Tool use learned during supervised fine-tuning (SFT) is not always retained during reinforcement learning (RL). We study how properties of SFT data may affect this retention by constructing Low, Medium, and High SFT datasets with approximately matched token budgets but different tool-call depths. Under the same RL recipe, the three initializations reach similar RL training accuracy yet exhibit markedly different tool-use dynamics: tool initiation increases in Low, declines in Medium, and collapses in High. We observe that these datasets also differ substantially in the amount of reasoning preceding each tool call. In particular, High trajectories contain considerably less pre-call reasoning, motivating the hypothesis that pre-call reasoning may affect how well tool use is calibrated and, consequently, whether the corresponding behaviors are retained during RL. An idealized theoretical analysis provides a selective-retention view of this process: advantages in overall and tool-conditioned accuracy can be preserved under outcome-only optimization, while tool initiation increases only when tool-using trajectories are more successful than the tool-free alternative. Guided by this analysis, we rank the original High trajectories by average pre-call reasoning length and retain the highest-ranked examples while approximately matching cumulative SFT token exposure. This simple filtering strategy improves post-RL accuracy and tool-conditioned final-answer success without consistently increasing tool initiation across multiple benchmarks. These results suggest that pre-call reasoning is a useful dimension of SFT supervision for understanding and improving tool-use retention under downstream RL.
Figures & tables
Figure 1: RL training accuracy
Checkpoint
Tool-on Acc
Tool-off Acc
Gain
Tool initiation rate
Conditional tool-call depth
Low SFT
59.34
59.65
-0.31
67.72
1.21
Low RL
67.67
67.66
+0.02
75.04
1.32
Medium SFT
47.43
62.14
-14.71
58.50
3.98
Medium RL
67.66
70.56
-2.90
20.82
3.03
High SFT
43.45
63.52
-20.07
50.60
5.59
High RL
66.24
68.90
-2.66
5.38
6.32
Table 1: Evaluation results for the SFT and RL checkpoints of Low , Medium , and High . Accuracy is pooled over five evaluation benchmarks. Gain denotes the difference between tool-on and tool-off accuracy. The three initializations exhibit similar final tool-on accuracy but critically different tool-use behavior (Figure 4 ).
Figure 5: Mean pre-call tokens in SFT
Method
V*Bench
ChartQA
MathVista
WeMath
CharXiv
Overall
High
84.29
85.48
65.10
57.30
31.40
66.24
LF50
84.82
85.36
67.70
58.79
37.20
67.92
LF25
86.91
87.72
68.90
60.57
38.40
69.75
Random25
81.68
82.20
66.90
60.34
35.80
66.67
Matched-Random25
85.34
87.16
67.40
57.14
38.80
68.39
Total-Reasoning25
76.44
83.56
66.20
54.57
34.30
65.15
Table 2: Final tool-on accuracy (%) after RL. LF25 and LF50 select tool-using demonstrations by mean pre-call reasoning length. The numbers 25 and 50 denote the percentage of the original High assistant-supervised token budget retained per epoch. The rows below the horizontal rule report the random-selection, total-reasoning-length, and pre-call truncation experiments discussed in Q1–Q3 of Section 4.3 . Overall is pooled accuracy across all five benchmarks. Bold marks column bests. Shading highlights LF25.
Figure 8: A qualitative ChartQA example illustrating how reasoning before a Code call can determine the computational target. In the original High trace, the model incorrectly treats the 4G revenue (540) as the total 2024 revenue, leading the subsequent code to use the wrong denominator. In contrast, the Length-Filtered model correctly sums the revenues of all four generations to obtain 815, yielding the correct percentage of 92.02%.
Figure 9: The final accuracy of the tool-using trajectories
Initialization
V*Bench
ChartQA
MathVista
WeMath
CharXiv
Overall
Original High
-1.57
-2.08
-1.80
-3.68
-3.40
-2.66
LF25
+5.23
+1.00
+1.30
+1.37
+0.40
+1.18
Table 3: Tool-availability gain, measured as tool-on minus tool-off accuracy in percentage points. Positive values indicate higher accuracy with tools available.
Benchmark
Stage
Init.
First-call justification
Appropriate tool and arguments
Correct use of successful Code outputs
MathVista
SFT
High
31.2
33.3
7.7
LF25
34.4
34.9
16.0
RL
High
62.5
21.5
41.9
LF25
46.9
35.5
71.3
WeMath
SFT
High
28.1
37.6
64.3
LF25
46.9
42.9
72.4
Table 4: GPT-6.1-Sol behavior assessments (%). We assess justification on first calls, joint tool and argument appropriateness on all observed calls, and correct output use on successful Code calls. Bold marks the higher rate within each benchmark and stage.
Appendix figures & tables14 assets
Supplementary material from the paper’s appendix.
Appendix
Checkpoint
V*
ChartQA
MathVista
WeMath
CharXiv
Overall
Low SFT
79.06
71.80
57.90
54.89
33.60
59.34
Low RL
83.25
84.72
65.60
58.10
40.80
67.67
Medium SFT
54.97
53.96
48.80
53.05
18.50
47.43
Medium RL
85.34
83.40
66.90
62.24
35.10
67.66
High SFT
26.70
48.00
47.30
55.57
10.30
43.45
High RL
84.29
85.48
65.10
57.30
31.40
66.24
Appendix
Table 5: Tool-on accuracy (%) of the Low , Medium , and High SFT and RL checkpoints. Overall reports pooled accuracy across all 6,431 evaluation examples.
Checkpoint
V*
ChartQA
MathVista
WeMath
CharXiv
Overall
Low SFT
75.39
74.04
61.20
55.17
26.90
59.65
Low RL
83.77
86.16
69.00
56.72
36.00
67.66
Medium SFT
80.63
76.44
62.60
55.80
33.40
62.14
Medium RL
85.34
87.88
68.50
62.93
39.80
70.56
High SFT
79.58
78.20
65.10
55.46
36.20
63.52
High RL
85.86
87.56
66.90
60.98
34.80
68.90
Appendix
Table 6: Tool-off accuracy (%) of the Low , Medium , and High SFT and RL checkpoints. Overall reports pooled accuracy across all 6,431 evaluation examples.
Initialization
V*Bench
ChartQA
MathVista
WeMath
CharXiv
Overall
High
83.42 ± 1.51
86.15 ± 0.75
66.10 ± 1.05
58.22 ± 1.13
35.20 ± 3.36
67.47 ± 1.08
LF25
85.51 ± 1.32
87.56 ± 0.24
68.73 ± 0.38
59.54 ± 1.01
39.90 ± 1.31
69.58 ± 0.19
Appendix
Table 7: Post-RL tool-on accuracy (%), mean ± sample standard deviation across three seeds.
Initialization
V*Bench
ChartQA
MathVista
WeMath
CharXiv
Overall
High
83.77
86.16
65.30
50.86
40.10
66.13
LF25
84.29
88.12
68.90
58.05
39.70
69.35
Appendix
Table 8: Post-RL tool-on accuracy (%) after 64 updates.
Initialization
Start
Step 8
Step 16
Step 24
Step 32
Step 48
Step 64
High
59.80
12.34
6.29
4.92
2.11
0.20
0.12
LF25
58.48
36.02
2.89
7.11
5.20
8.79
19.10
Appendix
Table 9: Checkpoint-level tool initiation rate (%) in the extended RL run.
Initialization
V*Bench
ChartQA
MathVista
WeMath
CharXiv
Overall
High
79.06
86.28
71.70
65.71
50.50
72.67
LF25
81.68
86.84
73.70
67.05
55.10
74.35
Appendix
Table 10: Qwen3.5-4B tool-on accuracy after 32 RL updates (%).
Dataset
Mean
P0
P25
P50
P75
P100
Low
804.3
26
200
525
1,358.25
5,058
Medium
863.4
26
349.75
753.5
1,398
2,749
High
930.8
26
496
921
1,319
3,867
LF50
1,220.1
27
807
1,275
1,726.75
3,059
LF25
1,353.3
28
929
1,354.5
1,945.25
3,059
Appendix
Table 11: Distribution of assistant-supervised tokens per trajectory. P0/P100 are the minimum/maximum; P25, P50, and P75 are quantiles.