EEG-World: Context-Conditioned Dynamics of the Watching Brain
Authors: Junxiang Zhang, Jiayu Zuo, Wenhao Ye, Junfeng Xia, Xiang Chen, Mo Wang, Quanying Liu
Organizations: Southern University of Science and Technology, Shenzhen, China · Shenzhen Loop Area Institute, Shenzhen, China · Shenzhen University, Shenzhen, China · Omni Intelligence, Shenzhen, China · The University of Warwick, Coventry, UK
Brain encoding models predict neural responses from audiovisual input, but typically overlook how ongoing brain activity shapes an individual's response. We introduce EEG-World, a recurrent world model that forecasts 10 seconds of EEG band-power dynamics from 6 seconds of preceding EEG and the subsequent audiovisual stimulus. Pretrained on continuous EEG, EEG-World learns shared neural dynamics and adapts to unseen individuals through lightweight subject-specific readouts. Using 2,584 hours of EEG from 78 participants, we show that nonlinear recurrent forecasting surpasses strong history-aware linear baselines at scale. EEG-World achieves a forecasting correlation of 0.261 versus 0.233 for the strongest history-and-video linear model, with a 3.3-second forecasting-horizon advantage. Its learned dynamics transfer to unseen participants, outperforming the linear baseline in 23 of 24 individuals after calibration. While ongoing EEG history accounts for most predictive performance, controlled stimulus analyses reveal an additional video-dependent component. This component also enables evaluation of visual representations, with V-JEPA 2 improving clip-locked prediction by 35% over combined CLIP and DINOv2 features. Our results demonstrate the value of transferable neural dynamics for individual EEG forecasting and highlight the importance of separating state-driven from stimulus-driven predictability.
Figures & tables
Figure 1: Same clip, different viewers. Different subjects start the same clip in different brain states (left). EEG-World rolls each viewer’s state forward under the clip and forecasts that viewer’s own response (right); a context-free encoding model predicts the same trajectory for everyone (dashed). Traces are drawn from the forecast band power.
Figure 2: Scale against public EEG datasets recorded during audio-visual stimuli. Hours of EEG while a stimulus is on screen, summed over subjects; bubble area shows hours per subject.
Subset
Subjects
Hours
Use
Full corpus
78
2,584
–
AVE presentations
70
1,016
video-paired trials
Continuous pool
70 ‡
2,012
pretraining, scaling
Core subjects
15
908 †
scaling, video, ID
Unseen subjects
24
516
one-shot transfer
Video fine-tuning
65 ‡
630
226,979 clip viewings
Table 1: VAEEG and the subsets used. † Training sessions only. ‡ Includes the unseen subjects’ training data; the models of Sec. 6.3 never see them. Test data never enter training.
Figure 3: EEG-World. One GRU step per second. In the context, the encoded band power e(xt) updates the latent state; in the rollout a learned blank b replaces it ( Eq. 1 ). The clip acts through the video pathway g on frozen features, and a shared readout W plus a per-subject head (Ui,ci) give the forecast. Right, a real test viewing chosen for illustration, at the 99.8th percentile of skill.
Figure 4: Scaling on continuous EEG. Forecast correlation on held-out recordings of the 15 core subjects against pooled training EEG; shaded, EEG-World’s lead. Right, all cores and the stateless forecasters at 2,012 h.
Figure 5: Video trials. Held-out clips of the 15 core subjects against the amount of video-paired training EEG. (a) Forecast correlation. (b) Clip-locked correlation (SLv) between the clip-driven part of each forecast and the mean EEG of the other viewers, in percent of the noise ceiling; shaded, below +2 SD of a shuffled-clip null.
Model (15 subjects, test clips)
r
skill
swap cost ( r )
Context mean
.180
0
–
Linear, EEG only
.225
.1909
–
Linear, EEG + video
.233
.1928
.012
MLP, no state
.242
.1948
–
iTransformer, no state
.248
.1982
–
EEG-World, EEG + clip onset
.255
.2034
–
Table 2: Video trials. The clip-onset model is fine-tuned on the same trials but told only when each clip starts; the no-state models are the direct forecasters of Sec. 4 ; the swap cost is the correlation lost when the clip is replaced by another test clip.
Figure 6: Unseen subjects. 24 subjects never used in development; frozen models with a per-subject linear head. (a) Gain over the best history + video linear model, in percent of its r , with the subjects ahead. (b) A model retrained without these subjects, against each subject’s own calibration data; dashed, the best linear model fitted on all of it. (c) Correlation lost when the clip is swapped; dots, subjects.
Figure 7: Where, when and what. (a) Gain over the best linear model at each electrode and band, in percent of its r , and the horizon gained. (b) Gain, in percent, against the distance of the starting state from the subject’s mean. (c) In-silico tuning, the forecast change when one input feature is raised, against the tuning of recorded EEG across viewers, for every feature and electrode–band cell; right, maps of two features. Panel (c) uses validation data only.
Figure 8: Identifying the clip from forecasts. Each viewing keeps its real context and is forecast with each of the 394 test clips as the action; candidates are ranked by fit to the recorded EEG. (a) An example test clip, shown by one frame and its event label. (b) The viewing with the median rank of the true clip. (c) Mean over all 183 viewings of this frequently repeated clip. (d) All test clips, pooling random subsets of viewings. Post hoc.
Clip features
Modality
SLv
r
V-JEPA 2 [ 3 ]
Video
.188
.261
CLIP + DINOv2 (main visual input)
Image
.139
.260
CLIP [ 6 ]
Image
.133
.261
DFN [ 11 ]
Image
.126
.255
VideoMAE [ 45 ]
Video
.115
.255
MAE [ 19 ]
Image
.110
.255
Table 3: Ranking clip features. The video pathway is fed one feature set at a time, 24 principal components each, three seeds. SLv as in Fig. 5 b, without noise-ceiling normalization.
Appendix figures & tables9 assets
Supplementary material from the paper’s appendix.
Appendix
Figure S1 : Viewers who start a clip in different states stay different. All 10,970 test viewings of the 15 core subjects. (a) Weights of the most persistent component of the 155 features, learned from training viewings only: the direction whose mean over the 6 s before a clip correlates best with its mean over seconds 2–10 of the clip, after removing each clip’s mean response over the other viewers ( λ is that correlation). (b) The first principal component of the pre-clip means (36% of their variance). (c) Each feature on its own: viewers in the top and bottom 10% of the feature’s pre-clip mean, their difference over seconds 2–10 of the clip, measured and predicted from the video alone (the mean response of the other 14 subjects to the same clip). (d) The same difference for three state variables.
Variant (video trials)
r
Δr [95% CI]
full ahead
EEG-World (full)
.260
–
–
no per-subject heads
.240
−.020 [ −.023 , −.017 ]
15/15
3-s context (not 6 s)
.249
−.011 [ −.013 , −.009 ]
15/15
no pretraining
.251
−.009 [ −.011 , −.007 ]
14/15
clip onset only
.253
−.007 [ −.012 , −.002 ]
10/15
no continuous windows
.258
−.0016 [ −.0030 , −.0004 ]
11/15
Appendix
Table S1 : Ablations on the core subjects’ test viewings, one change at a time, three seeds each.
Figure S2 : Visual and audio features. Gain in forecast r on the test clips from each kind of feature: the main effect in a 2×2 design of models retrained with visual features, audio features, both or neither (three seeds each), averaged over the 10 forecast steps. (a) Subject means at each electrode and band, on one scale. (b) Band means over all electrodes with bootstrap 95% intervals over the 15 subjects.
908 h
2,012 h
Model
Params
r
skill
r
skill
Best linear (history ridge)
–
.2716
.1745
.2718
.1746
Linear world model ∗
–
.2572
.1655
–
–
EEG-World (GRU)
1.6M
.2809
.1787
.2844
.1804
+ JEPA latent loss
1.6M
–
–
.2859
.1813
908 h data, 2,012 h budget
1.6M
.2824
.1795
–
–
Appendix
Table S2 : Continuous EEG, no video. Held-out sessions of the 15 core subjects, seed means; parameters of the core only. ∗ EEG-World’s architecture and training without nonlinearity.
Figure S3 : Trajectory matching [ 9 ] within each subject’s test viewings: top-10 accuracy per subject with mean and 95% CI, in multiples of chance. The context mean ignores the video.
Comparison
Effect [95% CI]
rel.
k/n
p
Test
Continuous EEG ( Sec. 6.1 , Fig. 4 )
vs. best linear, 14 h
−20.7%
0/15
vs. best linear, 56 h
−7.7%
0/15
vs. best linear, 227 h
−2.8%
2/15
vs. best linear, 685 h
+3.5%
15/15
6×10−5
H10
in skill
+0.0042
Appendix
Table S3 : Statistics of the main-text comparisons, Secs. 6.1 and 6.2 . Rows starting with “vs.” compare EEG-World with the named model. Effect: difference in r with its 95% interval, unless a unit is given or the row reads “in skill”; rel.: in percent of the other model’s r ; k/n : subjects ahead. Best linear: the best per-subject, pooled or hierarchical ridge model on EEG history, with the video features on trials; on continuous EEG it reaches r=0.272 at 908, 1,142 and 2,012 h. SLv: clip-locked correlation. Test: the pre-registered test that decided the row ( Tabs. S5 and S6 ); other rows are secondary or descriptive.
Comparison
Effect [95% CI]
rel.
k/n
p
Test
Unseen subjects ( Sec. 6.3 , Fig. 6 )
Frozen video model ( Fig. 6 a) vs. best linear
+0.020 [0.013, 0.027]
+8.1%
23/24
clip <10−5
H13
in skill
+0.0083
Retrained model ( Fig. 6 b), all own data
+9.7%
24/24
H26
No-video world model vs. best linear
+6.8%
21/24
Video vs. no-video world model
+0.003
0.20
Appendix
Table S4 : Statistics of the main-text comparisons, Secs. 6.3 to 6.5 , as in Tab. S3 . Clip: test over the 394 test clips (sign-flip for H13, bootstrap for H58). ∗ Against a linear model fitted on all of the subject’s data, a median of 2,046 trials (5.7 h); descriptive.
Test
Hypothesis
Result
k/n
Outcome
Continuous EEG, held-out sessions of the 15 core subjects
H1
Per-subject world model vs. per-subject ridge, ≈46 h each
−0.0021 ( p=0.009 )
2/15
failed
H2
The gap of H1 shrinks from 1 to 48 recordings per subject
−0.052 to −0.002
15/15
met
H3
World model pooled over the 15 subjects (908 h) vs. per-subject ridge
+0.0050
15/15
met
H5
The pooled world model vs. best linear
+0.0043
14/15
met
H6
The pooled world model vs. the linear world model
+0.025
15/15
met
Appendix
Table S5 : Pre-registered tests on continuous EEG and on the lab cap. Differences in skill unless noted, favoring the first-named model; k/n counts subjects with a positive difference; linear models as in Tab. S3 . ‡ Pretrained on the same data plus 142 h from the 128-channel net and 71 h from the EEG Moments Dataset.
Test
Hypothesis
Result
k/n
Outcome
Video trials, test viewings of the 15 core subjects
H4 †
Video model trained from scratch (150 h) vs. per-subject history + video ridge
−0.004
3/15
failed
H8 †
Video model fine-tuned from the continuous core vs. best linear
+0.0007
8/15
failed
H11 †
Second attempt at H8 (wider learning-rate grid; clip-level p<0.025 )
+0.0047 (clip p=0.0019 )
12/15
met
H9 †
The fine-tuned model vs. the model trained from scratch
+0.0128
15/15
met
H21 †
EEG-World vs. best linear, 630 h
+0.0103
15/15
met
Appendix
Table S6 : Pre-registered tests on video trials , of the 15 core subjects and of the 24 unseen subjects, as in Tab. S5 . SLv: clip-locked correlation. † Decided at the clip level (sign-flip over the 394 test clips) together with the subject count. ‡ As in Tab. S5 . § One of three seeds stopped at epoch 0.
Electroencephalography (EEG) studies brain-generated electrical activity to understand cognition and support diagnosis, monitoring, and brain-computer interfaces.
Georgia Institute of Technology · Center for Translational Research in Neuroimaging and Data Science · University of Texas Health Science Center at Houston
Concordia Institute for Information Systems Engineering (CIISE), Concordia University, Canada. · Department of Electrical and Computer Engineering, University of Toronto, Canada