cs.LGNov 23, 2026

Is 4 Bits Enough for EEG Sleep Staging? A Subject-Level Benchmark of MXFP4, NVFP4 and FP8

Authors: Emese Batizi, Hossein Valavi

Organizations: Princeton University, Princeton, NJ, USA

Abstract

Staging sleep on a wearable device keeps the raw electroencephalogram (EEG) private and saves the energy needed to transmit it. It also requires small, energy-efficient neural networks. We benchmark 13 post-training quantization (PTQ) configurations, from FP16 to the block-scaled 4-bit formats MXFP4 and NVFP4, for five-stage sleep staging from single-channel Fpz-Cz EEG. We use Sleep-EDF-78 (78 subjects), subject-wise cross-validation, three training seeds, value-exact emulation, and per-subject paired statistics. All 8- and 16-bit formats stay within 0.45 percentage points (pp) of FP32 Macro-F1. With 4-bit weights and activations, an epoch-wise CNN loses 1.98 to 3.04 pp, and a temporal-context network loses at most 1.19 pp. A same-encoder ablation shows that temporal context explains little of this gap. At equal block size, NVFP4 outperforms MXFP4. The first layer, which quantizes the raw EEG, is the most sensitive layer in both networks. Keeping the first and last layers in FP8 brings both tested 4-bit formats within 0.48 pp of FP32. This recipe adds at most 2.1% weight storage, needs no retraining, and is equivalent to quantization-aware training (QAT) within an exploratory 1-pp margin. The 4-bit losses fall on the same subjects across architectures (Spearman correlation coefficient = 0.69 to 0.79), and they reduce N3 recall the most. On the nested Sleep-EDF-20 subset, NVFP4 with FP8 first and last layers again stays within 0.25 pp of FP32. Under MXFP4, however, the ranking of the architectures reverses, and FP8 first and last layers do not fully recover two of the three tested models. In our emulation, NVFP4 with FP8 first and last layers thus loses little accuracy without QAT in both cohorts.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 6, 2026

Lightweight ML-Based Automatic Sleep Staging Framework with Constrained CNN and Mamba for Small-Sample EEG Datasets

Automatic sleep staging is a key technology for precise diagnosis and treatment of sleep disorders as well as long-term home sleep monitoring. Portable electroencephalogram (EEG) devices have become the focus of research due to their convenience in data collection. However, current methods still face three major challenges: large parameter sizes that easily lead to overfitting on small datasets, low accuracy in classifying difficult stages such as N1 and REM, unclear optimal training dataset size, and difficulty in deployment. This paper proposes GamSleepNet, a lightweight and low-latency automatic sleep staging framework for single-channel EEG. The framework features the FEB module, which combines improved Gabor kernels with learnable filters for feature extraction, uses the Mamba architecture to build a temporal classification network, introduces a novel contrastive loss and a two-stage training strategy, and experimentally validates the optimal dataset size for single-channel EEG sleep staging models. On the Sleepedf dataset, this model achieves an overall accuracy of 87.86 percent with only 30.86 thousand parameters, with all metrics reaching SOTA levels and significantly improving the identification accuracy of challenging sleep stages.
Aug 14, 2026

Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction

Automatic sleep staging from polysomnography (PSG) is a well-studied task, but PSG itself is expensive, clinic-based, and burdensome to manually score, which limits its use for long-term or at-home monitoring. Most existing sleep-staging foundation models are evaluated using the full PSG montage. We instead ask how much of that montage is actually necessary. We evaluate six sleep staging models on the Multi-Ethnic Study of Atherosclerosis (MESA) PSG dataset across three signal conditions: electroencephalography (EEG), electrocardiography (ECG), and their combination (EEG+ECG). This is motivated by edge-cloud deployment, where EEG requires a clinic-grade scalp electrode, whereas ECG is already captured by consumer wearables. We test state-of-the-art foundation models such as SleepFM with an encoder trained from scratch on MESA, alongside BIOT, MOMENT, LaBraM, a base-scale Vision Transformer (ViT-B) reimplementation of SensorLM trained from scratch, and YASA, spanning EEG-pretrained, general-time-series, from-scratch, and classical non-learned approaches. No model architecture is modified from its original form; SensorLM's encoder is reimplemented only in PyTorch. For EEG-only staging, BIOT achieves the best result with a macroF1 of 0.7237, followed by LaBraM (0.6835) and SleepFM from scratch (0.6582). Across the five models capable of ECG-only staging, switching from EEG to ECG costs between 0.2798 (MOMENT) and 0.4151 (BIOT) macroF1, averaging 0.3531, while cutting the raw channel data rate to a third. Adding ECG to EEG provides no gain for most models. These results show that EEG carries most of the sleep-staging signal, quantify the consistent accuracy cost of the wearable-compatible alternative, and demonstrate that sleep-relevant pretraining transfers well to MESA.
Aug 19, 2026

NanoSleep: A Parameter-Efficient Hybrid Temporal Convolutional Network for Single-Channel Sleep Stage Classification

Sleep stage classification from single-channel electroencephalography (EEG) is essential for wearable and home-based sleep monitoring. However, many deep learning models achieve high accuracy at the cost of large model sizes, which limits their deployment on resource-constrained devices. In this work, we present NanoSleep, a compact hybrid temporal convolutional network for automatic sleep stage classification. NanoSleep combines a learnable Sinc-convolutional front end, a dual-branch feature extractor that fuses multi-scale temporal and spectral representations, a gated dilated temporal convolutional backbone with channel recalibration, and a conditional random field for sequence-level decoding. We further employ a weighted calibrated focal loss to address class imbalance. We evaluate NanoSleep on the Sleep-EDF and Sleep-EDF-Expanded datasets using subject-wise cross-validation. The proposed model consistently outperforms six representative baseline methods, and an ablation study confirms the contribution of each major component. These results demonstrate that NanoSleep provides an effective balance between accuracy and efficiency, making it well suited for wearable devices, home-based sleep monitoring, and resource-constrained clinical applications.