IMPACT-Seg: Consistent Anatomical Segmentation and Representation Learning Across CT, CBCT, and MRI
Authors: Cédric Hémon, Valentin Boussot, Matthew McCormick, Lukas Zimmermann, Christopher Kurz, Guillaume Landry
Organizations: Department of Radiation Oncology, LMU University Hospital, LMU Medizin, LMU Munich, Germany · Bavarian Cancer Research Center (BZKF), Munich, Germany · Fideus Labs, Durham, NC 27713, United States · Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria · German Cancer Consortium (DKTK), partner site Munich, a partnership between DKFZ and LMU University Hospital Munich, Germany
Computed tomography (CT), cone-beam CT (CBCT), and magnetic resonance imaging (MRI) provide complementary representations of the same underlying anatomy, yet substantial differences in image appearance challenge consistent segmentation and deformable registration in adaptive radiotherapy. We investigate whether dense anatomical segmentation supervision can promote cross-modality correspondence without explicit feature alignment. We introduce IMPACT-Seg, which segments 126 structures across CT, CBCT, and MRI using shared network parameters. A collection of 8,290 volumes was assembled from public cohorts through label harmonization, model-assisted pseudo-label completion, iterative refinement, and 2,864 physics-based CBCT simulations with voxel-aligned CT labels. Unpaired images were used to jointly train 2.5D and 3D residual-encoder networks. On 139 real CBCTs, IMPACT-Seg 3D achieved a mean Dice of 0.842 versus 0.671 for the strongest comparator. On 497 voxel-aligned CT-simulated-CBCT pairs, the CT-to-CBCT Dice decrease was 0.022 versus 0.153-0.178 for competing methods. On independent pancreatic radiotherapy CBCTs, gastrointestinal Dice was 0.735 versus 0.634 for TotalSegmentator. Prediction agreement reached 0.881 on registered CT-CBCT and 0.790 on CT-MRI pairs. Adding MRI training data reduced CT-MRI encoder feature retrieval error from 36.8 to 3.2 mm. Registration pipelines incorporating IMPACT-Seg features ranked first on two multimodal Learn2Reg benchmarks. The 3D model segmented a whole-body CT in 15 s. These findings show that dense anatomical segmentation supervision can support consistent anatomical representations across modalities, with applications to both segmentation and registration. Code, datasets, and pretrained models are available at https://github.com/HEMONCedric/IMPACTSeg.
Figures & tables
Figure 1: Overview of IMPACT-Seg. Public CT, MRI and CBCT cohorts are harmonized into one label map of 126 structures (coronal and sagittal views of a held-out CT), CBCTs are simulated from source CT volumes with voxel-aligned labels, and two networks, a 2.5D and a 3D residual-encoder U-Net, are trained jointly on the three modalities with the same loss and optimization settings. Bottom: evaluation protocol.
Figure 2: Simulated CBCTs. For two patients, the source CT and three simulated CBCT realizations on the same axial slice, with the scanner geometry and the artefacts simulated for each realization. Implants appear on the displayed slices: sternal wires (thorax, Varian OBI) and a hip prosthesis (pelvis). The CBCTs are reconstructed back onto the CT grid and inherit its labels voxel by voxel.
Figure 3: Cross-modality consistency. (a) CT-to-CBCT domain shift on voxel-aligned simulated pairs. (b) Reference-free agreement between the predictions of the planning CT and of the deformably registered real CBCT or MRI of the same patient, on the patient-label pairs of the benchmark tables.
Figure 4: Per-case mean Dice of IMPACT-Seg (2.5D and 3D networks; ens.: five-fold ensemble on the external cohorts) and the compared frameworks on every benchmark (boxes: interquartile range; whiskers: 1.5 IQR; diamonds: means; dots: cases). A method trained on the images of a benchmark is not shown on it (Section 3.7 ).
Figure 5: Internal out-of-fold Dice of the 126 structures grouped by anatomical region (number of structures in parentheses), per modality and network: each dot is the median Dice of one structure over the test cases whose reference contains it (a missed structure counts as 0), and boxes summarize the structures of a group. For MRI, 50 of the 140 TotalSegmentator-MR test cases are drawn so that this cohort does not dominate. The Dice of every structure is given in Figures S8 - S9 .
Metric
CT only
+ real CBCT
+ sim. CBCT
+ MRI (full)
Training volumes
624
763
1248
1872
CBCT share of training slices
0%
10%
45%
30%
CBCT
SynthRAD CBCT (real), Dice
0.775
0.798 ∗
0.810 ∗
0.808 ∗
Internal real CBCT, Dice
0.649
0.723 ∗
0.733
0.724
Simulated CBCT (TS_RTK), Dice
0.750
0.756 ∗
0.830 ∗
0.821 ∗
Table 4: Training-data ablation (2.5D network, fold 1, AdamW; checkpoint at 200 000 steps): training sets of increasing composition, from CT only to the full multimodal set (number of training volumes and share of CBCT among the training slices, which are sampled uniformly), evaluated on the fold-1 cases of each benchmark (same patient–label pairs as Table 2 ) and of the internal test set (126 structures). Dice drop: CT minus CBCT Dice of the same patient; agreement: Dice between the CT and CBCT predictions. ∗ : different from the previous column (paired Wilcoxon test, Holm-corrected, p<0.05 ).
Figure 6: Feature-level consistency of the 2.5D networks on paired volumes from patients excluded from all compared models. (a) For a query point on the CT (green cross), similarity of its feature to the features of every position of the same slice of the paired image, at three depths (scaled per panel). The cyan circle marks the most similar position within the 96 mm search disc (dashed), and the number its distance to the true position. Top two rows: main fold-1 network; bottom row: network of the ablation trained on CT only, same query point. The query point was selected from the slice’s reference points based on proximity to the networks’ cohort-level retrieval statistics at the fifth encoder stage and last decoder layer. (b, c) Main fold-1 network: mean of the patient-wise median retrieval errors within a 96 mm disc (logarithmic scale; dotted: chance, 68 mm) and discrimination between features from different structures (AUC), as a function of depth (shaded: encoder). (d) Similarity of the last-decoder features across modalities (linear CKA) for the networks of the training-data ablation. Bands and error bars: patient-level bootstrap 95% confidence intervals; simulated CBCT 48, real CBCT 57 and MRI 11 patients.
CT
MRI
Signal
2.5D
3D
2.5D
3D
Structures ( n )
17695
17687
7922
7917
Failure prevalence
16.3%
10.5%
22.7%
18.2%
AUROC
Entropy (inside)
0.83 [0.80, 0.85]
0.73 [0.68, 0.76]
0.83 [0.81, 0.84]
0.60 [0.57, 0.62]
Entropy (boundary band)
0.64 [0.60, 0.67]
0.55 [0.50, 0.61]
0.60 [0.57, 0.63]
0.40 [0.37, 0.43]
Table 6: Detection of structures with Dice < 0.7 from uncertainty on the external TotalSegmentator v3 cohorts: AUROC and AUPRC with patient-level bootstrap 95% confidence intervals (10 000 resamples). Random baseline: AUROC 0.5 and AUPRC equal to the failure prevalence. Structures not predicted at all are excluded (they carry no uncertainty). The volume baseline ranks structures by their predicted volume only (smaller is riskier).
Figure 7: Failure cases, selected on all five folds by the mean of the 2.5D and 3D networks. Top: held-out CT with the lowest rate of correctly identified vertebral levels; vertebrae are coloured by level, so that a level shift appears as a colour change: the 2.5D network shifts the lumbar levels, which the 3D network identifies correctly. Middle: external MRI with the lowest Dice (partial liver miss of the 2.5D network, recovered by the 3D network). Bottom: real thoracic CBCT with the lowest Dice; ribs and vertebrae are delineated but shifted by one level by both networks. Titles give the mean Dice of the case.
Framework
Code
Pretrained weights
CADS
1.0.2; commit 29d90ca04216
cads-model_v1.0.0
MRSegmentator
2.0.0
Base 1.2 (release v1.2.0); five-fold ensemble, checkpoint_final.pth
NV-Segment-CTMR
Commit e04af885a0d3 ; MONAI bundle 0.0.1s
model.pt , model revision 4fb8b4a6b253
TotalSegmentator CT/CBCT
2.18.0
CT weights unchanged since 2.0.0; total and head_glands_cavities tasks
TotalSegmentator MRI
2.4.0 (separate environment)
MRI weights distributed with 2.4.0
Table S1: Software and pretrained weights used in the comparisons. Code versions and weight releases are reported separately. Linked commit and model revisions identify the evaluated implementations.
CT
MRI
Signal
2.5D
3D
2.5D
3D
Structures ( n )
17695
17687
7922
7917
Failure prevalence
8.3%
5.0%
8.3%
5.7%
AUROC
Entropy (inside)
0.86 [0.83, 0.89]
0.80 [0.75, 0.85]
0.86 [0.83, 0.89]
0.66 [0.62, 0.70]
Entropy (boundary band)
0.68 [0.63, 0.73]
0.64 [0.56, 0.71]
0.69 [0.64, 0.73]
0.46 [0.41, 0.50]
Table S14: Detection of structures with Dice < 0.5 from uncertainty on the external TotalSegmentator v3 cohorts: AUROC and AUPRC with patient-level bootstrap 95% confidence intervals (10 000 resamples). Random baseline: AUROC 0.5 and AUPRC equal to the failure prevalence. Structures not predicted at all are excluded (they carry no uncertainty). The volume baseline ranks structures by their predicted volume only (smaller is riskier).
Volume
Net.
Prev.
Entropy
Fold dis.
2.5D/3D dis.
1 − conf.
Volume
< 10 ml
2.5D
46%
0.87
0.89
0.88
0.86
0.66
3D
39%
0.74
0.89
0.81
0.69
0.70
10–100 ml
2.5D
19%
0.80
0.90
0.90
0.81
0.61
3D
11%
0.69
0.92
0.85
0.64
0.59
≥ 100 ml
2.5D
5%
0.93
0.95
0.91
0.92
0.57
3D
3%
0.85
0.95
0.88
0.80
0.63
Table S15: Failure detection (AUROC, Dice < 0.7) per reference volume of the structure, TotalSegmentator v3 CT and MRI pooled. Within a volume range, the size of the structure alone carries little information, whereas the disagreement signals remain discriminative.
Network
Signal
Reviewed
Failures captured
Unflagged failures
Workload saved
2.5D
Fold disagreement (inside)
5%
24% (1143/4751)
3608
95%
2.5D
Fold disagreement (inside)
10%
46% (2165/4751)
2586
90%
2.5D
Fold disagreement (inside)
20%
75% (3572/4751)
1179
80%
2.5D
Fold disagreement (inside)
30%
87% (4116/4751)
635
70%
3D
Fold disagreement (inside)
5%
33% (1107/3394)
2287
95%
3D
Fold disagreement (inside)
10%
58% (1974/3394)
1420
90%
Table S16: Triage of the structures by fold disagreement (Dice < 0.7, TotalSegmentator v3 CT and MRI): share of the failing structures captured when the given fraction of the most uncertain structures is reviewed, failures left unflagged (including the structures not predicted at all, which are never flagged). Random review captures, on average, the reviewed fraction.
Figure S1: Calibration on the external TotalSegmentator v3 CT and MRI cohorts. Left and middle: voxel-level reliability diagrams of the softmax confidence (accuracy of the predicted label against the reference, over the predicted and reference foreground) with the expected calibration error (ECE). Right: failure rate (Dice < 0.7) of the structures per decile of fold disagreement, CT and MRI pooled.
Figure S2: Fold disagreement inside the predicted structure versus Dice of every evaluated structure of the TotalSegmentator v3 CT and MRI cohorts (logarithmic density), with the Spearman correlation. Dashed line: failure threshold (Dice 0.7).
Figure S3: ROC (top) and precision-recall (bottom) curves for the detection of structures with Dice < 0.7 by the fold disagreement (solid) and by the predicted volume (dotted), with the AUROC in parentheses. Dashed horizontal lines: failure prevalence of each network.
Figure S4: Uncertainty maps of the 3D network on two failures flagged by the fold disagreement in the TotalSegmentator v3 cohorts, on the slice with the largest error of the structure. Top (CT, coronal): large mass at the left kidney, which the network partly labels as kidney (predicted 416 ml, reference 96 ml). Bottom (MRI, axial): under-segmented pancreas, of which the network recovers 26 of the 69 ml of the reference and leaves the rest unlabelled. From left to right: image, prediction, error against the reference on all the structures retained for the case (shown for evaluation only), normalized softmax entropy, fold disagreement (one minus the share of the majority label among the five fold models) and voxels where the 2.5D and 3D networks predict different labels. Cyan: predicted contour of the failing structure. In both cases, the entropy of the single model stays low on the failing structure whereas the fold models disagree.
Figure S5: Representative cases: for each benchmark, the case whose IMPACT-Seg Dice (mean of the 2.5D and 3D networks) is closest to the benchmark median, on the slice containing the most reference structures. Only the structures shared by the compared methods and evaluated in the benchmark are shown; titles give the mean Dice of the case over these structures.
Figure S6: Dense anatomical output of IMPACT-Seg (3D network). Left: surface rendering of the structures predicted on a held-out whole-body CT. Right: predictions on the planning CT and on the registered real CBCT (top) or MRI (bottom) of the same patient; lungs and large muscles are rendered translucent.
Figure S7: Cross-modality agreement in 3D for one SynthRAD patient per cohort (a thoracic CBCT on which every method predicts most structures, and a pelvic MRI). Each method segments the planning CT and the registered CBCT (top) or MRI (bottom); the CBCT/MRI surface of every structure is coloured by its distance to the surface of the same structure predicted on the CT. Structures predicted on the CT but missed on the CBCT/MRI are shown in grey. Titles give the CT–CBCT/MRI agreement Dice of the case.
Figure S8: Dice of each soft-tissue structure (head and neck, thorax, heart and vessels, abdominal organs, bowel and pelvic organs) on the internal out-of-fold test cases, per modality, for the 2.5D and 3D networks. Boxes give the quartiles over the cases whose reference contains the structure (a missed structure counts as 0), whiskers extend to 1.5 times the interquartile range; outliers are not drawn. MRI cases as in Figure 5 .
Figure S9: Dice of each skeletal structure and muscle on the internal out-of-fold test cases, displayed as in Figure S8 .
Figure S10: Internal out-of-fold Dice of the 2.5D and 3D networks per source cohort and modality (126 structures, per-case mean over the labels present in the reference).
Figure S11: Mean CBCT Dice difference between simulated CBCTs with and without each artefact, per method (Mann–Whitney test, Holm correction per method).
Figure S12: Mean Dice by reference structure volume ( < 10 ml, 10–100 ml, ≥ 100 ml) on each benchmark.
Figure S13: Anatomical coverage. For each of the 126 structures of IMPACT-Seg, whether each framework outputs it as a structure of its own on CT and on MRI (red). IMPACT-Seg provides all of them with the same model on CT, CBCT and MRI. Its label space was derived from the CADS tasks, so CADS covers the same structures on CT; TotalSegmentator and NV-Segment-CTMR cover about 100 on CT and 43 on MRI, MRSegmentator 36 on MRI. Whole organs (e.g. heart, lungs) do not count as their substructures.
Figure S14: Illustrative cases selected for reference agreement: for each benchmark, a case whose reference agrees most closely with the compared methods (competitors on the planning or source CT for the CBCT benchmarks), checked visually. Display as in Figure S5 . These cases are selected for readability and their Dice values are not representative of the benchmark means.
NV-Segment-CTMR
TotalSegmentator
IMPACT-Seg 2.5D
IMPACT-Seg 3D
Label
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Aorta
0.857 ± 0.064
6.389 ± 8.085
0.851 ± 0.061
7.014 ± 8.175
0.856 ± 0.060
6.594 ± 8.114
0.851 ± 0.062
6.877 ± 8.317
Colon
0.880 ± 0.038
7.376 ± 5.039
0.906 ± 0.031
4.930 ± 2.919
0.877 ± 0.040
7.794 ± 5.302
0.899 ± 0.028
4.695 ± 2.239
Duodenum
0.540 ± 0.084
6.567 ± 3.645
0.828 ± 0.081
4.884 ± 3.051
0.789 ± 0.110
6.980 ± 5.383
0.817 ± 0.097
5.203 ± 3.914
Esophagus
0.812 ± 0.075
4.058 ± 4.327
0.834 ± 0.089
4.175 ± 5.321
0.827 ± 0.078
3.902 ± 4.396
0.822 ± 0.081
4.043 ± 4.684
Gallbladder
0.700 ± 0.159
9.025 ± 8.500
0.727 ± 0.132
7.018 ± 4.499
0.701 ± 0.144
7.695 ± 6.328
0.706 ± 0.145
7.229 ± 4.304
Table S18: Label-wise comparison on the held-out VISCERAL CT benchmark (unseen patients from the VisceralGC and VisceralGCsilver cohorts) (mean ± standard deviation over evaluated patient–label pairs; HD95 in mm). Best values for each label in bold.
CADS
NV-Segment-CTMR
TotalSegmentator
IMPACT-Seg 2.5D (5-fold ens.)
IMPACT-Seg 3D (5-fold ens.)
Label
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Aorta
0.936 ± 0.084
3.831 ± 7.648
0.902 ± 0.107
18.837 ± 104.820
0.962 ± 0.084
2.436 ± 5.701
0.926 ± 0.124
3.499 ± 8.216
0.931 ± 0.105
3.880 ± 9.501
Colon
0.883 ± 0.103
8.338 ± 9.845
0.827 ± 0.111
46.809 ± 110.132
0.936 ± 0.050
3.394 ± 3.444
0.836 ± 0.110
15.126 ± 14.943
0.874 ± 0.098
9.500 ± 10.774
Duodenum
0.841 ± 0.121
6.870 ± 10.679
0.767 ± 0.146
14.693 ± 51.344
0.905 ± 0.074
3.228 ± 5.706
0.757 ± 0.153
10.522 ± 11.215
0.802 ± 0.150
8.027 ± 10.910
Esophagus
0.873 ± 0.154
5.037 ± 17.976
0.822 ± 0.151
12.094 ± 68.747
0.934 ± 0.070
3.257 ± 15.519
0.838 ± 0.153
5.388 ± 16.428
0.843 ± 0.128
4.738 ± 15.711
Gallbladder
0.803 ± 0.211
6.841 ± 8.706
0.785 ± 0.213
28.822 ± 94.853
0.917 ± 0.074
2.543 ± 1.891
0.702 ± 0.293
11.781 ± 15.698
0.740 ± 0.283
8.362 ± 11.584
Table S19: Label-wise comparison on the external TotalSegmentator v3 CT cases (absent from v2) (mean ± standard deviation over evaluated patient–label pairs; HD95 in mm). Best values for each label in bold. IMPACT-Seg: five-fold ensembles, as these external cases were seen by no fold.
CADS
NV-Segment-CTMR
TotalSegmentator
IMPACT-Seg 2.5D
IMPACT-Seg 3D
Label
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Aorta
0.764 ± 0.248
13.742 ± 19.299
0.781 ± 0.114
15.189 ± 19.277
0.457 ± 0.419
15.760 ± 22.593
0.851 ± 0.081
6.741 ± 9.256
0.861 ± 0.086
6.551 ± 10.990
Colon
0.533 ± 0.259
40.568 ± 35.919
0.629 ± 0.150
31.771 ± 23.608
0.504 ± 0.300
46.343 ± 45.732
0.662 ± 0.147
25.668 ± 19.851
0.704 ± 0.126
20.122 ± 14.567
Duodenum
0.590 ± 0.199
21.172 ± 22.667
0.440 ± 0.220
32.011 ± 23.631
0.549 ± 0.209
18.446 ± 20.342
0.606 ± 0.134
12.883 ± 9.014
0.648 ± 0.130
11.883 ± 11.738
Esophagus
0.646 ± 0.195
13.823 ± 23.911
0.648 ± 0.126
7.926 ± 7.393
0.670 ± 0.176
9.257 ± 12.337
0.724 ± 0.131
5.933 ± 5.953
0.770 ± 0.079
4.494 ± 2.431
Gallbladder
0.524 ± 0.263
10.432 ± 5.895
0.356 ± 0.401
17.480 ± 12.584
0.483 ± 0.373
12.954 ± 9.544
0.683 ± 0.157
6.468 ± 2.293
0.562 ± 0.326
8.191 ± 5.279
Table S20: Label-wise comparison on the curated SynthRADSegCBCT subset (mean ± standard deviation over evaluated patient–label pairs; HD95 in mm). Best values for each label in bold.
CADS
NV-Segment-CTMR
TotalSegmentator
IMPACT-Seg 2.5D
IMPACT-Seg 3D
Label
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Aorta
0.909 ± 0.137
3.415 ± 4.996
0.883 ± 0.104
5.502 ± 8.613
0.805 ± 0.228
15.576 ± 33.149
0.925 ± 0.079
3.211 ± 4.691
0.924 ± 0.075
2.890 ± 3.313
Colon
0.790 ± 0.189
15.339 ± 25.884
0.754 ± 0.184
15.788 ± 19.835
0.849 ± 0.150
9.251 ± 15.886
0.813 ± 0.122
14.703 ± 14.030
0.853 ± 0.099
10.655 ± 13.122
Duodenum
0.780 ± 0.174
7.359 ± 9.866
0.723 ± 0.201
9.273 ± 9.516
0.847 ± 0.117
4.220 ± 5.201
0.750 ± 0.174
9.774 ± 10.939
0.777 ± 0.177
8.498 ± 10.963
Esophagus
0.740 ± 0.218
6.957 ± 12.593
0.755 ± 0.133
5.074 ± 3.739
0.848 ± 0.083
3.203 ± 3.365
0.838 ± 0.111
3.231 ± 2.507
0.835 ± 0.111
2.909 ± 1.717
Gallbladder
0.696 ± 0.245
9.587 ± 10.033
0.663 ± 0.254
11.460 ± 11.368
0.769 ± 0.205
7.926 ± 9.135
0.751 ± 0.199
10.042 ± 12.082
0.756 ± 0.234
7.463 ± 10.857
Table S21: Label-wise comparison on the TS_RTK simulated CBCT benchmark (mean ± standard deviation over evaluated patient–label pairs; HD95 in mm). Best values for each label in bold.
MRSegmentator
NV-Segment-CTMR
TotalSegmentator
IMPACT-Seg 2.5D
IMPACT-Seg 3D
Label
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Aorta
0.846 ± 0.120
3.957 ± 3.767
0.751 ± 0.174
12.489 ± 19.131
0.828 ± 0.126
11.945 ± 21.050
0.828 ± 0.124
4.404 ± 2.911
0.834 ± 0.147
6.748 ± 14.006
Bladder
0.901 ± 0.087
6.462 ± 9.216
0.873 ± 0.091
6.627 ± 8.117
0.960 ± 0.067
2.608 ± 4.100
0.882 ± 0.075
13.397 ± 32.674
0.881 ± 0.102
5.634 ± 4.859
Colon
0.802 ± 0.111
12.701 ± 9.247
0.746 ± 0.097
17.391 ± 12.880
0.854 ± 0.138
10.748 ± 18.025
0.740 ± 0.096
17.602 ± 9.982
0.784 ± 0.088
15.098 ± 10.310
Duodenum
0.681 ± 0.200
9.681 ± 12.567
0.477 ± 0.257
22.286 ± 20.051
0.737 ± 0.154
9.258 ± 11.439
0.559 ± 0.253
20.729 ± 43.774
0.584 ± 0.290
9.602 ± 7.008
Esophagus
0.756 ± 0.090
6.141 ± 5.971
0.646 ± 0.131
7.360 ± 4.998
0.741 ± 0.138
7.722 ± 9.023
0.767 ± 0.063
5.464 ± 7.165
0.766 ± 0.062
4.839 ± 4.875
Table S22: Label-wise comparison on the curated SynthRAD MRI subset (mean ± standard deviation over evaluated patient–label pairs; HD95 in mm). Best values for each label in bold.
MRSegmentator
NV-Segment-CTMR
TotalSegmentator
IMPACT-Seg 2.5D
IMPACT-Seg 3D
Label
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Aorta
0.892 ± 0.065
12.610 ± 15.955
0.904 ± 0.044
2.490 ± 1.429
0.834 ± 0.055
6.000 ± 7.257
0.895 ± 0.045
3.615 ± 3.556
0.891 ± 0.050
4.296 ± 5.658
Colon
0.840 ± 0.079
7.097 ± 5.508
0.796 ± 0.090
8.726 ± 7.486
0.848 ± 0.071
4.997 ± 4.088
0.821 ± 0.064
9.087 ± 7.527
0.827 ± 0.075
7.412 ± 5.677
Duodenum
0.596 ± 0.158
14.624 ± 8.721
0.752 ± 0.119
8.392 ± 7.210
0.551 ± 0.185
17.415 ± 11.536
0.629 ± 0.139
13.589 ± 9.853
0.648 ± 0.118
10.928 ± 6.128
Esophagus
0.723 ± 0.095
6.368 ± 5.309
0.759 ± 0.118
5.241 ± 7.040
0.720 ± 0.095
6.772 ± 4.963
0.691 ± 0.100
5.410 ± 2.508
0.700 ± 0.079
4.572 ± 1.856
Gallbladder
0.678 ± 0.299
8.834 ± 9.079
0.871 ± 0.078
3.740 ± 3.714
0.667 ± 0.279
8.659 ± 6.710
0.696 ± 0.260
8.999 ± 8.150
0.771 ± 0.183
6.904 ± 6.770
Table S23: Label-wise comparison on the AMOS22 MRI test cases (mean ± standard deviation over evaluated patient–label pairs; HD95 in mm). Best values for each label in bold.
MRSegmentator
NV-Segment-CTMR
IMPACT-Seg 2.5D
IMPACT-Seg 3D
Label
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Aorta
0.712 ± 0.189
21.422 ± 33.709
0.771 ± 0.203
13.694 ± 33.312
0.769 ± 0.171
17.701 ± 38.085
0.757 ± 0.184
14.031 ± 30.019
Bladder
0.845 ± 0.166
7.773 ± 9.523
0.865 ± 0.147
5.540 ± 5.236
0.761 ± 0.210
13.999 ± 16.215
0.784 ± 0.208
13.533 ± 18.002
Colon
0.841 ± 0.107
13.777 ± 25.535
0.803 ± 0.139
12.179 ± 21.002
0.735 ± 0.132
28.000 ± 35.725
0.805 ± 0.098
15.075 ± 24.424
Duodenum
0.765 ± 0.189
11.398 ± 16.636
0.785 ± 0.153
7.000 ± 9.944
0.665 ± 0.195
16.123 ± 17.820
0.675 ± 0.240
15.303 ± 19.775
Esophagus
0.711 ± 0.183
11.056 ± 22.149
0.713 ± 0.162
8.287 ± 11.991
0.616 ± 0.159
14.659 ± 22.322
0.647 ± 0.159
10.778 ± 12.217
Table S24: Label-wise comparison on the curated TotalSegmentator MRI test cases (mean ± standard deviation over evaluated patient–label pairs; HD95 in mm). Best values for each label in bold.
MRSegmentator
NV-Segment-CTMR
TotalSegmentator
IMPACT-Seg 2.5D (5-fold ens.)
IMPACT-Seg 3D (5-fold ens.)
Label
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Dice
HD95
Aorta
0.824 ± 0.103
11.887 ± 15.796
0.809 ± 0.170
10.216 ± 15.833
0.836 ± 0.152
7.758 ± 13.414
0.825 ± 0.135
8.038 ± 12.661
0.825 ± 0.159
6.975 ± 13.227
Bladder
0.878 ± 0.159
5.877 ± 8.446
0.831 ± 0.195
15.600 ± 70.189
0.892 ± 0.131
5.242 ± 6.366
0.846 ± 0.150
9.612 ± 23.478
0.868 ± 0.162
6.254 ± 9.743
Colon
0.820 ± 0.117
12.027 ± 16.650
0.762 ± 0.131
24.938 ± 38.168
0.844 ± 0.126
10.721 ± 17.065
0.767 ± 0.152
18.866 ± 23.528
0.811 ± 0.133
12.575 ± 18.947
Duodenum
0.738 ± 0.177
11.282 ± 13.755
0.673 ± 0.202
19.305 ± 53.588
0.768 ± 0.176
9.302 ± 11.685
0.684 ± 0.206
12.155 ± 11.221
0.712 ± 0.210
11.995 ± 14.388
Esophagus
0.791 ± 0.108
4.811 ± 5.798
0.723 ± 0.164
9.898 ± 44.316
0.812 ± 0.107
4.586 ± 11.143
0.713 ± 0.153
8.568 ± 14.179
0.736 ± 0.137
7.246 ± 11.305
Table S25: Label-wise comparison on the external TotalSegmentator v3 axial MRI cases (absent from v2) (mean ± standard deviation over evaluated patient–label pairs; HD95 in mm). Best values for each label in bold. IMPACT-Seg: five-fold ensembles, as these external cases were seen by no fold.
Benchmark
IMPACT-Seg 2.5D
IMPACT-Seg 3D
SynthRAD CBCT
0.819 [0.804, 0.832]
0.842 [0.831, 0.852]
Simulated CBCT
0.833 [0.826, 0.840]
0.855 [0.849, 0.860]
VISCERAL CT
0.833 [0.822, 0.844]
0.850 [0.841, 0.859]
TotalSegmentator v3 CT
0.799 [0.783, 0.814]
0.831 [0.815, 0.845]
SynthRAD MRI
0.817 [0.803, 0.831]
0.822 [0.807, 0.837]
AMOS-MR
0.808 [0.789, 0.827]
0.816 [0.797, 0.834]
Table S26: Per-case mean Dice and 95% patient-bootstrap confidence intervals for the two IMPACT-Seg networks. Values correspond to the main benchmarks; the bootstrap uses 10000 resamples.
Cross-modality medical image segmentation labels anatomy and disease across imaging types despite differences in appearance, resolution, and available annotations.
Raw image intensities are a poor surrogate for similarity across images in correspondence problems. Further, while auxiliary segmentation labels can provide semantic identification and improve matching, they can assign only coarse identities to fine-grained anatomy and often cover only a subset of structures, particularly in whole-body settings. We present an approach that instead establishes correspondence using complementary representations of anatomy and demonstrate its utility for longitudinal whole-body PET/CT registration in the Learn2Reg 2026 PSMAReg Challenge. We use our 3D foundation model, anatomix, to derive fine-grained, per-voxel semantic representations that are consistent across volumes and further employ off-the-shelf segmentation models to obtain coarse anatomical identities. Together, these representations drive a GPU-accelerated iterative registration solver (FireANTs) in a hybrid multistage framework: the first stage estimates alignment from dense multi-channel features, after which a second refines the deformation using both anatomix- and segmentation-based losses. Lastly, because registration should not introduce non-biological tumor volume changes across time, we develop lesion-specific, component-wise volume preservation schemes. Without any task-specific training, our system placed first on the PSMAReg Challenge leaderboard. Code and interactive visualizations are available at https://www.neeldey.com/reps-for-reg.
Neel Dey, Adrian V. Dalca
A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital · Department of Radiology, Harvard Medical School · Computer Science and AI Lab, Massachusetts Institute of Technology
Accurate 3D segmentation of cone-beam CT (CBCT) is critical for interventional and radiation therapy applications, yet it remains limited by two compounding challenges: the scarcity of annotated CBCT data and the large domain shift from diagnostic CT. Interventional CBCT exhibits fundamental modality differences from conventional CT, driven by acquisition and physics effects as well as contrast-specific vascular content, thereby limiting effective cross-modality model transfer. We propose a novel unsupervised domain adaptation (UDA) framework based on redundancy-reducing feature alignment, enabling 3D CBCT segmentation with no target-domain annotations or inference-time adaptation. Our framework is architecture-agnostic, seamlessly adapting both CNN-based and ViT-based foundation models. We evaluate our method on two challenging CT-CBCT liver segmentation benchmarks: one for interventional vascular procedures and one for radiation therapy, demonstrating that even large-scale pretrained segmentation networks require explicit feature-space bridging to generalize across acquisition modalities, and that our approach consistently outperforms existing pretrained foundation model and UDA strategies. To support reproducibility and benchmarking, we release the liver segmentations for a public CBCT dataset, along with the code, trained models, and weights.
Gauthier Miralles, Loic Le Folgoc, Vincent Jugnon +1
LTCI, Télécom Paris, Institut Polytechnique de Paris, Palaiseau, France · GE HealthCare, Buc, France
Supervised synthetic CT (sCT) generation is commonly trained and evaluated as voxel-wise regression against registered reference CT images. In practice, MRI-CT and CBCT-CT pairs are aligned through registration procedures that leave residual misalignments. These residuals are not independent intensity noise but spatially coherent geometric discrepancies that act as structured label noise. We investigate how this registration-induced bias affects supervised MRI-to-CT and CBCT-to-CT synthesis on 1,784 paired patients covering five anatomical regions. Voxel-wise scores strongly depend on the consistency between the registration used to build the training targets and the one used for evaluation: models score best when both conventions match, showing that networks partly learn the geometric convention of the registration pipeline and that standard metrics reward it. Training on more anatomically consistent registrations reduces prediction variability and improves out-of-distribution robustness, and CT-only controls show that registration alone produces metric errors in the range of top challenge submissions. To mitigate the limits of voxel-wise supervision, we introduce a perceptual loss computed in the feature space of a pretrained Segment Anything encoder. Compared with MAE-only and VGG-based objectives, it improves downstream segmentation and yields sharper, more structurally coherent sCT. Perceptual and voxel-wise metrics disagree under imperfect alignment and agree when the evaluation geometry is reliable. These results identify registration-induced bias as a central confounder in supervised sCT generation and argue for complementing voxel-wise agreement with anatomy-oriented evaluation criteria.