Confidence-Based Adaptive Retrieval Fails Where It Matters Most: A Paradox in Biomedical Question Answering
Authors: Chengying She, Siyu Deng, Haiyan Ge, Lizhuang Liu
Organizations: Shanghai Advanced Research Institute, Chinese Academy of Sciences University of Chinese Academy of Sciences, Shanghai, China · Department of Respiratory and Critical Care Medicine, Huadong Hospital Fudan University, Shanghai, China
Large language models (LLMs) are increasingly used for biomedical question answering, but plausible incorrect answers remain a safety risk in clinical settings. Retrieval-augmented generation (RAG) can ground responses in medical literature, while confidence-based adaptive RAG retrieves only when the model appears uncertain. We evaluate this routing strategy on three biomedical QA benchmarks of increasing difficulty and compare models across a broad range of parameter scales. The results reveal a paradox: confidence is well calibrated (AUROC 0.78--0.89) on standard medical exam questions where retrieval adds little value (+2.4% to -1.4%), yet becomes near-random (AUROC 0.506) on specialist-level questions where retrieval helps most (+11.2%). Five uncertainty signals---first-token probability, margin, entropy, consistency-based sampling, and verbalized confidence---show the same failure pattern. Five post-hoc calibration correction strategies, including density-ratio reweighting and rank-preserving transformation, do not recover a useful routing signal on hard questions (best AUROC: 0.507). Cross-model comparison shows that larger parameter scale and higher base accuracy do not guarantee reliable confidence-based routing under specialist-domain difficulty shift. These findings challenge the premise of confidence-based adaptive RAG: in high-stakes biomedical settings, defaulting to always-retrieve is safer and more accurate than confidence-based routing when calibration on the target domain is unknown.
Figures & tables
Fig. 1: The confidence–retrieval paradox across three biomedical QA benchmarks. Retrieval value ( Δ , x-axis) and confidence AUROC (y-axis) are inversely correlated. On MedXpertQA (red), retrieval provides the largest gain yet confidence is near-random.
Dataset
No-RAG
Always
Δ
AUROC
H/H
MedQA
72.2
74.6
+2.4
0.781
23/17
MMLU-Pro
80.8
79.4
−1.4
0.891
11/13
MedXpertQA
14.8
26.0
+11.2
0.506
66/13
TABLE I: Cross-dataset comparison of retrieval effectiveness and confidence calibration. Δ = Always − No-RAG (retrieval value). AUROC = margin signal predicting answer correctness. H/H = retrieval Help/Hurt counts. The inverse relationship between Δ and AUROC reveals the paradox.
Signal
AUROC
Adapt. ACC
Max Probability
0.394
17.5%
Margin
0.391
17.5%
Entropy
0.390
17.5%
Consistency ( N=5 )
0.522
17.5%
Verbalized (1–5)
0.391
19.0%
Random baseline
—
19.4%
TABLE II: Multi-signal ablation on MedXpertQA (200 samples). All signals are at or below random (AUROC 0.5). Random retrieval (19.4%) outperforms all adaptive strategies; always-retrieve (27.0%) provides a substantial margin.
Signal
MedQA
MMLU-Pro
MedXpert
Max Prob.
0.78
0.82
0.46
Margin
0.79
0.83
0.45
Entropy
0.77
0.81
0.47
TABLE III: AUROC of three confidence signals. Calibration degrades as retrieval value increases.
Fig. 2: Visual overview of confidence signal behavior. (a) First-token signals show a consistent degradation pattern from easy to hard datasets. (b) On MedXpertQA, all signals deviate minimally from random (0.5); first-token signals are anti-predictive while consistency barely exceeds chance. Exact values in Table III and Table II .
Method
MedQA
MedXpert
MMLU-Pro
Raw margin
0.781
0.506
0.891
Inverted margin
0.219
0.494
0.109
Rank-corrected
0.781
0.506
0.891
DR-weighted
0.781
0.503
0.160
DACC (full)
0.781
0.507
0.892
TABLE IV: AUROC of corrected confidence signals on three datasets. No method meaningfully improves routing on MedXpertQA (best: 0.507 vs. 0.506 raw). On MedQA and MMLU-Pro, methods either preserve or destroy the existing signal.
Method
Best τ
Best ACC
Retrieval %
Raw margin
1.00
26.0%
100%
Inverted
1.00
26.0%
100%
Rank-corrected
1.00
26.0%
100%
DR-weighted
1.00
26.0%
100%
DACC (full)
1.00
26.0%
100%
Never Retrieve
—
14.8%
0%
TABLE V: Adaptive retrieval results on MedXpertQA with corrected signals. All methods converge to “always retrieve” as the optimal strategy ( τ=1.00 , 100% retrieval), confirming the corrected signals provide no useful routing information.
Fig. 3: Effect of calibration correction, shown as Δ AUROC (corrected minus raw margin). In panel (a), solid blue denotes MedQA and hatched green denotes MMLU-Pro. Inversion destroys the signal on easier datasets, while all methods produce negligible change on MedXpertQA (best: +0.001), confirming signal absence rather than miscalibration. Exact AUROC values in Table IV .
Fig. 4: Cross-model verification across five models (DashScope API, verbalized confidence, 200 samples per dataset). Panels show no-RAG accuracy (a) and confidence AUROC (b). On MedXpertQA—the hardest dataset—DeepSeek-V4-Pro exhibits anti-predictive confidence (AUROC 0.408 < 0.5), while Kimi-K2.6 and MiniMax-M2.5 hover near chance (AUROC ≈ 0.5). Qwen3.7-Plus retains the best calibration overall but sees AUROC drop from 0.869 (MedQA) to 0.614 (MedXpertQA). See Table VI for exact values.
Model
Params
Metric
MedQA
MMLU-Pro
MedXpert
Qwen3.7-Plus
397B
No-RAG ACC (%)
94.5
93.5
57.5
Confidence AUROC
0.869
0.649
0.614
DeepSeek-V4-Pro
1.6T
No-RAG ACC (%)
96.0
90.0
41.0
Confidence AUROC
0.542
0.485
0.408
Kimi-K2.6
1T
No-RAG ACC (%)
91.0
92.0
30.5
Confidence AUROC
0.461
0.529
0.493
TABLE VI: Cross-model comparison using verbalized confidence (DashScope API, 200 samples per dataset). No-RAG accuracy and confidence AUROC are reported for each model. On standard datasets, larger models achieve high accuracy and moderate-to-strong calibration; on specialist-level MedXpertQA, confidence degrades to near-random for most models, confirming the paradox is not model-specific.