eess.IVNov 23, 2026

Exact Volume-Preserving Diffeomorphic Shear Splitting: Continuous-Discrete Geometric Bounds, Reversible Memory Backpropagation, and Expressivity Frontiers in Volumetric Mapping

Authors: Alvaro Garcia-Casas

Organizations: Department of Bioengineering, Universidad Carlos III de Madrid, Avenida de la Universidad 30, 28911 Leganés (Madrid), Spain

Abstract

Incompressible diffeomorphic registration requires continuous spatial mappings that preserve local tissue volume (det(DΦ) = 1) without topological folding (det(DΦ) > 0). Standard velocity-field methods (SVF, LDDMM) approximate incompressibility via numerical ODE integration or soft penalties, exhibiting numerical volume drift (~10^-4 to 10^-1), iterative grid inversions, and linear backpropagation memory O(L * N_vox). We formulate an exact structure-preserving framework for 3D registration based on cascaded coordinate shears. By decomposing the divergence-free Lie algebra sdiff(Ω) into six coordinate-shear generators whose convective non-linearities vanish identically, each elementary stage integrates analytically to a closed-form triangular shear with det(DS_k) = 1 and exact machine-precision inverse requiring zero iterations and zero spatial interpolations. Multi-stage compositions generate the connected volume-preserving group SDiff_0(Ω). We establish: (i) an unconditional global diffeomorphism proof closing the Hadamard-Caccioppoli injectivity gap; (ii) a Dirichlet boundary confinement lemma; (iii) an anisotropic Riemannian similarity invariance; (iv) a Sobolev H^2 spectral budget preventing chaotic mixing; and (v) an exact reversible backpropagation engine eliminating O(L) trajectory storage (0.00 MB intermediate activations). We prove second-order O(h^2) sub-voxel convergence across 16^3 to 64^3 lattices and second-order trajectory accuracy for palindromic Strang splitting (468.1x error reduction vs. Lie-Trotter; drift |det(DΦ)-1| <= 2.22e-16). Execution is 2.1x-4.0x faster than SVF with 78.4% GPU memory reduction. On cardiac cine-MRI (ACDC, N=100) and brain MRI (OASIS-1, N=414), our model achieves competitive Dice (0.884 and 0.841) while strictly maintaining 0.0000% folding and zero volume drift.

Figures & tables

Explore similar work

Sep 9, 2026

Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration

Diffeomorphic image registration is central to medical image analysis, enabling anatomically consistent alignment across subjects. Most learning-based diffeomorphic methods model autonomous ODEs(ordinary differential equations) by parameterizing a stationary velocity field and recovering deformations via scaling-and-squaring. While non-autonomous ODEs with time-dependent velocities increase expressiveness, existing approaches rely on numerical integration to implicitly enforce flow structure that entangles model expressiveness with discretization accuracy. We propose a framework to directly learn the continuous-time solution of a non-autonomous ODE formulated as a two-parameterflow map. By enforcing cocycle consistency, a fundamental structural property of time-varying flows, we learn the flow maps without time discretization and velocity integration during training. The framework recovers diffeomorphic mappings at inference using a small number of compositions. Our proposed framework seamlessly incorporates standard registration backbones and improves alignment accuracy consistently across nine datasets while preserving diffeomorphic structure. Notably, the proposed method achieves an average Dice improvement of 2.1% on brain MRI benchmarks, a 12% TRE reduction on lung CT, and a 2.6% Dice gain on cardiac MRI and ultrasound datasets.
Mar 17, 2026

Volumetrically Consistent Implicit Atlas Learning via Neural Diffeomorphic Flow for Placenta MRI

Establishing dense volumetric correspondences across anatomical shapes is essential for group-level analysis but remains challenging for implicit neural representations. Most existing implicit registration methods rely on supervision near the zero-level set and thus capture only surface correspondences, leaving interior deformations under-constrained. We introduce a volumetrically consistent implicit model that couples reconstruction of signed distance functions (SDFs) with neural diffeomorphic flow to learn a shared canonical template of the placenta. Volumetric regularization, including Jacobian-determinant and biharmonic penalties, suppresses local folding and promotes globally coherent deformations. In the motivating application to placenta MRI, our formulation jointly reconstructs individual placentas, aligns them to a population-derived implicit template, and enables voxel-wise intensity mapping in a unified canonical space. Experiments on in-vivo placenta MRI scans demonstrate improved geometric fidelity and volumetric alignment over surface-based implicit baseline methods, yielding anatomically interpretable and topologically consistent flattening suitable for group analysis.
Sep 21, 2026

GraphSVR: q-Space--Aware Graph-Based Slice-to-Volume Registration for Diffusion MRI

Diffusion-weighted imaging (DWI) remains highly vulnerable to subject motion, particularly in time-efficient protocols and in motion-prone populations. While slice-to-volume registration (SVR) can mitigate inter-slice and inter-stack misalignment, diffusion MRI introduces additional complexity due to diffusion-direction-dependent contrast and the requirement to align dozens of measurements within a common reference frame, effectively yielding a 4D registration problem. Existing approaches rely primarily on sequential modeling or pairwise similarity and often degrade under sparse gradient sampling or severe motion. We introduce GraphSVR, a q-space-aware graph-based framework for 4D SVR registration in DWI. GraphSVR represents slice groups as nodes in an acquisition-structured graph, with edges encoding temporal proximity, spatial slice geometry and diffusion encoding relationships. A graph neural network predicts globally consistent stack-wise rigid motion, optimized in a self-supervised, zero-shot manner using only an anatomical reference image, without requiring paired ground-truth motion. We evaluate GraphSVR using both fully synthetic diffusion simulations and realistic recombination-based simulations from real acquisitions with controllable motion severity and gradient sparsity. Performance is quantified using grid error (mm) and rotation error relative to known ground-truth transforms. Under severe motion, GraphSVR reduces grid error and rotation error by 73% compared to FSL eddy, the standard DWI motion-correction method, with the largest gains observed in sparse-direction regimes. These results demonstrate that explicitly modeling acquisition structure through graph-based reasoning improves robustness and global consistency in 4D DWI motion estimation. Code is available at https://github.com/nogakertes/GraphSVR.git.