cs.CVNov 24, 2026

Anatomy-Aware Pseudo-Labels and Homotopy-Annealed Hausdorff Supervision for Semi-Supervised Pancreas Segmentation

Authors: Alireza Kheyrkhah, Amir Hossein Saleknia, Reza Azad, Sina Houshmand, Dorit Merhof, Ulas Bagci, Alaa Sulaiman

Organizations: Independent Researcher · University of Regensburg, Germany · University of California San Francisco, USA · Northwestern University, USA · 

Abstract

Confidence-gated co-training assumes that pseudo-label errors are uncertain and concentrated at organ boundaries. We argue that for pancreas CT, where the target organ is a single connected structure and detached fragments are anatomically implausible, the dominant failures arise at three levels: where the organ is, what its boundary should look like, and how a correct boundary is penalized. Anatomical Rectification relabels implausible fragments of a teacher prediction as confident background, without adding any loss or parameter; an audit confirms that its rejections are overwhelmingly detached hallucinations and that thin, tail-like slices are not eroded. Boundary Grafting transplants labelled surface regions with their annotation into unlabeled volumes, replacing unreliable boundary pseudo-labels with ground truth. The residual error is coherent surface displacement, weakly penalized by permutation-invariant Dice and cross-entropy losses. Homotopy-Annealed Hausdorff (HAH) supervision anneals a distance-weighted penalty from an annotation-anchored objective that is convex in the prediction to a Hausdorff surrogate, admitting the prediction-dependent distance term only after the predicted surface becomes reliable. On NIH pancreas CT, under the standard semi-supervised split, the full method reaches 84.60% Dice and 4.97 voxels 95HD, improving all four metrics over compared methods; on MSD Task07, 78.90% Dice and 4.19 voxels 95HD. We further contribute PanTS-SSL, a semi-supervised evaluation protocol derived from the public 9,901-case PanTS corpus, with a curated 1,015-volume main pool, labelled tiers of 50, 100 and 250 volumes, an 80-case tumor track, shift probes for acquisition and anatomy change, and a fixed 901-volume test set. On it, the method exceeds the co-training baseline at 100 labels, scales to 85.29% Dice at 250 labels, and reaches 85.50% Dice at 100 labels with HAH.

Figures & tables

Explore similar work

CardsList
  1. SCKAN: Structural Consensus-based KAN Prototype Learning for Semi-Supervised Pancreas Segmentation

    May 26, 2026Yuqi Liu, Yufei Chen, Wei Fu +2Prototype LearningMedical Image Segmentation

  2. Segment Anything Pancreas: A Unified MRI Segmentation Model for Pancreatic Cancer Radiotherapy

    Oct 29, 2026Zach Eidex, Mojtaba Safari, Kundan Thind +3Medical Image Segmentation3D Medical Image Segmentation

  3. CoDiR: Confidence-Guided Diffusion Refinement for Semi-Supervised Histopathology Segmentation

    Aug 12, 2026Hoai Nhan Pham, Dang-Nguyen Bui, Le-Van Thai +7Histopathology Image SegmentationSemi-Supervised Medical Image Segmentation