Structured clinical decisions from volumetric computed tomography (CT) require anatomically grounded predictions and calibrated confidence estimates. However, existing 3D medical multimodal models often suffer from uncalibrated autoregressive decoding and shortcut reliance on irrelevant anatomical regions. We introduce Radev, a decision-native multimodal model that integrates anatomy-guided visual compression, direct candidate prediction, and counterfactual confidence supervision. To bridge global context with fine-grained slice details, a frozen 3D encoder extracts reusable organ-level features, which are dynamically selected by the query to attend to 2D slice features within predicted anatomical bounds. The resulting compact visual tokens enable the language backbone to estimate candidate probabilities in a single forward pass without autoregressive decoding. We further propose Counterfactual-Calibrated Training (CCT) to compare predictions under intact and intervened organ representations. CCT encourages confidence to decrease when removing target-organ evidence degrades decision quality, while penalizing excessive confidence drops under unrelated-organ removal. To facilitate rigorous evaluation, we construct CT-Verdict, a comprehensive benchmark spanning binary finding presence, multiple-choice questions, and ordinal severity assessment across both in-distribution and external cohorts. Extensive experiments demonstrate that Radev significantly outperforms state-of-the-art methods in both decision accuracy and confidence calibration, while generalizing robustly under distribution shifts. Project page at https://juntaojianggavin.github.io/projects/Radev/ .
Figures & tables
Figure 1: Generative VLMs vs. Decision-Native VLMs. Conventional generative VLMs are designed for open-ended reasoning and report generation, yet often rely on ungrounded visual context and yield uncalibrated confidence. Radev is a decision-native model tailored for structured, organ-grounded, and confidence-aware clinical judgment.
Figure 2: Framework of the proposed Radev. (a) The Organ-Grounded Visual Encoder uses organ masks and learned mask queries to extract 3D organ tokens. Question-selected organ tokens attend to 2D slice features within their anatomical bounds. The language backbone and candidate scoring head predict an answer distribution in a single forward pass. (b) Training proceeds through projector–evidence alignment, verdict fine-tuning, and Counterfactual-Calibrated Training (CCT). (c) CCT constructs factual, target-ablated, control-ablated, and evidence-blind views by intervening on visual features. The first three views receive task supervision, while the evidence-blind view receives a confidence-margin penalty.
Model
Noul
Choice
Score
Acc ↑
mBAcc ↑
mAUC ↑
ECE ↓
Brier ↓
Acc ↑
mBAcc ↑
mAUC ↑
ECE ↓
Brier ↓
MAE ↓
KRPS ↓
QWK ↑
ECE ↓
Brier ↓
General VLMs
LLaVA-Med-7B ( Li et al., 2023 )
39.94
50.61
61.31
0.35
0.71
19.69
49.82
50.15
0.42
1.05
0.75
0.14
0.15
0.19
0.93
RadFM ( Wu et al., 2025 )
58.88
50.03
51.72
0.11
0.47
39.36
49.92
50.42
0.25
0.89
0.93
0.21
0.07
0.54
1.19
CT-Chat ( Hamamci et al., 2026 )
41.92
50.09
52.07
0.34
0.71
22.30
50.21
52.22
0.41
1.11
0.96
0.18
-0.08
0.46
1.03
M3D-Phi3-4B ( Bai et al., 2024 )
47.48
54.55
57.85
0.50
1.01
9.71
50.01
50.95
0.85
1.72
0.99
0.21
0.11
0.51
1.13
Table 1: Comparison of representative general and medical VLMs on the CT-Verdict-IID . Accuracy (Acc.) is per-question exact-match accuracy. mBAcc and mAUC are macro means over the finding diseases. Score MAE, KRPS, and QWK are computed over levels 0–4. Bold marks the best result in each column and underline the runner-up.
Model
Noul
Choice
Score
Acc ↑
mAUC ↑
Acc ↑
mAUC ↑
MAE ↓
KRPS ↓
General VLMs
LLaVA-Med-7B ( Li et al., 2023 )
35.80
55.80
17.60
58.50
0.653
0.152
RadFM ( Wu et al., 2025 )
55.70
43.50
55.40
46.00
0.582
0.130
CT-Chat ( Hamamci et al., 2026 )
40.00
39.70
8.90
51.30
1.440
0.229
M3D-Llama2-7B ( Bai et al., 2024 )
41.80
53.10
15.70
51.40
0.993
0.222
Table 2: Comparison of representative general and medical VLMs on the CT-Verdict-OOD .
Model
Clinical tasks
IID
OOD
DD
OAD
SG
AT
LA
Acc
mAUC
Acc
mAUC
Merlin-ZS
✓
×
×
×
×
66.00
79.80
63.23
71.67
RADAR
✓
×
×
×
×
66.73
80.10
60.50
74.71
Radev-2B
✓
✓
✓
✓
✓
90.08
87.79
72.72
77.61
Table 3: Comparison of Radev with SOTA methods on the diagnosis tasks from CT-Verdict-IID and CT-Verdict-OOD . DD denotes disease discrimination, OAD organ abnormality diagnosis, SG severity grading, AT acute triage, and LA laterality assessment. ✓ indicates supported and × indicates unsupported.
Figure 3: Reliability resolution analysis. Each point represents a model plotted by its reliability error (REL) and resolution (RES), computed from the binned Murphy decomposition of the top-label Brier score. The dashed line marks the RES=REL boundary.
Figure 4: Accuracy under confidence-based rejection. Samples are rejected in ascending order of predictive confidence. The rejection rate is the percentage of all samples rejected, and accuracy is computed over the retained samples.
Varian t
2D Slices
Noul
Choice
Score
Acc ↑
mAUC ↑
Acc ↑
mAUC ↑
MAE ↓
KRPS ↓
2D encoder
16
83.20
69.07
63.63
62.49
0.43
0.07
2D encoder
32
83.10
67.21
62.85
60.83
0.43
0.07
3D encoder
0
88.11
83.10
67.52
77.40
0.41
0.07
token concat
32
88.69
84.19
68.29
77.03
0.41
0.07
w/o grounding
32
89.33
85.95
69.51
80.36
0.39
0.06
Table 4: Ablation study for the vision encoder architecture of Radev-2B after VFT on the CT-Verdict-IID .
Model
Noul
Choice
Score
Acc ↑
mAUC ↑
Acc ↑
mAUC ↑
MAE ↓
KRPS ↓
Qwen3.5-2B ( Qwen Team, 2026 )
83.10
67.21
62.85
60.83
0.43
0.07
Qwen3.5-4B ( Qwen Team, 2026 )
82.96
67.45
62.93
61.42
0.43
0.07
ClinFusion-8B ( Yuan et al., 2026 )
80.36
51.23
59.34
50.20
0.46
0.07
Radev-2B-VFT (ours)
89.91
87.89
70.30
81.41
0.39
0.06
Table 5: Comparison results of Radev-2B-VFT and baselines after VFT in the same training configurations on the CT-Verdict-IID .
Align
VFT
CCT
Noul
Choice
Score
Acc ↑
mAUC ↑
Acc ↑
mAUC ↑
MAE ↓
KRPS ↓
✓
×
×
86.93
80.78
66.15
72.27
0.46
0.07
×
✓
×
88.93
85.50
68.26
77.65
0.40
0.06
✓
✓
×
89.91
87.89
70.30
81.41
0.39
0.06
✓
✓
✓
90.08
87.79
71.33
81.91
0.39
0.06
Table 6: Ablation study for the training stages of Radev-2B on the CT-Verdict-IID , evaluated at both the accuracy (top) and calibration (bottom, ×100 ) levels.
Variant
Noul
Choice
Score
REL ↓
RES ↑
ECE ↓
REL ↓
RES ↑
ECE ↓
REL ↓
RES ↑
ECE ↓
continue VFT
0.09
33.52
0.99
0.79
23.65
3.13
0.71
18.46
4.17
+ multi-view
0.05
33.54
1.15
0.66
23.63
3.45
0.45
18.17
3.07
+ all-view sup.
0.02
33.40
0.60
0.56
23.56
2.26
0.38
18.34
2.20
+ blind view & hinge
0.02
33.39
0.57
0.55
23.58
2.09
0.35
18.25
2.04
Table 7: CCT ablation on the CT-Verdict-IID to evaluate calibration (Murphy decomposition, ×100 ).
Appendix figures & tables6 assets
Supplementary material from the paper’s appendix.
Appendix
Figure A1 : Overview of CT-Verdict. (a) Benchmark construction process: radiology reports are parsed into structured findings; synthesis rules over presence, attributes, and relations turn each finding into candidate questions; questions are generated deterministically and their labels verified by three LLM readers with human spot-checking; finally, a study-level split separates training from test. (b) Examples of the three question types: binary presence (noul), multi-way choice, and ordinal severity (score). (c) Details of dataset: distributions of question types and clinical tasks, dataset splits, and organ/disease coverage.
Organ / Region
Train
IID
OOD
Liver / biliary tree
33,483 (15.0%)
8,568 (15.1%)
248 (12.1%)
Lower thorax
33,427 (15.0%)
8,414 (14.8%)
0 (0.0%)
Kidneys / ureters
32,937 (14.8%)
8,308 (14.6%)
381 (18.5%)
Gastrointestinal tract
30,443 (13.6%)
7,540 (13.3%)
197 (9.6%)
Gallbladder
24,295 (10.9%)
6,041 (10.6%)
143 (7.0%)
Peritoneal cavity
21,454 (9.6%)
5,494 (9.7%)
316 (15.4%)
Appendix
Table A1: Distribution of major anatomical organ/region categories across the training, IID test, and OOD test splits. Values are n (%).
Clinical capability
Train
IID
OOD
Disease discrimination
138,828 (62.2%)
35,265 (62.1%)
1,194 (58.1%)
Organ abnormality
47,836 (21.4%)
12,178 (21.4%)
769 (37.4%)
Severity grading
10,521 (4.7%)
2,690 (4.7%)
59 (2.9%)
Acute triage
3,963 (1.8%)
1,034 (1.8%)
0 (0.0%)
Laterality assessment
984 (0.4%)
259 (0.5%)
0 (0.0%)
Other
21,154 (9.5%)
5,399 (9.5%)
33 (1.6%)
Appendix
Table A2: Distribution of clinical task capabilities across the training, IID test, and OOD test splits. Values are n (%). Each question carries one capability label; “Other” groups fine-grained attribute questions, and percentages use each split’s total.
Disease / Finding
Train
IID
OOD
Atelectasis
13,687 (9.1%)
3,434 (9.0%)
0 (0.0%)
Gallstones
12,096 (8.0%)
2,996 (7.8%)
59 (4.7%)
Renal hypodensities
9,594 (6.4%)
2,370 (6.2%)
110 (8.8%)
Biliary ductal dilation
9,443 (6.3%)
2,492 (6.5%)
82 (6.5%)
Surgically absent gallbladder
9,392 (6.2%)
2,298 (6.0%)
33 (2.6%)
Bowel obstruction
9,063 (6.0%)
2,240 (5.9%)
35 (2.8%)
Appendix
Table A3: Question counts and shares across the 30 annotated diseases/findings in the training (150,333 disease-tagged items), IID test (38,214 items), and OOD test (1,253 items) splits, counting only disease-tagged questions. Values are n (%).
Metric
CT-Verdict-IID
CT-Verdict-OOD
Audited report units
82,836
613
Base-reader consensus
79,494 (96.0%)
567 (92.5%)
Adjudicated units
1,854
19
Adjudication retained
1,564
9
Inter-reader agreement
97.8%
96.7%
Appendix
Table A4: Multi-reader verification statistics on audited finding-presence units.
Figure A2 : Qualitative verdicts on CT-Verdict-IID and CT-Verdict-OOD. Each row shows one axial slice, the full dataset question with its gold label, and the verdicts of GPT-5.4 (free-text), Jev-1.14 (likelihood head), and Radev-2B (ours). Rows (a) and (b) are successes of Radev on IID and OOD respectively; row (c) is a failure shared by all three models, on which Radev reports the lowest confidence.