstract

Intermediate layers often outperform final layers when foundation models are used as frozen feature extractors, but the source of this advantage is unclear. We study this question in EEG foundation models by separating three factors: how representations are read out, whether intermediate layers provide predictive utility beyond the final-layer interface, and whether useful depth structure transfers across datasets. Across five models and three tasks, improving the final-layer readout consistently recovers substantial predictive performance, yet intermediate layers remain advantageous within frozen extraction. We also find that layers selected on one dataset remain useful on another across five dataset pairs and four task families, and that a compact set of source-derived task directions retains predictive value after transfer in sleep staging. Together, these results show that predictive utility varies across depth, and its usefulness depends on how representations are read out and transferred. More crucially, source-selected layers provide a reusable feature interface across datasets, reducing the need for target-side layer search while outperforming final-layer baselines on target datasets.

Figures & tables

Appendix figures & tables29 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 12, 2026

What Do EEG Foundation Models Capture from Human Brain Signals?

Clinical electroencephalogram (EEG) analysis rests on a hand-crafted feature catalog refined over decades, e.g., band power, connectivity, complexity, and more. Modern EEG foundation models bypass this catalog, learn directly from raw signals via self-supervised pretraining, and match or outperform feature-engineered baselines on most clinical benchmarks. Whether the two representations align is an open question, which we decompose into three sub-questions: what does the model learn, what does the model use, and how much can be explained. We answer them with layer-wise ridge probing, LEACE-style cross-covariance subspace erasure, and a transparent classifier benchmarked against a random-feature baseline. The audit covers three foundation models (CSBrain, CBraMod, LaBraM), five clinical tasks (MDD, Stress, ISRUC-Sleep, TUSL, Siena), and a 6-family 63-feature lexicon. Of the 945945 (model, task, feature) units, 648648 (68.6%68.6\%) are representation-causal and 199199 (21.1%21.1\%) are encoded-only. Across tasks, 5050 features qualify as universal candidates with strong support (all three architectures RC) in two or more tasks. Frequency-domain features dominate, but the other five families each contribute substantial causal mass. Confirmed features recover, on average, 79.3%79.3\% of the foundation model's advantage over the random baseline, with a clean task gradient (MDD ≈0.99\approx 0.99 down to Stress ≈0.56\approx 0.56): tasks near ceiling are almost fully recovered by the lexicon, while harder tasks leave a non-trivial residual that pinpoints a concrete target for future concept discovery.
Jul 31, 2026

EEG-JEPA: Structured Latent Prediction for EEG Foundation Models

Electroencephalography (EEG) foundation models aim to learn reusable representations from large-scale unlabeled recordings. A common pretraining strategy is masked waveform reconstruction, but applying supervision directly to noisy EEG may encourage models to recover predictable background activity, acquisition effects, and artifacts rather than neural structure that transfers across tasks. This raises a central question: what should an EEG foundation model predict to learn transferable representations? We introduce EEG-JEPA a structured latent-prediction framework for EEG foundation modeling. Rather than reconstructing masked voltage samples, a masked context encoder and predictor infer contextual latent states produced by an exponential-moving-average target encoder that observes the complete input. EEG-JEPA organizes target design along three complementary dimensions: target content specifies what representation is predicted, target support specifies where prediction occurs over structured electrode--time regions through Neurotopology-Aware Multi-scale Electrode-Temporal Masking (N-MET), and target depth specifies at which encoder layers supervision is applied. Together, these designs shift EEG pretraining from recovering missing measurements to inferring latent states from structured electrode--time context. We evaluate EEG-JEPA through controlled objective comparisons, frozen multitask transfer, and full fine-tuning. Under the same backbone, pretraining corpus, and training duration, EEG-JEPA improves the 14-task frozen macro balanced accuracy from 40.49% to 50.42% over CBraMod-style masked waveform reconstruction. Multi-source continuation further raises this result to 52.94%, the highest average among the EEG foundation models evaluated on EEG-FM-Bench. Under protocol-matched full fine-tuning, EEG-JEPA also improves the nine-task average balanced accuracy from 68.98% to 70.65%.
May 27, 2026

A Multi-dimensional Framework for Evaluating Generalization in EEG Foundation Models

Evaluating foundation models under appropriate adaptation settings is essential for understanding the quality and transferability of the learned representations. Recent EEG foundation models have demonstrated promising transfer capabilities across tasks and datasets, motivating their growing use in neurotechnology and clinical applications. However, these models are typically evaluated under full fine-tuning on well-curated downstream datasets, a setting that does not reflect biomedical domain constraints such as limited labeled data, reduced sensor coverage, or parameter-efficient adaptation. In this work, we propose a multi-dimensional evaluation framework for assessing EEG models under realistic low-resource conditions. Empirical analysis of both supervised EEG models and recent EEG foundation models, including LaBraM, CSBrain, and CBraMod, across 6 different datasets is performed under the proposed multi-dimensional evaluation framework. We find that EEG foundation models consistently provide performance gains on long-context tasks such as sleep stage prediction and mental health state classification. In contrast, for short-window Brain Computer Interface style tasks, supervised models achieve comparable despite having substantially fewer parameters. Additional analyses demonstrate that current foundation models provide limited robustness to short-window tasks and channel constrained settings. Together, these findings motivate the use of multi-dimensional evaluation protocols that characterize model behavior under realistic use constraints.