Spectral imaging captures information that ordinary RGB sensors cannot, but dedicated spectral cameras can be expensive and bulky. Recovering dense spectra from RGB images offers an accessible alternative, but distinct spectra can produce the same camera response, generating an ambiguity that even more advanced recovery algorithms cannot always resolve. Therefore, increasing the spectral information captured at acquisition is essential. We propose DualSpec, a stereo acquisition framework that jointly optimizes two external optical filters and a reconstruction network. Each filter is placed in front of a standard RGB camera, and the two are designed to produce six responses that provide complementary information for the network. Experiments across reconstruction architectures and spectral ranges show that DualSpec reduces mean spectral angle error by 36-72% relative to a single RGB camera and by 11-29% relative to stereo pairs selected from commercial filters. Cross-dataset evaluations, including a new benchmark of spectral images captured from displaced viewpoints, show that the method generalizes and remains robust to viewpoint misalignment, while analyses of thin-film approximations support optical feasibility.
Figures & tables
Figure 1: Cross-dataset reconstruction with MST++ [ 8 ] on a scene from the CAVE dataset [ 52 ] . The artificial (A) and real (B) peppers look similar in RGB but have distinct spectra. The complementary measurements acquired by DualSpec yield reconstructions that better distinguish the spectral signatures of the two samples than those obtained with a single RGB camera. Solid and dashed curves represent ground-truth and reconstructed spectra, respectively. The reported spectral angle (SAM) measures the separation between the two reconstructed spectra.
Figure 2: Attachments learned with MST++ [ 8 ] (top left), effective sensitivities (bottom left), and the resulting network inputs for an Arad-1K scene. Solid and dashed curves correspond to the first and second cameras.
Backbone
Acquisition / selection
SAM ( ∘ ) ↓
RMSE ×1000↓
PSNR ↑
Mean
Median
P95
Mean
Median
P95
Mean
Median
P05
MLP
Single RGB
7.89
6.04
21.05
25.4
16.7
75.0
35.26
35.54
22.50
Single + learned filter
6.21
4.81
16.61
16.7
11.0
51.1
38.62
39.18
25.82
Reutsky Lee
5.57
4.47
13.84
14.9
11.0
38.6
39.05
39.19
28.27
Shrestha Lee
5.81
4.52
16.07
17.3
11.6
48.2
38.16
38.73
26.35
Reutsky Omega
5.33
4.39
12.69
13.8
10.7
36.7
39.60
39.39
28.70
Table 1: Spectral reconstruction on Arad-1K. Superscripts identify the filter bank used by each selection method. Bold values indicate the best result within each backbone and statistic, while blue shading identifies DualSpec.
Backbone
Acquisition / selection
SAM ( ∘ ) ↓
RMSE ×1000↓
PSNR ↑
Mean
Median
P95
Mean
Median
P95
Mean
Median
P05
MLP
Single RGB
8.53
6.61
20.70
26.0
18.3
93.8
30.94
32.85
20.57
Single + learned filter
3.31
3.13
6.87
10.8
9.6
22.5
36.99
37.08
32.96
DualSpec (Ours)
2.35
2.15
4.81
6.9
6.3
15.3
40.80
40.80
36.32
EDSR
Single RGB
2.75
2.82
4.66
9.2
8.8
16.9
38.82
38.98
33.03
Single + learned filter
2.33
2.22
3.60
7.9
7.5
16.0
39.69
39.81
34.86
Table 2: Spectral reconstruction on BGU-ICVL over 400–1000 nm. Commercial-filter baselines are omitted because their measured responses do not extend beyond 700 nm. Bold values indicate the best result within each backbone and statistic, while blue shading identifies DualSpec.
Figure 3: Qualitative reconstruction on two Arad-1K test scenes. For each backbone, we compare single RGB, two stereo pairs selected from the Lee filter bank, and DualSpec. The figure shows spatial RMSE maps and reconstructed spectra at the marked pixels.
Figure 4: Qualitative results on BGU-ICVL (top) and our displaced-view benchmark (bottom). The top example compares single-camera and DualSpec reconstruction over 400–1000 nm. The bottom example compares single-camera, selected-filter stereo, and DualSpec reconstruction after registering the independently captured views.
Backbone
Acquisition / selection
SAM ( ∘ ) ↓
RMSE ×1000↓
PSNR ↑
Mean
Median
P95
Mean
Median
P95
Mean
Median
P05
MLP
Single RGB
8.57
8.94
12.28
42.1
42.3
67.8
27.96
27.49
23.38
Single + learned filter
7.88
8.25
10.77
35.7
35.9
59.4
29.54
28.89
24.53
Reutsky Lee
7.26
7.43
10.42
34.3
36.2
52.8
29.77
28.85
25.55
Shrestha Lee
7.02
7.03
10.25
34.6
36.8
52.5
29.66
28.69
25.61
Reutsky Omega
6.50
6.71
9.53
31.9
32.0
48.2
30.49
29.90
26.37
Table 3: Cross-dataset spectral reconstruction on registered displaced-view pairs. The right view is the reference, and all methods are evaluated over the same valid region. Superscripts identify the filter bank used by each selection method. Bold values indicate the best result within each backbone and statistic, while blue shading identifies DualSpec.
Attachment basis
Δg
σg
B
Mean SAM ( ∘ ) ↓
MLP
EDSR
MST++
Best selected pair
–
–
–
5.33
2.39
2.28
Lee OD
–
–
8
5.40
2.54
2.14
Omega OD
–
–
12
4.85
2.27
2.11
Gaussian
40
40
8
4.87
2.13
2.06
Gaussian
20
40
16
4.80
2.08
2.09
Table 4: Attachment parameterization on Arad-1K (mean SAM in degrees). OD: optical-density bases factorized from the Lee or Omega catalog; Gaussian: Eq. ( 3 ) with spacing Δg and width σg in nm; B : number of bases.
Backbone
Attachments
Att. RMSE ↓
Thick. ( \SIUnitSymbolMicrom )
SAM ( ∘ ) ↓
RMSE × 1000 ↓
PSNR ↑
Reutsky Omega
–
–
5.33
13.76
39.60
Learned (DualSpec)
–
–
4.73
10.93
41.59
Thin film, J=30
0.032
5.09
5.14
12.69
40.48
MLP
+ fine-tuning
4.87
11.37
41.26
Reutsky Lee
–
–
2.39
6.37
46.36
Learned (DualSpec)
–
–
2.02
5.30
47.98
Table 5: Thin-film approximation on Arad-1K with J=30 layers. Thin film : the learned attachments are replaced by the transmittances of the fitted stacks, with the unchanged network; + fine-tuning : the network is fine-tuned on the thin-film attachments. Att. RMSE : thin-film against learned transmittance, mean of the two attachments; Thick. : thickness of the thicker of the two stacks.
Figure 5: Thirty-layer thin-film approximations of the two attachments learned with MST++. The curves compare the learned targets with their thin-film fitted transmittances. The bars below show the alternating Ti3O5 and SiO2 layers to scale. The same thin-film approximation plots for the other backbones can be found in the supplementary material.
Figure S1 : Filter pairs selected from the Lee and Omega Optical banks by the adapted Reutsky and Shrestha criteria: transmittances (top) and resulting effective sensitivities of the two cameras (bottom) on Arad-1K. Solid and dashed curves correspond to the first and second cameras, respectively.
Figure S2 : Representative transmittance curves from the retained Lee (left) and Omega Optical (right) filter banks. Lee gels predominantly provide broad absorptive responses, whereas the Omega catalog also contains sharper interference-filter responses such as bandpass, notch, and multiband designs.
Figure S3 : Learned attachment transmittances (top) and resulting effective RGB sensitivities (bottom) for the MLP, EDSR, and MST++ reconstructors. Transmittances are absolute (the fraction of light passed), and sensitivities include them, so lower curves mean less collected light. Solid and dashed curves correspond to the first and second cameras, respectively.
Figure S4 : Learned attachment transmittances (top) and resulting effective RGB sensitivities (bottom) for VNIR reconstruction on BGU-ICVL. Columns correspond to the MLP, EDSR, and MST++ reconstructors. Solid and dashed sensitivity curves denote the first and second cameras, respectively.
Figure S5 : Complete J=30 thin-film realizations on Arad-1K for MLP (left), EDSR (center), and MST++ (right). Each panel compares the learned and fitted transmittances for both attachments and shows the alternating Ti3O5 / SiO2 stacks to scale.
Figure S6 : Complete J=30 thin-film realizations over 400–1000 nm on BGU-ICVL for MLP (left), EDSR (center), and MST++ (right). The wider spectral interval produces larger fitting errors than the visible-only Arad-1K designs.
SSR
Attachments
Att. RMSE ↓
Thick. ( \SIUnitSymbolMicrom )
SAM ( ∘ ) ↓
RMSE × 1000 ↓
PSNR ↑
MLP
Learned (DualSpec)
–
–
2.35
6.93
40.80
Thin film, J=30
0.043
4.93
2.46
7.37
40.28
+ fine-tuning
2.36
6.92
40.82
EDSR
Learned (DualSpec)
–
–
1.75
5.16
43.36
Thin film, J=30
0.061
4.59
1.88
5.84
42.13
+ fine-tuning
1.73
5.09
43.51
Table S1 : Thin-film approximation of the learned attachments on BGU-ICVL over 400–1000 nm with J=30 layers. Thin film : the learned attachments are replaced by the transmittances of the fitted thin-film stacks, with the network left unchanged. + fine-tuning : the network is additionally fine-tuned on the thin-film attachments. Att. RMSE : RMSE between the thin-film and learned transmittances, averaged over the two attachments. Thick. : thickness of the thicker of the two stacks.
Figure S7 : The ten independently acquired spectral-image pairs in the displaced-view benchmark. Each L/R pair was captured with a 2 cm horizontal camera displacement. Five scenes are staged indoor arrangements, the remaining five are outdoor scenes.
SSR
Acquisition / selection
SAM ( ∘ ) ↓
RMSE ×1000↓
PSNR ↑
Mean
Median
P95
Mean
Median
P95
Mean
Median
P05
MLP
Single RGB
8.60
8.95
12.34
42.6
42.6
68.0
27.89
27.44
23.36
Single + learned filter
7.93
8.26
10.82
36.1
36.9
59.6
29.46
28.67
24.51
Reutsky Lee
7.57
7.89
10.51
38.3
39.3
59.6
28.99
28.11
24.52
Shrestha Lee
7.26
7.21
10.45
37.9
39.0
55.8
29.03
28.18
25.06
Reutsky Omega
6.68
6.91
9.81
33.4
34.3
51.6
30.17
29.28
25.74
Table S2 : Cross-dataset spectral reconstruction on registered displaced-view pairs. The left view is the reference, and all methods are evaluated over the same valid region. Superscripts identify the filter bank used by each selection method. Bold values indicate the best result within each backbone and statistic, while blue shading identifies DualSpec.
SSR
Acquisition / selection
SAM ( ∘ ) ↓
RMSE ×1000↓
PSNR ↑
Mean
Median
P95
Mean
Median
P95
Mean
Median
P05
MLP
Single RGB
8.60
8.95
12.34
42.6
42.6
68.0
27.89
27.44
23.36
Single + learned filter
7.93
8.26
10.82
36.1
36.9
59.6
29.46
28.67
24.51
Reutsky Lee
7.30
7.65
10.28
33.2
33.7
53.7
30.10
29.47
25.40
Shrestha Lee
6.91
7.06
9.90
33.1
35.0
52.5
30.09
29.13
25.60
Reutsky Omega
6.32
6.54
9.10
28.7
27.8
47.9
31.38
31.18
26.41
Table S3 : Displaced-view benchmark without misalignment, left view as the reference: both cameras acquire the reference view, so the stereo input needs no registration. Bold values indicate the best result within each backbone and statistic, while blue shading identifies DualSpec.
SSR
Acquisition / selection
SAM ( ∘ ) ↓
RMSE ×1000↓
PSNR ↑
Mean
Median
P95
Mean
Median
P95
Mean
Median
P05
MLP
Single RGB
8.57
8.94
12.28
42.1
42.3
67.8
27.96
27.49
23.38
Single + learned filter
7.88
8.25
10.77
35.7
35.9
59.4
29.54
28.89
24.53
Reutsky Lee
7.26
7.65
10.23
32.7
33.0
53.6
30.18
29.63
25.42
Shrestha Lee
6.86
7.04
9.84
32.6
34.3
52.4
30.16
29.27
25.62
Reutsky Omega
6.29
6.52
9.05
28.3
27.0
47.8
31.46
31.38
26.42
Table S4 : Displaced-view benchmark without misalignment, right view as the reference: both cameras acquire the reference view, so the stereo input needs no registration. Bold values indicate the best result within each backbone and statistic, while blue shading identifies DualSpec.
SSR
Acquisition / selection
SAM ( ∘ ) ↓
RMSE ×1000↓
PSNR ↑
Mean
Median
P95
Mean
Median
P95
Mean
Median
P05
MLP
Single RGB
14.23
12.97
21.05
40.6
38.9
90.8
28.01
27.81
20.48
Single + learned filter
14.10
12.65
23.52
35.4
33.1
81.8
29.37
29.21
21.38
Reutsky Lee
12.57
11.60
18.13
31.0
30.1
55.2
30.09
29.89
24.77
Shrestha Lee
12.60
11.89
18.41
36.2
35.2
79.9
29.17
28.71
21.72
Reutsky Omega
11.77
10.87
17.11
30.6
29.3
55.2
30.30
30.07
24.79
Table S5 : Cross-dataset spectral reconstruction on CAVE. Arad-1K models are evaluated without fine-tuning, on the object pixels given by the segmentation masks (the dark background is excluded, see the text). Superscripts identify the filter bank used by each selection method. Bold values indicate the best result within each backbone and statistic, while blue shading identifies DualSpec.
Figure S8 : Cross-dataset qualitative results on three CAVE scenes, with the Arad-1K models and no fine-tuning. The RMSE maps are restricted to the object pixels of the segmentation masks (background in gray), and the marked pixel is chosen within the objects. Spectra at the marked pixels compare single RGB, two Lee-bank stereo baselines, and DualSpec for all three backbones.
Figure S9 : Additional qualitative results on three extra Arad-1K test scenes. Spatial RMSE maps and spectra at the marked pixels compare single RGB, two Lee-bank stereo baselines, and DualSpec over 400–700 nm for all three backbones.
Figure S10 : Additional qualitative results on three extra BGU-ICVL test scenes. Spatial RMSE maps and spectra at the marked pixels compare single RGB with DualSpec over 400–1000 nm for all three backbones.
Figure S11 : Additional qualitative results on three extra scenes of our displaced-view benchmark. Over the registered common region, spatial RMSE maps and spectra at the marked pixels compare single RGB, two Lee-bank stereo baselines, and DualSpec for all three backbones.